Cargando…
The comparison of the effect of innovative designed storing-restoring hybrid passive AFO versus posterior leaf spring AFO on ankle joint kinematic in drop foot patients: A case series using a single subject design
Background: Drop foot syndrome is a disorder characterized by foot slapping after the initial contact and foot-dragging during the swing phase. Passive and hybrid passive ankle foot orthoses (AFOs) are often prescribed in these patients; however, the effects of these AFO designs on kinematic paramet...
Autores principales: | , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Iran University of Medical Sciences
2020
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8004578/ https://www.ncbi.nlm.nih.gov/pubmed/33816372 http://dx.doi.org/10.47176/mjiri.34.173 |
_version_ | 1783671934314086400 |
---|---|
author | Pourhoseingholi, Ensieh Kamali, Mohammad Saeedi, Hassan Jalali, Maryam |
author_facet | Pourhoseingholi, Ensieh Kamali, Mohammad Saeedi, Hassan Jalali, Maryam |
author_sort | Pourhoseingholi, Ensieh |
collection | PubMed |
description | Background: Drop foot syndrome is a disorder characterized by foot slapping after the initial contact and foot-dragging during the swing phase. Passive and hybrid passive ankle foot orthoses (AFOs) are often prescribed in these patients; however, the effects of these AFO designs on kinematic parameters during gait are unclear. The aim of this study was to compare the effect of innovative designed storing-restoring hybrid passive AFOs versus posterior leaf spring AFO on ankle joint kinematics in drop foot patients. Methods: The present study was a case series where a single case and 3 cases with drop foot syndrome were recruited. This study was designed in 2 phases: the baseline phase with their PLS AFOs and an intervention phase in which innovative designed AFO were assessed. Each phase included 5 measurement sessions which were performed in 5 consecutive weeks. The celeration line method was used to detect the significant differences between the phases. Results: The results of this study showed a significant increase in the kinematic angles parameters at the initial contact, the loading response, the mid stance, terminal stance, pre swing, initial swing, mid swing, and terminal swing with the innovative designed AFO than with PLS AFO (p<0.05). Conclusion: The results of the present study suggested that use of the innovative designed AFO may have a positive effect on ankle joint kinematics parameters in people with drop foot. |
format | Online Article Text |
id | pubmed-8004578 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2020 |
publisher | Iran University of Medical Sciences |
record_format | MEDLINE/PubMed |
spelling | pubmed-80045782021-04-01 The comparison of the effect of innovative designed storing-restoring hybrid passive AFO versus posterior leaf spring AFO on ankle joint kinematic in drop foot patients: A case series using a single subject design Pourhoseingholi, Ensieh Kamali, Mohammad Saeedi, Hassan Jalali, Maryam Med J Islam Repub Iran Original Article Background: Drop foot syndrome is a disorder characterized by foot slapping after the initial contact and foot-dragging during the swing phase. Passive and hybrid passive ankle foot orthoses (AFOs) are often prescribed in these patients; however, the effects of these AFO designs on kinematic parameters during gait are unclear. The aim of this study was to compare the effect of innovative designed storing-restoring hybrid passive AFOs versus posterior leaf spring AFO on ankle joint kinematics in drop foot patients. Methods: The present study was a case series where a single case and 3 cases with drop foot syndrome were recruited. This study was designed in 2 phases: the baseline phase with their PLS AFOs and an intervention phase in which innovative designed AFO were assessed. Each phase included 5 measurement sessions which were performed in 5 consecutive weeks. The celeration line method was used to detect the significant differences between the phases. Results: The results of this study showed a significant increase in the kinematic angles parameters at the initial contact, the loading response, the mid stance, terminal stance, pre swing, initial swing, mid swing, and terminal swing with the innovative designed AFO than with PLS AFO (p<0.05). Conclusion: The results of the present study suggested that use of the innovative designed AFO may have a positive effect on ankle joint kinematics parameters in people with drop foot. Iran University of Medical Sciences 2020-12-21 /pmc/articles/PMC8004578/ /pubmed/33816372 http://dx.doi.org/10.47176/mjiri.34.173 Text en © 2020 Iran University of Medical Sciences http://creativecommons.org/licenses/by-nc-sa/1.0/ This is an open-access article distributed under the terms of the Creative Commons Attribution NonCommercial-ShareAlike 1.0 License (CC BY-NC-SA 1.0), which allows users to read, copy, distribute and make derivative works for non-commercial purposes from the material, as long as the author of the original work is cited properly. |
spellingShingle | Original Article Pourhoseingholi, Ensieh Kamali, Mohammad Saeedi, Hassan Jalali, Maryam The comparison of the effect of innovative designed storing-restoring hybrid passive AFO versus posterior leaf spring AFO on ankle joint kinematic in drop foot patients: A case series using a single subject design |
title | The comparison of the effect of innovative designed storing-restoring hybrid passive AFO versus posterior leaf spring AFO on ankle joint kinematic in drop foot patients: A case series using a single subject design |
title_full | The comparison of the effect of innovative designed storing-restoring hybrid passive AFO versus posterior leaf spring AFO on ankle joint kinematic in drop foot patients: A case series using a single subject design |
title_fullStr | The comparison of the effect of innovative designed storing-restoring hybrid passive AFO versus posterior leaf spring AFO on ankle joint kinematic in drop foot patients: A case series using a single subject design |
title_full_unstemmed | The comparison of the effect of innovative designed storing-restoring hybrid passive AFO versus posterior leaf spring AFO on ankle joint kinematic in drop foot patients: A case series using a single subject design |
title_short | The comparison of the effect of innovative designed storing-restoring hybrid passive AFO versus posterior leaf spring AFO on ankle joint kinematic in drop foot patients: A case series using a single subject design |
title_sort | comparison of the effect of innovative designed storing-restoring hybrid passive afo versus posterior leaf spring afo on ankle joint kinematic in drop foot patients: a case series using a single subject design |
topic | Original Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8004578/ https://www.ncbi.nlm.nih.gov/pubmed/33816372 http://dx.doi.org/10.47176/mjiri.34.173 |
work_keys_str_mv | AT pourhoseingholiensieh thecomparisonoftheeffectofinnovativedesignedstoringrestoringhybridpassiveafoversusposteriorleafspringafoonanklejointkinematicindropfootpatientsacaseseriesusingasinglesubjectdesign AT kamalimohammad thecomparisonoftheeffectofinnovativedesignedstoringrestoringhybridpassiveafoversusposteriorleafspringafoonanklejointkinematicindropfootpatientsacaseseriesusingasinglesubjectdesign AT saeedihassan thecomparisonoftheeffectofinnovativedesignedstoringrestoringhybridpassiveafoversusposteriorleafspringafoonanklejointkinematicindropfootpatientsacaseseriesusingasinglesubjectdesign AT jalalimaryam thecomparisonoftheeffectofinnovativedesignedstoringrestoringhybridpassiveafoversusposteriorleafspringafoonanklejointkinematicindropfootpatientsacaseseriesusingasinglesubjectdesign AT pourhoseingholiensieh comparisonoftheeffectofinnovativedesignedstoringrestoringhybridpassiveafoversusposteriorleafspringafoonanklejointkinematicindropfootpatientsacaseseriesusingasinglesubjectdesign AT kamalimohammad comparisonoftheeffectofinnovativedesignedstoringrestoringhybridpassiveafoversusposteriorleafspringafoonanklejointkinematicindropfootpatientsacaseseriesusingasinglesubjectdesign AT saeedihassan comparisonoftheeffectofinnovativedesignedstoringrestoringhybridpassiveafoversusposteriorleafspringafoonanklejointkinematicindropfootpatientsacaseseriesusingasinglesubjectdesign AT jalalimaryam comparisonoftheeffectofinnovativedesignedstoringrestoringhybridpassiveafoversusposteriorleafspringafoonanklejointkinematicindropfootpatientsacaseseriesusingasinglesubjectdesign |