Cargando…

Bone Density Micro-CT Assessment during Embedding of the Innovative Multi-Spiked Connecting Scaffold in Periarticular Bone to Elaborate a Validated Numerical Model for Designing Biomimetic Fixation of Resurfacing Endoprostheses

Our team has been working for some time on designing a new kind of biomimetic fixation of resurfacing endoprostheses, in which the innovative multi-spiked connecting scaffold (MSC-Scaffold) that mimics the natural interface between articular cartilage and periarticular trabecular bone in human joint...

Descripción completa

Detalles Bibliográficos
Autores principales: Uklejewski, Ryszard, Winiecki, Mariusz, Patalas, Adam, Rogala, Piotr
Formato: Online Artículo Texto
Lenguaje:English
Publicado: MDPI 2021
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8000753/
https://www.ncbi.nlm.nih.gov/pubmed/33809176
http://dx.doi.org/10.3390/ma14061384
_version_ 1783671070176313344
author Uklejewski, Ryszard
Winiecki, Mariusz
Patalas, Adam
Rogala, Piotr
author_facet Uklejewski, Ryszard
Winiecki, Mariusz
Patalas, Adam
Rogala, Piotr
author_sort Uklejewski, Ryszard
collection PubMed
description Our team has been working for some time on designing a new kind of biomimetic fixation of resurfacing endoprostheses, in which the innovative multi-spiked connecting scaffold (MSC-Scaffold) that mimics the natural interface between articular cartilage and periarticular trabecular bone in human joints is the crucial element. This work aimed to develop a numerical model enabling the design of the considered joint replacement implant that would reflect the mechanics of interacting biomaterials. Thus, quantitative micro-CT analysis of density distribution in bone material during the embedding of MSC-Scaffold in periarticular bone was applied. The performed numerical studies and corresponding mechanical tests revealed, under the embedded MSC-Scaffold, the bone material densification affecting its mechanical properties. On the basis of these findings, the built numerical model was modified by applying a simulated insert of densified bone material. This modification led to a strong correlation between the re-simulation and experimental results (FVU = 0.02). The biomimetism of the MSC-Scaffold prototype that provided physiological load transfer from implant to bone was confirmed based on the Huber–von Mises–Hencky (HMH) stress maps obtained with the validated finite element (FE) model of the problem. The micro-CT bone density assessment performed during the embedding of the MSC-Scaffold prototype in periarticular bone provides insight into the mechanical behaviour of the investigated implant-bone system and validates the numerical model that can be used for the design of material and geometric features of a new kind of resurfacing endoprostheses fixation.
format Online
Article
Text
id pubmed-8000753
institution National Center for Biotechnology Information
language English
publishDate 2021
publisher MDPI
record_format MEDLINE/PubMed
spelling pubmed-80007532021-03-28 Bone Density Micro-CT Assessment during Embedding of the Innovative Multi-Spiked Connecting Scaffold in Periarticular Bone to Elaborate a Validated Numerical Model for Designing Biomimetic Fixation of Resurfacing Endoprostheses Uklejewski, Ryszard Winiecki, Mariusz Patalas, Adam Rogala, Piotr Materials (Basel) Article Our team has been working for some time on designing a new kind of biomimetic fixation of resurfacing endoprostheses, in which the innovative multi-spiked connecting scaffold (MSC-Scaffold) that mimics the natural interface between articular cartilage and periarticular trabecular bone in human joints is the crucial element. This work aimed to develop a numerical model enabling the design of the considered joint replacement implant that would reflect the mechanics of interacting biomaterials. Thus, quantitative micro-CT analysis of density distribution in bone material during the embedding of MSC-Scaffold in periarticular bone was applied. The performed numerical studies and corresponding mechanical tests revealed, under the embedded MSC-Scaffold, the bone material densification affecting its mechanical properties. On the basis of these findings, the built numerical model was modified by applying a simulated insert of densified bone material. This modification led to a strong correlation between the re-simulation and experimental results (FVU = 0.02). The biomimetism of the MSC-Scaffold prototype that provided physiological load transfer from implant to bone was confirmed based on the Huber–von Mises–Hencky (HMH) stress maps obtained with the validated finite element (FE) model of the problem. The micro-CT bone density assessment performed during the embedding of the MSC-Scaffold prototype in periarticular bone provides insight into the mechanical behaviour of the investigated implant-bone system and validates the numerical model that can be used for the design of material and geometric features of a new kind of resurfacing endoprostheses fixation. MDPI 2021-03-12 /pmc/articles/PMC8000753/ /pubmed/33809176 http://dx.doi.org/10.3390/ma14061384 Text en © 2021 by the authors. Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (http://creativecommons.org/licenses/by/4.0/).
spellingShingle Article
Uklejewski, Ryszard
Winiecki, Mariusz
Patalas, Adam
Rogala, Piotr
Bone Density Micro-CT Assessment during Embedding of the Innovative Multi-Spiked Connecting Scaffold in Periarticular Bone to Elaborate a Validated Numerical Model for Designing Biomimetic Fixation of Resurfacing Endoprostheses
title Bone Density Micro-CT Assessment during Embedding of the Innovative Multi-Spiked Connecting Scaffold in Periarticular Bone to Elaborate a Validated Numerical Model for Designing Biomimetic Fixation of Resurfacing Endoprostheses
title_full Bone Density Micro-CT Assessment during Embedding of the Innovative Multi-Spiked Connecting Scaffold in Periarticular Bone to Elaborate a Validated Numerical Model for Designing Biomimetic Fixation of Resurfacing Endoprostheses
title_fullStr Bone Density Micro-CT Assessment during Embedding of the Innovative Multi-Spiked Connecting Scaffold in Periarticular Bone to Elaborate a Validated Numerical Model for Designing Biomimetic Fixation of Resurfacing Endoprostheses
title_full_unstemmed Bone Density Micro-CT Assessment during Embedding of the Innovative Multi-Spiked Connecting Scaffold in Periarticular Bone to Elaborate a Validated Numerical Model for Designing Biomimetic Fixation of Resurfacing Endoprostheses
title_short Bone Density Micro-CT Assessment during Embedding of the Innovative Multi-Spiked Connecting Scaffold in Periarticular Bone to Elaborate a Validated Numerical Model for Designing Biomimetic Fixation of Resurfacing Endoprostheses
title_sort bone density micro-ct assessment during embedding of the innovative multi-spiked connecting scaffold in periarticular bone to elaborate a validated numerical model for designing biomimetic fixation of resurfacing endoprostheses
topic Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8000753/
https://www.ncbi.nlm.nih.gov/pubmed/33809176
http://dx.doi.org/10.3390/ma14061384
work_keys_str_mv AT uklejewskiryszard bonedensitymicroctassessmentduringembeddingoftheinnovativemultispikedconnectingscaffoldinperiarticularbonetoelaborateavalidatednumericalmodelfordesigningbiomimeticfixationofresurfacingendoprostheses
AT winieckimariusz bonedensitymicroctassessmentduringembeddingoftheinnovativemultispikedconnectingscaffoldinperiarticularbonetoelaborateavalidatednumericalmodelfordesigningbiomimeticfixationofresurfacingendoprostheses
AT patalasadam bonedensitymicroctassessmentduringembeddingoftheinnovativemultispikedconnectingscaffoldinperiarticularbonetoelaborateavalidatednumericalmodelfordesigningbiomimeticfixationofresurfacingendoprostheses
AT rogalapiotr bonedensitymicroctassessmentduringembeddingoftheinnovativemultispikedconnectingscaffoldinperiarticularbonetoelaborateavalidatednumericalmodelfordesigningbiomimeticfixationofresurfacingendoprostheses