Characterizing the Performance of a Compact BTEX GC-PID for Near-Real Time Analysis and Field Deployment

In this study, we test the performance of a compact gas chromatograph with photoionization detector (GC-PID) and optimize the configuration to detect ambient (sub-ppb) levels of benzene, toluene, ethylbenzene, and xylene isomers (BTEX). The GC-PID system was designed to serve as a relatively inexpen...

Descripción completa

Detalles Bibliográficos
Autores principales: Frausto-Vicencio, Isis, Moreno, Alondra, Goldsmith, Hugh, Hsu, Ying-Kuang, Hopkins, Francesca M.
Formato: Online Artículo Texto
Lenguaje:English
Publicado: MDPI 2021
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8002566/
https://www.ncbi.nlm.nih.gov/pubmed/33802681
http://dx.doi.org/10.3390/s21062095
_version_ 1783671493543067648
author Frausto-Vicencio, Isis
Moreno, Alondra
Goldsmith, Hugh
Hsu, Ying-Kuang
Hopkins, Francesca M.
author_facet Frausto-Vicencio, Isis
Moreno, Alondra
Goldsmith, Hugh
Hsu, Ying-Kuang
Hopkins, Francesca M.
author_sort Frausto-Vicencio, Isis
collection PubMed
description In this study, we test the performance of a compact gas chromatograph with photoionization detector (GC-PID) and optimize the configuration to detect ambient (sub-ppb) levels of benzene, toluene, ethylbenzene, and xylene isomers (BTEX). The GC-PID system was designed to serve as a relatively inexpensive (~10 k USD) and field-deployable air toxic screening tool alternative to conventional benchtop GCs. The instrument uses ambient air as a carrier gas and consists of a Tenax-GR sorbent-based preconcentrator, a gas sample valve, two capillary columns, and a photoionization detector (PID) with a small footprint and low power requirement. The performance of the GC-PID has been evaluated in terms of system linearity and sensitivity in field conditions. The BTEX-GC system demonstrated the capacity to detect BTEX at levels as high as 500 ppb with a linear calibration range of 0–100 ppb. A detection limit lower than 1 ppb was found for all BTEX compounds with a sampling volume of 1 L. No significant drift in the instrument was observed. A time-varying calibration technique was established that requires minimal equipment for field operations and optimizes the sampling procedure for field measurements. With an analysis time of less than 15 min, the compact GC-PID is ideal for field deployment of background and polluted atmospheres for near-real time measurements of BTEX. The results highlight the application of the compact and easily deployable GC-PID for community monitoring and screening of air toxics.
format Online
Article
Text
id pubmed-8002566
institution National Center for Biotechnology Information
language English
publishDate 2021
publisher MDPI
record_format MEDLINE/PubMed
spelling pubmed-80025662021-03-28 Characterizing the Performance of a Compact BTEX GC-PID for Near-Real Time Analysis and Field Deployment Frausto-Vicencio, Isis Moreno, Alondra Goldsmith, Hugh Hsu, Ying-Kuang Hopkins, Francesca M. Sensors (Basel) Article In this study, we test the performance of a compact gas chromatograph with photoionization detector (GC-PID) and optimize the configuration to detect ambient (sub-ppb) levels of benzene, toluene, ethylbenzene, and xylene isomers (BTEX). The GC-PID system was designed to serve as a relatively inexpensive (~10 k USD) and field-deployable air toxic screening tool alternative to conventional benchtop GCs. The instrument uses ambient air as a carrier gas and consists of a Tenax-GR sorbent-based preconcentrator, a gas sample valve, two capillary columns, and a photoionization detector (PID) with a small footprint and low power requirement. The performance of the GC-PID has been evaluated in terms of system linearity and sensitivity in field conditions. The BTEX-GC system demonstrated the capacity to detect BTEX at levels as high as 500 ppb with a linear calibration range of 0–100 ppb. A detection limit lower than 1 ppb was found for all BTEX compounds with a sampling volume of 1 L. No significant drift in the instrument was observed. A time-varying calibration technique was established that requires minimal equipment for field operations and optimizes the sampling procedure for field measurements. With an analysis time of less than 15 min, the compact GC-PID is ideal for field deployment of background and polluted atmospheres for near-real time measurements of BTEX. The results highlight the application of the compact and easily deployable GC-PID for community monitoring and screening of air toxics. MDPI 2021-03-17 /pmc/articles/PMC8002566/ /pubmed/33802681 http://dx.doi.org/10.3390/s21062095 Text en © 2021 by the authors. Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (http://creativecommons.org/licenses/by/4.0/).
spellingShingle Article
Frausto-Vicencio, Isis
Moreno, Alondra
Goldsmith, Hugh
Hsu, Ying-Kuang
Hopkins, Francesca M.
Characterizing the Performance of a Compact BTEX GC-PID for Near-Real Time Analysis and Field Deployment
title Characterizing the Performance of a Compact BTEX GC-PID for Near-Real Time Analysis and Field Deployment
title_full Characterizing the Performance of a Compact BTEX GC-PID for Near-Real Time Analysis and Field Deployment
title_fullStr Characterizing the Performance of a Compact BTEX GC-PID for Near-Real Time Analysis and Field Deployment
title_full_unstemmed Characterizing the Performance of a Compact BTEX GC-PID for Near-Real Time Analysis and Field Deployment
title_short Characterizing the Performance of a Compact BTEX GC-PID for Near-Real Time Analysis and Field Deployment
title_sort characterizing the performance of a compact btex gc-pid for near-real time analysis and field deployment
topic Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8002566/
https://www.ncbi.nlm.nih.gov/pubmed/33802681
http://dx.doi.org/10.3390/s21062095
work_keys_str_mv AT fraustovicencioisis characterizingtheperformanceofacompactbtexgcpidfornearrealtimeanalysisandfielddeployment
AT morenoalondra characterizingtheperformanceofacompactbtexgcpidfornearrealtimeanalysisandfielddeployment
AT goldsmithhugh characterizingtheperformanceofacompactbtexgcpidfornearrealtimeanalysisandfielddeployment
AT hsuyingkuang characterizingtheperformanceofacompactbtexgcpidfornearrealtimeanalysisandfielddeployment
AT hopkinsfrancescam characterizingtheperformanceofacompactbtexgcpidfornearrealtimeanalysisandfielddeployment