Cargando…

Immobilization-Free Electrochemical Sensor Coupled with a Graphene-Oxide-Based Aptasensor for Glycated Albumin Detection

An immobilization-free electrochemical sensor coupled with a graphene oxide (GO)-based aptasensor was developed for glycated human serum albumin (GHSA) detection. The concentration of GHSA was monitored by measuring the electrochemical response of free GO and aptamer-bound GO in the presence of glyc...

Descripción completa

Detalles Bibliográficos
Autores principales: Waiwinya, Wassa, Putnin, Thitirat, Pimalai, Dechnarong, Chawjiraphan, Wireeya, Sathirapongsasuti, Nuankanya, Japrung, Deanpen
Formato: Online Artículo Texto
Lenguaje:English
Publicado: MDPI 2021
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8002523/
https://www.ncbi.nlm.nih.gov/pubmed/33802824
http://dx.doi.org/10.3390/bios11030085
_version_ 1783671483473592320
author Waiwinya, Wassa
Putnin, Thitirat
Pimalai, Dechnarong
Chawjiraphan, Wireeya
Sathirapongsasuti, Nuankanya
Japrung, Deanpen
author_facet Waiwinya, Wassa
Putnin, Thitirat
Pimalai, Dechnarong
Chawjiraphan, Wireeya
Sathirapongsasuti, Nuankanya
Japrung, Deanpen
author_sort Waiwinya, Wassa
collection PubMed
description An immobilization-free electrochemical sensor coupled with a graphene oxide (GO)-based aptasensor was developed for glycated human serum albumin (GHSA) detection. The concentration of GHSA was monitored by measuring the electrochemical response of free GO and aptamer-bound GO in the presence of glycated albumin; their currents served as the analytical signals. The electrochemical aptasensor exhibited good performance with a base-10 logarithmic scale. The calibration curve was achieved in the range of 0.01–50 µg/mL. The limit of detection (LOD) was 8.70 ng/mL. The developed method was considered a one-drop measurement process because a fabrication step and the probe-immobilization process were not required. This simple sensor offers a cost-effective, rapid, and sensitive detection method, and could be an alternative approach for determination of GHSA levels.
format Online
Article
Text
id pubmed-8002523
institution National Center for Biotechnology Information
language English
publishDate 2021
publisher MDPI
record_format MEDLINE/PubMed
spelling pubmed-80025232021-03-28 Immobilization-Free Electrochemical Sensor Coupled with a Graphene-Oxide-Based Aptasensor for Glycated Albumin Detection Waiwinya, Wassa Putnin, Thitirat Pimalai, Dechnarong Chawjiraphan, Wireeya Sathirapongsasuti, Nuankanya Japrung, Deanpen Biosensors (Basel) Article An immobilization-free electrochemical sensor coupled with a graphene oxide (GO)-based aptasensor was developed for glycated human serum albumin (GHSA) detection. The concentration of GHSA was monitored by measuring the electrochemical response of free GO and aptamer-bound GO in the presence of glycated albumin; their currents served as the analytical signals. The electrochemical aptasensor exhibited good performance with a base-10 logarithmic scale. The calibration curve was achieved in the range of 0.01–50 µg/mL. The limit of detection (LOD) was 8.70 ng/mL. The developed method was considered a one-drop measurement process because a fabrication step and the probe-immobilization process were not required. This simple sensor offers a cost-effective, rapid, and sensitive detection method, and could be an alternative approach for determination of GHSA levels. MDPI 2021-03-17 /pmc/articles/PMC8002523/ /pubmed/33802824 http://dx.doi.org/10.3390/bios11030085 Text en © 2021 by the authors. https://creativecommons.org/licenses/by/4.0/Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (http://creativecommons.org/licenses/by/4.0/ (https://creativecommons.org/licenses/by/4.0/) ).
spellingShingle Article
Waiwinya, Wassa
Putnin, Thitirat
Pimalai, Dechnarong
Chawjiraphan, Wireeya
Sathirapongsasuti, Nuankanya
Japrung, Deanpen
Immobilization-Free Electrochemical Sensor Coupled with a Graphene-Oxide-Based Aptasensor for Glycated Albumin Detection
title Immobilization-Free Electrochemical Sensor Coupled with a Graphene-Oxide-Based Aptasensor for Glycated Albumin Detection
title_full Immobilization-Free Electrochemical Sensor Coupled with a Graphene-Oxide-Based Aptasensor for Glycated Albumin Detection
title_fullStr Immobilization-Free Electrochemical Sensor Coupled with a Graphene-Oxide-Based Aptasensor for Glycated Albumin Detection
title_full_unstemmed Immobilization-Free Electrochemical Sensor Coupled with a Graphene-Oxide-Based Aptasensor for Glycated Albumin Detection
title_short Immobilization-Free Electrochemical Sensor Coupled with a Graphene-Oxide-Based Aptasensor for Glycated Albumin Detection
title_sort immobilization-free electrochemical sensor coupled with a graphene-oxide-based aptasensor for glycated albumin detection
topic Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8002523/
https://www.ncbi.nlm.nih.gov/pubmed/33802824
http://dx.doi.org/10.3390/bios11030085
work_keys_str_mv AT waiwinyawassa immobilizationfreeelectrochemicalsensorcoupledwithagrapheneoxidebasedaptasensorforglycatedalbumindetection
AT putninthitirat immobilizationfreeelectrochemicalsensorcoupledwithagrapheneoxidebasedaptasensorforglycatedalbumindetection
AT pimalaidechnarong immobilizationfreeelectrochemicalsensorcoupledwithagrapheneoxidebasedaptasensorforglycatedalbumindetection
AT chawjiraphanwireeya immobilizationfreeelectrochemicalsensorcoupledwithagrapheneoxidebasedaptasensorforglycatedalbumindetection
AT sathirapongsasutinuankanya immobilizationfreeelectrochemicalsensorcoupledwithagrapheneoxidebasedaptasensorforglycatedalbumindetection
AT japrungdeanpen immobilizationfreeelectrochemicalsensorcoupledwithagrapheneoxidebasedaptasensorforglycatedalbumindetection