Cargando…

The Effects of Sterilization Procedures on the Cutting Efficiency of Endodontic Instruments: A Systematic Review and Network Meta-Analysis

Sterilization processes guarantee the sterility of dental instruments but can negatively affect instrument features by altering their physical and mechanical properties. The endodontic instrumentation can undergo a series of alterations, ranging from corrosion to variation in the cutting angle and t...

Descripción completa

Detalles Bibliográficos
Autores principales: Dioguardi, Mario, Laneve, Enrica, Di Cosola, Michele, Cazzolla, Angela Pia, Sovereto, Diego, Aiuto, Riccardo, Laino, Luigi, Leanza, Teresa, Alovisi, Mario, Troiano, Giuseppe, Lo Muzio, Lorenzo
Formato: Online Artículo Texto
Lenguaje:English
Publicado: MDPI 2021
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8004799/
https://www.ncbi.nlm.nih.gov/pubmed/33810097
http://dx.doi.org/10.3390/ma14061559
_version_ 1783671985836916736
author Dioguardi, Mario
Laneve, Enrica
Di Cosola, Michele
Cazzolla, Angela Pia
Sovereto, Diego
Aiuto, Riccardo
Laino, Luigi
Leanza, Teresa
Alovisi, Mario
Troiano, Giuseppe
Lo Muzio, Lorenzo
author_facet Dioguardi, Mario
Laneve, Enrica
Di Cosola, Michele
Cazzolla, Angela Pia
Sovereto, Diego
Aiuto, Riccardo
Laino, Luigi
Leanza, Teresa
Alovisi, Mario
Troiano, Giuseppe
Lo Muzio, Lorenzo
author_sort Dioguardi, Mario
collection PubMed
description Sterilization processes guarantee the sterility of dental instruments but can negatively affect instrument features by altering their physical and mechanical properties. The endodontic instrumentation can undergo a series of alterations, ranging from corrosion to variation in the cutting angle and then changes in the torsional properties and torsional fatigue resistance. This systematic literature review and meta-analysis aims to investigate alterations to the cutting efficiency of endodontic instruments that are induced by procedures for their disinfection and sterilization. Methodologies adopted for this investigation follow the PRISMA (Preferred Reporting Items for Systematic Reviews and Meta-Analysis) guidelines. The following were used as search terms on PubMed and Scopus: “endodontic sterilization”, “endodontic autoclave”, “cyclic fatigue”, “torsional”, “cutting efficiency”, “sterilization”, “surface characteristics”, and “corrosion”. At the end of the selection process, 36 articles were identified, and seven of them are included in this systematic review. The results of a meta-analysis conducted for the use of 10 autoclaving cycles shows a standardized mean difference (SMD) of 0.80 with a p-value equal to 0.04 with respect to effect on cutting efficiency. The network meta-analysis, through direct and indirect comparison between the different autoclave cycles (0, 1, 5, 10, and 15 cycles), revealed that treatment involving 15 autoclave cycles produced the most robust results in terms of having the greatest effects in terms of altered cutting efficiency with a probability of 57.7% and a SUCRA (surface under the cumulative ranking) of 80%. The alterations in the effects on cutting efficiency appear to be triggered after five cycles of sterilization by heat (autoclave). In conclusion, the meta-analysis of the data indicates that the autoclave sterilization protocol must not be repeated more than five times to preserve cutting efficiency. Within the limitations of this review, we can therefore establish that sterilization by autoclaving alone results in steel and NiTi instruments becoming less efficient in cutting after five cycles, as measured by a reduction in cutting efficiency.
format Online
Article
Text
id pubmed-8004799
institution National Center for Biotechnology Information
language English
publishDate 2021
publisher MDPI
record_format MEDLINE/PubMed
spelling pubmed-80047992021-03-29 The Effects of Sterilization Procedures on the Cutting Efficiency of Endodontic Instruments: A Systematic Review and Network Meta-Analysis Dioguardi, Mario Laneve, Enrica Di Cosola, Michele Cazzolla, Angela Pia Sovereto, Diego Aiuto, Riccardo Laino, Luigi Leanza, Teresa Alovisi, Mario Troiano, Giuseppe Lo Muzio, Lorenzo Materials (Basel) Review Sterilization processes guarantee the sterility of dental instruments but can negatively affect instrument features by altering their physical and mechanical properties. The endodontic instrumentation can undergo a series of alterations, ranging from corrosion to variation in the cutting angle and then changes in the torsional properties and torsional fatigue resistance. This systematic literature review and meta-analysis aims to investigate alterations to the cutting efficiency of endodontic instruments that are induced by procedures for their disinfection and sterilization. Methodologies adopted for this investigation follow the PRISMA (Preferred Reporting Items for Systematic Reviews and Meta-Analysis) guidelines. The following were used as search terms on PubMed and Scopus: “endodontic sterilization”, “endodontic autoclave”, “cyclic fatigue”, “torsional”, “cutting efficiency”, “sterilization”, “surface characteristics”, and “corrosion”. At the end of the selection process, 36 articles were identified, and seven of them are included in this systematic review. The results of a meta-analysis conducted for the use of 10 autoclaving cycles shows a standardized mean difference (SMD) of 0.80 with a p-value equal to 0.04 with respect to effect on cutting efficiency. The network meta-analysis, through direct and indirect comparison between the different autoclave cycles (0, 1, 5, 10, and 15 cycles), revealed that treatment involving 15 autoclave cycles produced the most robust results in terms of having the greatest effects in terms of altered cutting efficiency with a probability of 57.7% and a SUCRA (surface under the cumulative ranking) of 80%. The alterations in the effects on cutting efficiency appear to be triggered after five cycles of sterilization by heat (autoclave). In conclusion, the meta-analysis of the data indicates that the autoclave sterilization protocol must not be repeated more than five times to preserve cutting efficiency. Within the limitations of this review, we can therefore establish that sterilization by autoclaving alone results in steel and NiTi instruments becoming less efficient in cutting after five cycles, as measured by a reduction in cutting efficiency. MDPI 2021-03-22 /pmc/articles/PMC8004799/ /pubmed/33810097 http://dx.doi.org/10.3390/ma14061559 Text en © 2021 by the authors. Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (http://creativecommons.org/licenses/by/4.0/).
spellingShingle Review
Dioguardi, Mario
Laneve, Enrica
Di Cosola, Michele
Cazzolla, Angela Pia
Sovereto, Diego
Aiuto, Riccardo
Laino, Luigi
Leanza, Teresa
Alovisi, Mario
Troiano, Giuseppe
Lo Muzio, Lorenzo
The Effects of Sterilization Procedures on the Cutting Efficiency of Endodontic Instruments: A Systematic Review and Network Meta-Analysis
title The Effects of Sterilization Procedures on the Cutting Efficiency of Endodontic Instruments: A Systematic Review and Network Meta-Analysis
title_full The Effects of Sterilization Procedures on the Cutting Efficiency of Endodontic Instruments: A Systematic Review and Network Meta-Analysis
title_fullStr The Effects of Sterilization Procedures on the Cutting Efficiency of Endodontic Instruments: A Systematic Review and Network Meta-Analysis
title_full_unstemmed The Effects of Sterilization Procedures on the Cutting Efficiency of Endodontic Instruments: A Systematic Review and Network Meta-Analysis
title_short The Effects of Sterilization Procedures on the Cutting Efficiency of Endodontic Instruments: A Systematic Review and Network Meta-Analysis
title_sort effects of sterilization procedures on the cutting efficiency of endodontic instruments: a systematic review and network meta-analysis
topic Review
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8004799/
https://www.ncbi.nlm.nih.gov/pubmed/33810097
http://dx.doi.org/10.3390/ma14061559
work_keys_str_mv AT dioguardimario theeffectsofsterilizationproceduresonthecuttingefficiencyofendodonticinstrumentsasystematicreviewandnetworkmetaanalysis
AT laneveenrica theeffectsofsterilizationproceduresonthecuttingefficiencyofendodonticinstrumentsasystematicreviewandnetworkmetaanalysis
AT dicosolamichele theeffectsofsterilizationproceduresonthecuttingefficiencyofendodonticinstrumentsasystematicreviewandnetworkmetaanalysis
AT cazzollaangelapia theeffectsofsterilizationproceduresonthecuttingefficiencyofendodonticinstrumentsasystematicreviewandnetworkmetaanalysis
AT soveretodiego theeffectsofsterilizationproceduresonthecuttingefficiencyofendodonticinstrumentsasystematicreviewandnetworkmetaanalysis
AT aiutoriccardo theeffectsofsterilizationproceduresonthecuttingefficiencyofendodonticinstrumentsasystematicreviewandnetworkmetaanalysis
AT lainoluigi theeffectsofsterilizationproceduresonthecuttingefficiencyofendodonticinstrumentsasystematicreviewandnetworkmetaanalysis
AT leanzateresa theeffectsofsterilizationproceduresonthecuttingefficiencyofendodonticinstrumentsasystematicreviewandnetworkmetaanalysis
AT alovisimario theeffectsofsterilizationproceduresonthecuttingefficiencyofendodonticinstrumentsasystematicreviewandnetworkmetaanalysis
AT troianogiuseppe theeffectsofsterilizationproceduresonthecuttingefficiencyofendodonticinstrumentsasystematicreviewandnetworkmetaanalysis
AT lomuziolorenzo theeffectsofsterilizationproceduresonthecuttingefficiencyofendodonticinstrumentsasystematicreviewandnetworkmetaanalysis
AT dioguardimario effectsofsterilizationproceduresonthecuttingefficiencyofendodonticinstrumentsasystematicreviewandnetworkmetaanalysis
AT laneveenrica effectsofsterilizationproceduresonthecuttingefficiencyofendodonticinstrumentsasystematicreviewandnetworkmetaanalysis
AT dicosolamichele effectsofsterilizationproceduresonthecuttingefficiencyofendodonticinstrumentsasystematicreviewandnetworkmetaanalysis
AT cazzollaangelapia effectsofsterilizationproceduresonthecuttingefficiencyofendodonticinstrumentsasystematicreviewandnetworkmetaanalysis
AT soveretodiego effectsofsterilizationproceduresonthecuttingefficiencyofendodonticinstrumentsasystematicreviewandnetworkmetaanalysis
AT aiutoriccardo effectsofsterilizationproceduresonthecuttingefficiencyofendodonticinstrumentsasystematicreviewandnetworkmetaanalysis
AT lainoluigi effectsofsterilizationproceduresonthecuttingefficiencyofendodonticinstrumentsasystematicreviewandnetworkmetaanalysis
AT leanzateresa effectsofsterilizationproceduresonthecuttingefficiencyofendodonticinstrumentsasystematicreviewandnetworkmetaanalysis
AT alovisimario effectsofsterilizationproceduresonthecuttingefficiencyofendodonticinstrumentsasystematicreviewandnetworkmetaanalysis
AT troianogiuseppe effectsofsterilizationproceduresonthecuttingefficiencyofendodonticinstrumentsasystematicreviewandnetworkmetaanalysis
AT lomuziolorenzo effectsofsterilizationproceduresonthecuttingefficiencyofendodonticinstrumentsasystematicreviewandnetworkmetaanalysis