Cargando…

Evaluation of the Metrological Performance of a Handheld 3D Laser Scanner Using a Pseudo-3D Ball-Lattice Artifact

This paper proposes the use of a pseudo-3D ball-lattice artifact to characterize a handheld laser scanner from a metrological standpoint. The artifact allows the computation of local and global errors in measurement by using the reference-frame-independent parameters of size, form, and distance with...

Descripción completa

Detalles Bibliográficos
Autores principales: Bonin, Rémi, Khameneifar, Farbod, Mayer, J.R.R.
Formato: Online Artículo Texto
Lenguaje:English
Publicado: MDPI 2021
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8003233/
https://www.ncbi.nlm.nih.gov/pubmed/33803746
http://dx.doi.org/10.3390/s21062137
_version_ 1783671641530695680
author Bonin, Rémi
Khameneifar, Farbod
Mayer, J.R.R.
author_facet Bonin, Rémi
Khameneifar, Farbod
Mayer, J.R.R.
author_sort Bonin, Rémi
collection PubMed
description This paper proposes the use of a pseudo-3D ball-lattice artifact to characterize a handheld laser scanner from a metrological standpoint. The artifact allows the computation of local and global errors in measurement by using the reference-frame-independent parameters of size, form, and distance within the measuring volume of the scanner, and in a single point cloud, without the need for registration. A set of tests was performed using the whole measuring volume, and three acquisition parameters, namely the orientation of the sweeps during the scans, the exposure time, and the distance to the scanner were analyzed for their effects on the accuracy of the scan data. A composite error including the errors in measuring size, form, and distance was used as a single figure of merit to characterize the performance of the scanner in relation to the data-acquisition parameters. The orientation of sweeps did not have a considerable effect on the errors. The accuracy of the scan data was strongly affected by exposure time and its interaction with the distance at which the artifact was scanned. The errors followed a quadratic trend with respect to the distance of the artifact to the scanner. The tested scanner performed best at its manufacturer’s recommended stand-off distance.
format Online
Article
Text
id pubmed-8003233
institution National Center for Biotechnology Information
language English
publishDate 2021
publisher MDPI
record_format MEDLINE/PubMed
spelling pubmed-80032332021-03-28 Evaluation of the Metrological Performance of a Handheld 3D Laser Scanner Using a Pseudo-3D Ball-Lattice Artifact Bonin, Rémi Khameneifar, Farbod Mayer, J.R.R. Sensors (Basel) Article This paper proposes the use of a pseudo-3D ball-lattice artifact to characterize a handheld laser scanner from a metrological standpoint. The artifact allows the computation of local and global errors in measurement by using the reference-frame-independent parameters of size, form, and distance within the measuring volume of the scanner, and in a single point cloud, without the need for registration. A set of tests was performed using the whole measuring volume, and three acquisition parameters, namely the orientation of the sweeps during the scans, the exposure time, and the distance to the scanner were analyzed for their effects on the accuracy of the scan data. A composite error including the errors in measuring size, form, and distance was used as a single figure of merit to characterize the performance of the scanner in relation to the data-acquisition parameters. The orientation of sweeps did not have a considerable effect on the errors. The accuracy of the scan data was strongly affected by exposure time and its interaction with the distance at which the artifact was scanned. The errors followed a quadratic trend with respect to the distance of the artifact to the scanner. The tested scanner performed best at its manufacturer’s recommended stand-off distance. MDPI 2021-03-18 /pmc/articles/PMC8003233/ /pubmed/33803746 http://dx.doi.org/10.3390/s21062137 Text en © 2021 by the authors. Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (http://creativecommons.org/licenses/by/4.0/).
spellingShingle Article
Bonin, Rémi
Khameneifar, Farbod
Mayer, J.R.R.
Evaluation of the Metrological Performance of a Handheld 3D Laser Scanner Using a Pseudo-3D Ball-Lattice Artifact
title Evaluation of the Metrological Performance of a Handheld 3D Laser Scanner Using a Pseudo-3D Ball-Lattice Artifact
title_full Evaluation of the Metrological Performance of a Handheld 3D Laser Scanner Using a Pseudo-3D Ball-Lattice Artifact
title_fullStr Evaluation of the Metrological Performance of a Handheld 3D Laser Scanner Using a Pseudo-3D Ball-Lattice Artifact
title_full_unstemmed Evaluation of the Metrological Performance of a Handheld 3D Laser Scanner Using a Pseudo-3D Ball-Lattice Artifact
title_short Evaluation of the Metrological Performance of a Handheld 3D Laser Scanner Using a Pseudo-3D Ball-Lattice Artifact
title_sort evaluation of the metrological performance of a handheld 3d laser scanner using a pseudo-3d ball-lattice artifact
topic Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8003233/
https://www.ncbi.nlm.nih.gov/pubmed/33803746
http://dx.doi.org/10.3390/s21062137
work_keys_str_mv AT boninremi evaluationofthemetrologicalperformanceofahandheld3dlaserscannerusingapseudo3dballlatticeartifact
AT khameneifarfarbod evaluationofthemetrologicalperformanceofahandheld3dlaserscannerusingapseudo3dballlatticeartifact
AT mayerjrr evaluationofthemetrologicalperformanceofahandheld3dlaserscannerusingapseudo3dballlatticeartifact