Cargando…

A Sample-In-Answer-Out Microfluidic System for the Molecular Diagnostics of 24 HPV Genotypes Using Palm-Sized Cartridge

This paper proposes an automated microfluidic system for molecular diagnostics that integrates the functions of a traditional polymerase chain reaction (PCR) laboratory into a palm-sized microfluidic cartridge (CARD) made of polystyrene. The CARD integrates 4 independent microfluidic sample lanes, w...

Descripción completa

Detalles Bibliográficos
Autores principales: Wang, Rui, Wu, Jing, He, Xiaodong, Zhou, Peng, Shen, Zuojun
Formato: Online Artículo Texto
Lenguaje:English
Publicado: MDPI 2021
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8000143/
https://www.ncbi.nlm.nih.gov/pubmed/33806512
http://dx.doi.org/10.3390/mi12030263
_version_ 1783670936503844864
author Wang, Rui
Wu, Jing
He, Xiaodong
Zhou, Peng
Shen, Zuojun
author_facet Wang, Rui
Wu, Jing
He, Xiaodong
Zhou, Peng
Shen, Zuojun
author_sort Wang, Rui
collection PubMed
description This paper proposes an automated microfluidic system for molecular diagnostics that integrates the functions of a traditional polymerase chain reaction (PCR) laboratory into a palm-sized microfluidic cartridge (CARD) made of polystyrene. The CARD integrates 4 independent microfluidic sample lanes, which can independently complete a sample test, and each sample lane integrates the 3 functional areas of the sample preparation area, PCR amplification area, and product analysis area. By using chemical cell lysis, magnetic silica bead-based DNA extraction, combined with multi-PCR-reverse dot hybridization with microarray, 24 HPV genotypes can be typing tested in CARD. With a custom-made automated CARD operating platform, the entire process can be automatically carried out, achieving sample-in-answer-out. The custom-made operation platform is developed based on a liquid handling station-type, which can automatically load off-chip reagents without placing reagents in CARD in advance. The platform can control six CARDs to work simultaneously, detect 24 samples at a time. The results show that the limit of detection of the microfluidic system is 200 copies/test, and the positive detection rate of clinical samples by this system is 100%, which is an effective method for detection of HPV.
format Online
Article
Text
id pubmed-8000143
institution National Center for Biotechnology Information
language English
publishDate 2021
publisher MDPI
record_format MEDLINE/PubMed
spelling pubmed-80001432021-03-28 A Sample-In-Answer-Out Microfluidic System for the Molecular Diagnostics of 24 HPV Genotypes Using Palm-Sized Cartridge Wang, Rui Wu, Jing He, Xiaodong Zhou, Peng Shen, Zuojun Micromachines (Basel) Article This paper proposes an automated microfluidic system for molecular diagnostics that integrates the functions of a traditional polymerase chain reaction (PCR) laboratory into a palm-sized microfluidic cartridge (CARD) made of polystyrene. The CARD integrates 4 independent microfluidic sample lanes, which can independently complete a sample test, and each sample lane integrates the 3 functional areas of the sample preparation area, PCR amplification area, and product analysis area. By using chemical cell lysis, magnetic silica bead-based DNA extraction, combined with multi-PCR-reverse dot hybridization with microarray, 24 HPV genotypes can be typing tested in CARD. With a custom-made automated CARD operating platform, the entire process can be automatically carried out, achieving sample-in-answer-out. The custom-made operation platform is developed based on a liquid handling station-type, which can automatically load off-chip reagents without placing reagents in CARD in advance. The platform can control six CARDs to work simultaneously, detect 24 samples at a time. The results show that the limit of detection of the microfluidic system is 200 copies/test, and the positive detection rate of clinical samples by this system is 100%, which is an effective method for detection of HPV. MDPI 2021-03-04 /pmc/articles/PMC8000143/ /pubmed/33806512 http://dx.doi.org/10.3390/mi12030263 Text en © 2021 by the authors. https://creativecommons.org/licenses/by/4.0/Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (http://creativecommons.org/licenses/by/4.0/ (https://creativecommons.org/licenses/by/4.0/) ).
spellingShingle Article
Wang, Rui
Wu, Jing
He, Xiaodong
Zhou, Peng
Shen, Zuojun
A Sample-In-Answer-Out Microfluidic System for the Molecular Diagnostics of 24 HPV Genotypes Using Palm-Sized Cartridge
title A Sample-In-Answer-Out Microfluidic System for the Molecular Diagnostics of 24 HPV Genotypes Using Palm-Sized Cartridge
title_full A Sample-In-Answer-Out Microfluidic System for the Molecular Diagnostics of 24 HPV Genotypes Using Palm-Sized Cartridge
title_fullStr A Sample-In-Answer-Out Microfluidic System for the Molecular Diagnostics of 24 HPV Genotypes Using Palm-Sized Cartridge
title_full_unstemmed A Sample-In-Answer-Out Microfluidic System for the Molecular Diagnostics of 24 HPV Genotypes Using Palm-Sized Cartridge
title_short A Sample-In-Answer-Out Microfluidic System for the Molecular Diagnostics of 24 HPV Genotypes Using Palm-Sized Cartridge
title_sort sample-in-answer-out microfluidic system for the molecular diagnostics of 24 hpv genotypes using palm-sized cartridge
topic Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8000143/
https://www.ncbi.nlm.nih.gov/pubmed/33806512
http://dx.doi.org/10.3390/mi12030263
work_keys_str_mv AT wangrui asampleinansweroutmicrofluidicsystemforthemoleculardiagnosticsof24hpvgenotypesusingpalmsizedcartridge
AT wujing asampleinansweroutmicrofluidicsystemforthemoleculardiagnosticsof24hpvgenotypesusingpalmsizedcartridge
AT hexiaodong asampleinansweroutmicrofluidicsystemforthemoleculardiagnosticsof24hpvgenotypesusingpalmsizedcartridge
AT zhoupeng asampleinansweroutmicrofluidicsystemforthemoleculardiagnosticsof24hpvgenotypesusingpalmsizedcartridge
AT shenzuojun asampleinansweroutmicrofluidicsystemforthemoleculardiagnosticsof24hpvgenotypesusingpalmsizedcartridge
AT wangrui sampleinansweroutmicrofluidicsystemforthemoleculardiagnosticsof24hpvgenotypesusingpalmsizedcartridge
AT wujing sampleinansweroutmicrofluidicsystemforthemoleculardiagnosticsof24hpvgenotypesusingpalmsizedcartridge
AT hexiaodong sampleinansweroutmicrofluidicsystemforthemoleculardiagnosticsof24hpvgenotypesusingpalmsizedcartridge
AT zhoupeng sampleinansweroutmicrofluidicsystemforthemoleculardiagnosticsof24hpvgenotypesusingpalmsizedcartridge
AT shenzuojun sampleinansweroutmicrofluidicsystemforthemoleculardiagnosticsof24hpvgenotypesusingpalmsizedcartridge