Cargando…
Corona Charging of Isotactic-Polypropylene Composites
A new approach to obtaining piezoelectric polymeric films based on the isotactic-polypropylene (i-PP) using corona discharge with the energy of 45 W·min/m(2) was presented. Detailed analyses with Atomic Force Microscopy (AFM) led to the conclusion that the surface quality was the important factor in...
Autores principales: | , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
MDPI
2021
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8003178/ https://www.ncbi.nlm.nih.gov/pubmed/33803870 http://dx.doi.org/10.3390/polym13060942 |
_version_ | 1783671628799934464 |
---|---|
author | Kowalonek, Jolanta Kaczmarek, Halina Królikowski, Bogusław Klimiec, Ewa Chylińska, Marta |
author_facet | Kowalonek, Jolanta Kaczmarek, Halina Królikowski, Bogusław Klimiec, Ewa Chylińska, Marta |
author_sort | Kowalonek, Jolanta |
collection | PubMed |
description | A new approach to obtaining piezoelectric polymeric films based on the isotactic-polypropylene (i-PP) using corona discharge with the energy of 45 W·min/m(2) was presented. Detailed analyses with Atomic Force Microscopy (AFM) led to the conclusion that the surface quality was the important factor influencing the possibility of charging the i-PP composites, which was necessary to induce the permanent piezoelectric effect. It has been found that the high surface smoothness of the polymer films contributed to improved piezoelectric properties without the need for an additional polymer modification such as orientation, foaming or doping with fillers. The values of the piezoelectric constant, d(33), of the studied samples were compared to these values for the analogous systems polarized with a constant electric field of 100 V/μm. The milder conditions of the film polarization during the corona discharge process are sufficient to achieve the electrets in i-PP films. The simple and cheap method proposed can be profitable in obtaining flexible electrets in the form of thin films for the production of personal biomedical sensors. |
format | Online Article Text |
id | pubmed-8003178 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2021 |
publisher | MDPI |
record_format | MEDLINE/PubMed |
spelling | pubmed-80031782021-03-28 Corona Charging of Isotactic-Polypropylene Composites Kowalonek, Jolanta Kaczmarek, Halina Królikowski, Bogusław Klimiec, Ewa Chylińska, Marta Polymers (Basel) Article A new approach to obtaining piezoelectric polymeric films based on the isotactic-polypropylene (i-PP) using corona discharge with the energy of 45 W·min/m(2) was presented. Detailed analyses with Atomic Force Microscopy (AFM) led to the conclusion that the surface quality was the important factor influencing the possibility of charging the i-PP composites, which was necessary to induce the permanent piezoelectric effect. It has been found that the high surface smoothness of the polymer films contributed to improved piezoelectric properties without the need for an additional polymer modification such as orientation, foaming or doping with fillers. The values of the piezoelectric constant, d(33), of the studied samples were compared to these values for the analogous systems polarized with a constant electric field of 100 V/μm. The milder conditions of the film polarization during the corona discharge process are sufficient to achieve the electrets in i-PP films. The simple and cheap method proposed can be profitable in obtaining flexible electrets in the form of thin films for the production of personal biomedical sensors. MDPI 2021-03-18 /pmc/articles/PMC8003178/ /pubmed/33803870 http://dx.doi.org/10.3390/polym13060942 Text en © 2021 by the authors. Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (http://creativecommons.org/licenses/by/4.0/). |
spellingShingle | Article Kowalonek, Jolanta Kaczmarek, Halina Królikowski, Bogusław Klimiec, Ewa Chylińska, Marta Corona Charging of Isotactic-Polypropylene Composites |
title | Corona Charging of Isotactic-Polypropylene Composites |
title_full | Corona Charging of Isotactic-Polypropylene Composites |
title_fullStr | Corona Charging of Isotactic-Polypropylene Composites |
title_full_unstemmed | Corona Charging of Isotactic-Polypropylene Composites |
title_short | Corona Charging of Isotactic-Polypropylene Composites |
title_sort | corona charging of isotactic-polypropylene composites |
topic | Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8003178/ https://www.ncbi.nlm.nih.gov/pubmed/33803870 http://dx.doi.org/10.3390/polym13060942 |
work_keys_str_mv | AT kowalonekjolanta coronachargingofisotacticpolypropylenecomposites AT kaczmarekhalina coronachargingofisotacticpolypropylenecomposites AT krolikowskibogusław coronachargingofisotacticpolypropylenecomposites AT klimiecewa coronachargingofisotacticpolypropylenecomposites AT chylinskamarta coronachargingofisotacticpolypropylenecomposites |