Cargando…

Correlation of Electrically Evoked Compound Action Potential Amplitude Growth Function Slope and Anamnestic Parameters in Cochlear Implant Patients—Identification of Predictors for the Neuronal Health Status

Cochlear implants (CI) are the treatment of choice in profoundly deaf patients. Measuring the electrically evoked compound action potential (ECAP) has become an important tool for verifying the function of the spiral ganglion neurons (SGN), which are the target cells of the CI stimulation. ECAP meas...

Descripción completa

Detalles Bibliográficos
Autores principales: Gärtner, Lutz, Klötzer, Katharina, Lenarz, Thomas, Scheper, Verena
Formato: Online Artículo Texto
Lenguaje:English
Publicado: MDPI 2021
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7999542/
https://www.ncbi.nlm.nih.gov/pubmed/33807687
http://dx.doi.org/10.3390/life11030203
_version_ 1783670806328377344
author Gärtner, Lutz
Klötzer, Katharina
Lenarz, Thomas
Scheper, Verena
author_facet Gärtner, Lutz
Klötzer, Katharina
Lenarz, Thomas
Scheper, Verena
author_sort Gärtner, Lutz
collection PubMed
description Cochlear implants (CI) are the treatment of choice in profoundly deaf patients. Measuring the electrically evoked compound action potential (ECAP) has become an important tool for verifying the function of the spiral ganglion neurons (SGN), which are the target cells of the CI stimulation. ECAP measurement is only possible after electrode insertion. No information about the neuronal health status is available before cochlear implantation. We investigated possible correlations between the ECAP amplitude growth function (AGF) slope and anamnestic parameters to identify possible predictors for SGN health status and therefore for CI outcome. The study included patients being implanted with various electrode array lengths. Correlation analysis was performed for the mean AGF slope of the whole array, for separate electrodes as well as for grouped electrodes of the apical, medial, and basal region, with duration of deafness, age at implantation, residual hearing (grouped for electrode length), and etiology. The mean ECAP AGF slopes decreased from apical to basal. They were not correlated to the length of the electrode array or any etiology. For the mean of the full array or when grouped for the apical, middle, and basal part, the ECAP AGF slope was negatively correlated to the duration of hearing loss and the age at implantation. Since a significant negative correlation of the ECAP AGF slope and age at cochlear implantation and duration of deafness was observed, this study supports the statement that early implantation of a CI is recommended for sensorineural hearing loss. Additional factors such as the cochlear coverage and insertion angle influence the ECAP AGF slope and performance of the patient and should be included in future multifactorial analysis to study predictive parameters for the CI outcome.
format Online
Article
Text
id pubmed-7999542
institution National Center for Biotechnology Information
language English
publishDate 2021
publisher MDPI
record_format MEDLINE/PubMed
spelling pubmed-79995422021-03-28 Correlation of Electrically Evoked Compound Action Potential Amplitude Growth Function Slope and Anamnestic Parameters in Cochlear Implant Patients—Identification of Predictors for the Neuronal Health Status Gärtner, Lutz Klötzer, Katharina Lenarz, Thomas Scheper, Verena Life (Basel) Article Cochlear implants (CI) are the treatment of choice in profoundly deaf patients. Measuring the electrically evoked compound action potential (ECAP) has become an important tool for verifying the function of the spiral ganglion neurons (SGN), which are the target cells of the CI stimulation. ECAP measurement is only possible after electrode insertion. No information about the neuronal health status is available before cochlear implantation. We investigated possible correlations between the ECAP amplitude growth function (AGF) slope and anamnestic parameters to identify possible predictors for SGN health status and therefore for CI outcome. The study included patients being implanted with various electrode array lengths. Correlation analysis was performed for the mean AGF slope of the whole array, for separate electrodes as well as for grouped electrodes of the apical, medial, and basal region, with duration of deafness, age at implantation, residual hearing (grouped for electrode length), and etiology. The mean ECAP AGF slopes decreased from apical to basal. They were not correlated to the length of the electrode array or any etiology. For the mean of the full array or when grouped for the apical, middle, and basal part, the ECAP AGF slope was negatively correlated to the duration of hearing loss and the age at implantation. Since a significant negative correlation of the ECAP AGF slope and age at cochlear implantation and duration of deafness was observed, this study supports the statement that early implantation of a CI is recommended for sensorineural hearing loss. Additional factors such as the cochlear coverage and insertion angle influence the ECAP AGF slope and performance of the patient and should be included in future multifactorial analysis to study predictive parameters for the CI outcome. MDPI 2021-03-05 /pmc/articles/PMC7999542/ /pubmed/33807687 http://dx.doi.org/10.3390/life11030203 Text en © 2021 by the authors. https://creativecommons.org/licenses/by/4.0/Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (http://creativecommons.org/licenses/by/4.0/ (https://creativecommons.org/licenses/by/4.0/) ).
spellingShingle Article
Gärtner, Lutz
Klötzer, Katharina
Lenarz, Thomas
Scheper, Verena
Correlation of Electrically Evoked Compound Action Potential Amplitude Growth Function Slope and Anamnestic Parameters in Cochlear Implant Patients—Identification of Predictors for the Neuronal Health Status
title Correlation of Electrically Evoked Compound Action Potential Amplitude Growth Function Slope and Anamnestic Parameters in Cochlear Implant Patients—Identification of Predictors for the Neuronal Health Status
title_full Correlation of Electrically Evoked Compound Action Potential Amplitude Growth Function Slope and Anamnestic Parameters in Cochlear Implant Patients—Identification of Predictors for the Neuronal Health Status
title_fullStr Correlation of Electrically Evoked Compound Action Potential Amplitude Growth Function Slope and Anamnestic Parameters in Cochlear Implant Patients—Identification of Predictors for the Neuronal Health Status
title_full_unstemmed Correlation of Electrically Evoked Compound Action Potential Amplitude Growth Function Slope and Anamnestic Parameters in Cochlear Implant Patients—Identification of Predictors for the Neuronal Health Status
title_short Correlation of Electrically Evoked Compound Action Potential Amplitude Growth Function Slope and Anamnestic Parameters in Cochlear Implant Patients—Identification of Predictors for the Neuronal Health Status
title_sort correlation of electrically evoked compound action potential amplitude growth function slope and anamnestic parameters in cochlear implant patients—identification of predictors for the neuronal health status
topic Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7999542/
https://www.ncbi.nlm.nih.gov/pubmed/33807687
http://dx.doi.org/10.3390/life11030203
work_keys_str_mv AT gartnerlutz correlationofelectricallyevokedcompoundactionpotentialamplitudegrowthfunctionslopeandanamnesticparametersincochlearimplantpatientsidentificationofpredictorsfortheneuronalhealthstatus
AT klotzerkatharina correlationofelectricallyevokedcompoundactionpotentialamplitudegrowthfunctionslopeandanamnesticparametersincochlearimplantpatientsidentificationofpredictorsfortheneuronalhealthstatus
AT lenarzthomas correlationofelectricallyevokedcompoundactionpotentialamplitudegrowthfunctionslopeandanamnesticparametersincochlearimplantpatientsidentificationofpredictorsfortheneuronalhealthstatus
AT scheperverena correlationofelectricallyevokedcompoundactionpotentialamplitudegrowthfunctionslopeandanamnesticparametersincochlearimplantpatientsidentificationofpredictorsfortheneuronalhealthstatus