Body Position Affects Capillary Blood Flow Regulation Measured with Wearable Blood Flow Sensors
In this study we demonstrate what kind of relative alterations can be expected in average perfusion and blood flow oscillations during postural changes being measured in the skin of limbs and on the brow of the forehead by wearable laser Doppler flowmetry (LDF) sensors. The aims of the study were to...
Autores principales: | , , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
MDPI
2021
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7999838/ https://www.ncbi.nlm.nih.gov/pubmed/33806328 http://dx.doi.org/10.3390/diagnostics11030436 |
_version_ | 1783670873281003520 |
---|---|
author | Fedorovich, Andrey A. Loktionova, Yulia I. Zharkikh, Elena V. Mikhailova, Maria A. Popova, Julia A. Suvorov, Alexander V. Zherebtsov, Evgeny A. |
author_facet | Fedorovich, Andrey A. Loktionova, Yulia I. Zharkikh, Elena V. Mikhailova, Maria A. Popova, Julia A. Suvorov, Alexander V. Zherebtsov, Evgeny A. |
author_sort | Fedorovich, Andrey A. |
collection | PubMed |
description | In this study we demonstrate what kind of relative alterations can be expected in average perfusion and blood flow oscillations during postural changes being measured in the skin of limbs and on the brow of the forehead by wearable laser Doppler flowmetry (LDF) sensors. The aims of the study were to evaluate the dynamics of cutaneous blood perfusion and the regulatory mechanisms of blood microcirculation in the areas of interest, and evaluate the possible significance of those effects for the diagnostics based on blood perfusion monitoring. The study involved 10 conditionally healthy volunteers (44 ± 12 years). Wearable laser Doppler flowmetry monitors were fixed at six points on the body: two devices were fixed on the forehead, on the brow; two were on the distal thirds of the right and left forearms; and two were on the distal thirds of the right and left lower legs. The protocol was used to record three body positions on the tilt table for orthostatic test for each volunteer in the following sequence: (a) supine body position; (b) upright body position (+75°); (c) tilted with the feet elevated above the head and the inclination of body axis of 15° (−15°, Trendelenburg position). Skin blood perfusion was recorded for 10 min in each body position, followed by the amplitude–frequency analysis of the registered signals using wavelet decomposition. The measurements were supplemented with the blood pressure and heart rate for every body position analysed. The results identified a statistically significant transformation in microcirculation parameters of the average level of skin blood perfusion and oscillations of amplitudes of neurogenic, myogenic and cardiac sensors caused by the postural changes. In paper, we present the analysis of microcirculation in the skin of the forehead, which for the first time was carried out in various positions of the body. The area is supplied by the internal carotid artery system and can be of particular interest for evaluation of the sufficiency of blood supply for the brain. |
format | Online Article Text |
id | pubmed-7999838 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2021 |
publisher | MDPI |
record_format | MEDLINE/PubMed |
spelling | pubmed-79998382021-03-28 Body Position Affects Capillary Blood Flow Regulation Measured with Wearable Blood Flow Sensors Fedorovich, Andrey A. Loktionova, Yulia I. Zharkikh, Elena V. Mikhailova, Maria A. Popova, Julia A. Suvorov, Alexander V. Zherebtsov, Evgeny A. Diagnostics (Basel) Article In this study we demonstrate what kind of relative alterations can be expected in average perfusion and blood flow oscillations during postural changes being measured in the skin of limbs and on the brow of the forehead by wearable laser Doppler flowmetry (LDF) sensors. The aims of the study were to evaluate the dynamics of cutaneous blood perfusion and the regulatory mechanisms of blood microcirculation in the areas of interest, and evaluate the possible significance of those effects for the diagnostics based on blood perfusion monitoring. The study involved 10 conditionally healthy volunteers (44 ± 12 years). Wearable laser Doppler flowmetry monitors were fixed at six points on the body: two devices were fixed on the forehead, on the brow; two were on the distal thirds of the right and left forearms; and two were on the distal thirds of the right and left lower legs. The protocol was used to record three body positions on the tilt table for orthostatic test for each volunteer in the following sequence: (a) supine body position; (b) upright body position (+75°); (c) tilted with the feet elevated above the head and the inclination of body axis of 15° (−15°, Trendelenburg position). Skin blood perfusion was recorded for 10 min in each body position, followed by the amplitude–frequency analysis of the registered signals using wavelet decomposition. The measurements were supplemented with the blood pressure and heart rate for every body position analysed. The results identified a statistically significant transformation in microcirculation parameters of the average level of skin blood perfusion and oscillations of amplitudes of neurogenic, myogenic and cardiac sensors caused by the postural changes. In paper, we present the analysis of microcirculation in the skin of the forehead, which for the first time was carried out in various positions of the body. The area is supplied by the internal carotid artery system and can be of particular interest for evaluation of the sufficiency of blood supply for the brain. MDPI 2021-03-04 /pmc/articles/PMC7999838/ /pubmed/33806328 http://dx.doi.org/10.3390/diagnostics11030436 Text en © 2021 by the authors. https://creativecommons.org/licenses/by/4.0/Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (http://creativecommons.org/licenses/by/4.0/ (https://creativecommons.org/licenses/by/4.0/) ). |
spellingShingle | Article Fedorovich, Andrey A. Loktionova, Yulia I. Zharkikh, Elena V. Mikhailova, Maria A. Popova, Julia A. Suvorov, Alexander V. Zherebtsov, Evgeny A. Body Position Affects Capillary Blood Flow Regulation Measured with Wearable Blood Flow Sensors |
title | Body Position Affects Capillary Blood Flow Regulation Measured with Wearable Blood Flow Sensors |
title_full | Body Position Affects Capillary Blood Flow Regulation Measured with Wearable Blood Flow Sensors |
title_fullStr | Body Position Affects Capillary Blood Flow Regulation Measured with Wearable Blood Flow Sensors |
title_full_unstemmed | Body Position Affects Capillary Blood Flow Regulation Measured with Wearable Blood Flow Sensors |
title_short | Body Position Affects Capillary Blood Flow Regulation Measured with Wearable Blood Flow Sensors |
title_sort | body position affects capillary blood flow regulation measured with wearable blood flow sensors |
topic | Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7999838/ https://www.ncbi.nlm.nih.gov/pubmed/33806328 http://dx.doi.org/10.3390/diagnostics11030436 |
work_keys_str_mv | AT fedorovichandreya bodypositionaffectscapillarybloodflowregulationmeasuredwithwearablebloodflowsensors AT loktionovayuliai bodypositionaffectscapillarybloodflowregulationmeasuredwithwearablebloodflowsensors AT zharkikhelenav bodypositionaffectscapillarybloodflowregulationmeasuredwithwearablebloodflowsensors AT mikhailovamariaa bodypositionaffectscapillarybloodflowregulationmeasuredwithwearablebloodflowsensors AT popovajuliaa bodypositionaffectscapillarybloodflowregulationmeasuredwithwearablebloodflowsensors AT suvorovalexanderv bodypositionaffectscapillarybloodflowregulationmeasuredwithwearablebloodflowsensors AT zherebtsovevgenya bodypositionaffectscapillarybloodflowregulationmeasuredwithwearablebloodflowsensors |