Cargando…
Label-Free and Highly-Sensitive Detection of Ochratoxin A Using One-Pot Synthesized Reduced Graphene Oxide/Gold Nanoparticles-Based Impedimetric Aptasensor
Ochratoxin A (OTA) primarily obtained by the genera aspergillus and penicillium, is one of the toxic substances for different organs and systems of the human body such as the kidney, liver, neurons and the immune system. Moreover, it is considered to cause tumors and fetal malformation even at a ver...
Autores principales: | , , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
MDPI
2021
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8003581/ https://www.ncbi.nlm.nih.gov/pubmed/33808613 http://dx.doi.org/10.3390/bios11030087 |
_version_ | 1783671723525144576 |
---|---|
author | Alhamoud, Yasmin Li, Yingying Zhou, Haibo Al-Wazer, Ragwa Gong, Yiying Zhi, Shuai Yang, Danting |
author_facet | Alhamoud, Yasmin Li, Yingying Zhou, Haibo Al-Wazer, Ragwa Gong, Yiying Zhi, Shuai Yang, Danting |
author_sort | Alhamoud, Yasmin |
collection | PubMed |
description | Ochratoxin A (OTA) primarily obtained by the genera aspergillus and penicillium, is one of the toxic substances for different organs and systems of the human body such as the kidney, liver, neurons and the immune system. Moreover, it is considered to cause tumors and fetal malformation even at a very low concentration. Fast and sensitive assay for detection of OTA at ultralow levels in foods and agricultural products has been an increasing demand. In this study, a new label-free electrochemical biosensor based on three-dimensional reduced graphene oxide/gold nanoparticles/aptamer for OTA detection was constructed. The 3D-rGO/Au NPs nanocomposites were firstly synthesized using a one-pot hydrothermal process under optimized experimental conditions. The 3D-rGO/Au NPs with considerable particular surface area and outstanding electrical conductivity was then coated on a glass carbon electrode to provide tremendous binding sites for -SH modified aptamer via the distinctive Au–S linkage. The presence of OTA was specifically captured by aptamer and resulted in electrochemical impedance spectroscopy (EIS) signal response accordingly. The constructed impedimetric aptasensor obtained a broad linear response from 1 pg/mL to 10 ng/mL with an LOD of 0.34 pg/mL toward OTA detection, highlighting the excellent sensitivity. Satisfactory reproducibility was also achieved with the relative standard deviation (RSD) of 1.393%. Moreover, the proposed aptasensor obtained a good recovery of OTA detection in red wine samples within the range of 93.14 to 112.75% along with a low LOD of 0.023 ng/mL, indicating its applicability for OTA detection in real samples along with economical, specific, susceptible, fast, easy, and transportable merits. |
format | Online Article Text |
id | pubmed-8003581 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2021 |
publisher | MDPI |
record_format | MEDLINE/PubMed |
spelling | pubmed-80035812021-03-28 Label-Free and Highly-Sensitive Detection of Ochratoxin A Using One-Pot Synthesized Reduced Graphene Oxide/Gold Nanoparticles-Based Impedimetric Aptasensor Alhamoud, Yasmin Li, Yingying Zhou, Haibo Al-Wazer, Ragwa Gong, Yiying Zhi, Shuai Yang, Danting Biosensors (Basel) Article Ochratoxin A (OTA) primarily obtained by the genera aspergillus and penicillium, is one of the toxic substances for different organs and systems of the human body such as the kidney, liver, neurons and the immune system. Moreover, it is considered to cause tumors and fetal malformation even at a very low concentration. Fast and sensitive assay for detection of OTA at ultralow levels in foods and agricultural products has been an increasing demand. In this study, a new label-free electrochemical biosensor based on three-dimensional reduced graphene oxide/gold nanoparticles/aptamer for OTA detection was constructed. The 3D-rGO/Au NPs nanocomposites were firstly synthesized using a one-pot hydrothermal process under optimized experimental conditions. The 3D-rGO/Au NPs with considerable particular surface area and outstanding electrical conductivity was then coated on a glass carbon electrode to provide tremendous binding sites for -SH modified aptamer via the distinctive Au–S linkage. The presence of OTA was specifically captured by aptamer and resulted in electrochemical impedance spectroscopy (EIS) signal response accordingly. The constructed impedimetric aptasensor obtained a broad linear response from 1 pg/mL to 10 ng/mL with an LOD of 0.34 pg/mL toward OTA detection, highlighting the excellent sensitivity. Satisfactory reproducibility was also achieved with the relative standard deviation (RSD) of 1.393%. Moreover, the proposed aptasensor obtained a good recovery of OTA detection in red wine samples within the range of 93.14 to 112.75% along with a low LOD of 0.023 ng/mL, indicating its applicability for OTA detection in real samples along with economical, specific, susceptible, fast, easy, and transportable merits. MDPI 2021-03-19 /pmc/articles/PMC8003581/ /pubmed/33808613 http://dx.doi.org/10.3390/bios11030087 Text en © 2021 by the authors. https://creativecommons.org/licenses/by/4.0/Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (http://creativecommons.org/licenses/by/4.0/ (https://creativecommons.org/licenses/by/4.0/) ). |
spellingShingle | Article Alhamoud, Yasmin Li, Yingying Zhou, Haibo Al-Wazer, Ragwa Gong, Yiying Zhi, Shuai Yang, Danting Label-Free and Highly-Sensitive Detection of Ochratoxin A Using One-Pot Synthesized Reduced Graphene Oxide/Gold Nanoparticles-Based Impedimetric Aptasensor |
title | Label-Free and Highly-Sensitive Detection of Ochratoxin A Using One-Pot Synthesized Reduced Graphene Oxide/Gold Nanoparticles-Based Impedimetric Aptasensor |
title_full | Label-Free and Highly-Sensitive Detection of Ochratoxin A Using One-Pot Synthesized Reduced Graphene Oxide/Gold Nanoparticles-Based Impedimetric Aptasensor |
title_fullStr | Label-Free and Highly-Sensitive Detection of Ochratoxin A Using One-Pot Synthesized Reduced Graphene Oxide/Gold Nanoparticles-Based Impedimetric Aptasensor |
title_full_unstemmed | Label-Free and Highly-Sensitive Detection of Ochratoxin A Using One-Pot Synthesized Reduced Graphene Oxide/Gold Nanoparticles-Based Impedimetric Aptasensor |
title_short | Label-Free and Highly-Sensitive Detection of Ochratoxin A Using One-Pot Synthesized Reduced Graphene Oxide/Gold Nanoparticles-Based Impedimetric Aptasensor |
title_sort | label-free and highly-sensitive detection of ochratoxin a using one-pot synthesized reduced graphene oxide/gold nanoparticles-based impedimetric aptasensor |
topic | Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8003581/ https://www.ncbi.nlm.nih.gov/pubmed/33808613 http://dx.doi.org/10.3390/bios11030087 |
work_keys_str_mv | AT alhamoudyasmin labelfreeandhighlysensitivedetectionofochratoxinausingonepotsynthesizedreducedgrapheneoxidegoldnanoparticlesbasedimpedimetricaptasensor AT liyingying labelfreeandhighlysensitivedetectionofochratoxinausingonepotsynthesizedreducedgrapheneoxidegoldnanoparticlesbasedimpedimetricaptasensor AT zhouhaibo labelfreeandhighlysensitivedetectionofochratoxinausingonepotsynthesizedreducedgrapheneoxidegoldnanoparticlesbasedimpedimetricaptasensor AT alwazerragwa labelfreeandhighlysensitivedetectionofochratoxinausingonepotsynthesizedreducedgrapheneoxidegoldnanoparticlesbasedimpedimetricaptasensor AT gongyiying labelfreeandhighlysensitivedetectionofochratoxinausingonepotsynthesizedreducedgrapheneoxidegoldnanoparticlesbasedimpedimetricaptasensor AT zhishuai labelfreeandhighlysensitivedetectionofochratoxinausingonepotsynthesizedreducedgrapheneoxidegoldnanoparticlesbasedimpedimetricaptasensor AT yangdanting labelfreeandhighlysensitivedetectionofochratoxinausingonepotsynthesizedreducedgrapheneoxidegoldnanoparticlesbasedimpedimetricaptasensor |