A Sample-In-Answer-Out Microfluidic System for the Molecular Diagnostics of 24 HPV Genotypes Using Palm-Sized Cartridge
This paper proposes an automated microfluidic system for molecular diagnostics that integrates the functions of a traditional polymerase chain reaction (PCR) laboratory into a palm-sized microfluidic cartridge (CARD) made of polystyrene. The CARD integrates 4 independent microfluidic sample lanes, w...
Autores principales: | , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
MDPI
2021
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8000143/ https://www.ncbi.nlm.nih.gov/pubmed/33806512 http://dx.doi.org/10.3390/mi12030263 |
_version_ | 1783670936503844864 |
---|---|
author | Wang, Rui Wu, Jing He, Xiaodong Zhou, Peng Shen, Zuojun |
author_facet | Wang, Rui Wu, Jing He, Xiaodong Zhou, Peng Shen, Zuojun |
author_sort | Wang, Rui |
collection | PubMed |
description | This paper proposes an automated microfluidic system for molecular diagnostics that integrates the functions of a traditional polymerase chain reaction (PCR) laboratory into a palm-sized microfluidic cartridge (CARD) made of polystyrene. The CARD integrates 4 independent microfluidic sample lanes, which can independently complete a sample test, and each sample lane integrates the 3 functional areas of the sample preparation area, PCR amplification area, and product analysis area. By using chemical cell lysis, magnetic silica bead-based DNA extraction, combined with multi-PCR-reverse dot hybridization with microarray, 24 HPV genotypes can be typing tested in CARD. With a custom-made automated CARD operating platform, the entire process can be automatically carried out, achieving sample-in-answer-out. The custom-made operation platform is developed based on a liquid handling station-type, which can automatically load off-chip reagents without placing reagents in CARD in advance. The platform can control six CARDs to work simultaneously, detect 24 samples at a time. The results show that the limit of detection of the microfluidic system is 200 copies/test, and the positive detection rate of clinical samples by this system is 100%, which is an effective method for detection of HPV. |
format | Online Article Text |
id | pubmed-8000143 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2021 |
publisher | MDPI |
record_format | MEDLINE/PubMed |
spelling | pubmed-80001432021-03-28 A Sample-In-Answer-Out Microfluidic System for the Molecular Diagnostics of 24 HPV Genotypes Using Palm-Sized Cartridge Wang, Rui Wu, Jing He, Xiaodong Zhou, Peng Shen, Zuojun Micromachines (Basel) Article This paper proposes an automated microfluidic system for molecular diagnostics that integrates the functions of a traditional polymerase chain reaction (PCR) laboratory into a palm-sized microfluidic cartridge (CARD) made of polystyrene. The CARD integrates 4 independent microfluidic sample lanes, which can independently complete a sample test, and each sample lane integrates the 3 functional areas of the sample preparation area, PCR amplification area, and product analysis area. By using chemical cell lysis, magnetic silica bead-based DNA extraction, combined with multi-PCR-reverse dot hybridization with microarray, 24 HPV genotypes can be typing tested in CARD. With a custom-made automated CARD operating platform, the entire process can be automatically carried out, achieving sample-in-answer-out. The custom-made operation platform is developed based on a liquid handling station-type, which can automatically load off-chip reagents without placing reagents in CARD in advance. The platform can control six CARDs to work simultaneously, detect 24 samples at a time. The results show that the limit of detection of the microfluidic system is 200 copies/test, and the positive detection rate of clinical samples by this system is 100%, which is an effective method for detection of HPV. MDPI 2021-03-04 /pmc/articles/PMC8000143/ /pubmed/33806512 http://dx.doi.org/10.3390/mi12030263 Text en © 2021 by the authors. https://creativecommons.org/licenses/by/4.0/Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (http://creativecommons.org/licenses/by/4.0/ (https://creativecommons.org/licenses/by/4.0/) ). |
spellingShingle | Article Wang, Rui Wu, Jing He, Xiaodong Zhou, Peng Shen, Zuojun A Sample-In-Answer-Out Microfluidic System for the Molecular Diagnostics of 24 HPV Genotypes Using Palm-Sized Cartridge |
title | A Sample-In-Answer-Out Microfluidic System for the Molecular Diagnostics of 24 HPV Genotypes Using Palm-Sized Cartridge |
title_full | A Sample-In-Answer-Out Microfluidic System for the Molecular Diagnostics of 24 HPV Genotypes Using Palm-Sized Cartridge |
title_fullStr | A Sample-In-Answer-Out Microfluidic System for the Molecular Diagnostics of 24 HPV Genotypes Using Palm-Sized Cartridge |
title_full_unstemmed | A Sample-In-Answer-Out Microfluidic System for the Molecular Diagnostics of 24 HPV Genotypes Using Palm-Sized Cartridge |
title_short | A Sample-In-Answer-Out Microfluidic System for the Molecular Diagnostics of 24 HPV Genotypes Using Palm-Sized Cartridge |
title_sort | sample-in-answer-out microfluidic system for the molecular diagnostics of 24 hpv genotypes using palm-sized cartridge |
topic | Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8000143/ https://www.ncbi.nlm.nih.gov/pubmed/33806512 http://dx.doi.org/10.3390/mi12030263 |
work_keys_str_mv | AT wangrui asampleinansweroutmicrofluidicsystemforthemoleculardiagnosticsof24hpvgenotypesusingpalmsizedcartridge AT wujing asampleinansweroutmicrofluidicsystemforthemoleculardiagnosticsof24hpvgenotypesusingpalmsizedcartridge AT hexiaodong asampleinansweroutmicrofluidicsystemforthemoleculardiagnosticsof24hpvgenotypesusingpalmsizedcartridge AT zhoupeng asampleinansweroutmicrofluidicsystemforthemoleculardiagnosticsof24hpvgenotypesusingpalmsizedcartridge AT shenzuojun asampleinansweroutmicrofluidicsystemforthemoleculardiagnosticsof24hpvgenotypesusingpalmsizedcartridge AT wangrui sampleinansweroutmicrofluidicsystemforthemoleculardiagnosticsof24hpvgenotypesusingpalmsizedcartridge AT wujing sampleinansweroutmicrofluidicsystemforthemoleculardiagnosticsof24hpvgenotypesusingpalmsizedcartridge AT hexiaodong sampleinansweroutmicrofluidicsystemforthemoleculardiagnosticsof24hpvgenotypesusingpalmsizedcartridge AT zhoupeng sampleinansweroutmicrofluidicsystemforthemoleculardiagnosticsof24hpvgenotypesusingpalmsizedcartridge AT shenzuojun sampleinansweroutmicrofluidicsystemforthemoleculardiagnosticsof24hpvgenotypesusingpalmsizedcartridge |