Cargando…
Scanning Electron Microscopic Evaluation of the Internal Fit Accuracy of 3D-Printed Biphasic Calcium Phosphate Block: An Ex Vivo Pilot Study
The aim of this study was to assess the internal fit accuracy of a three-dimensional (3D)-printed biphasic calcium phosphate (BCP) block compared with a 3D-milled poly methyl methacrylate (PMMA) block by scanning electron microscope (SEM) analysis. In a total of 20 porcine rib bones, two different t...
Autores principales: | , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
MDPI
2021
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8004813/ https://www.ncbi.nlm.nih.gov/pubmed/33810060 http://dx.doi.org/10.3390/ma14061557 |
_version_ | 1783671989177679872 |
---|---|
author | Jeon, Su-Hee Song, Young Woo Cha, Jae-Kook Paik, Jeong-Won Han, Sang-Sun Choi, Seong-Ho |
author_facet | Jeon, Su-Hee Song, Young Woo Cha, Jae-Kook Paik, Jeong-Won Han, Sang-Sun Choi, Seong-Ho |
author_sort | Jeon, Su-Hee |
collection | PubMed |
description | The aim of this study was to assess the internal fit accuracy of a three-dimensional (3D)-printed biphasic calcium phosphate (BCP) block compared with a 3D-milled poly methyl methacrylate (PMMA) block by scanning electron microscope (SEM) analysis. In a total of 20 porcine rib bones, two different types of defects having two adjacent walls and a floor were produced: a defect with a flat floor (flat defect; N = 10) and a defect with a concave floor (curved defect; N = 10). Each defect was grafted with either the 3D-printed BCP block or the 3D-milled PMMA block fabricated following the computer aided design. The defects were then cut cross-sectionally and evaluated under the SEM. The extents of internal contact and gap were measured and statistically analyzed (p < 0.05). All blocks in both BCP and PMMA groups were successfully fit to the flat and curved defects. The internal contact ratio was significantly higher in the BCP group (flat defect: 0.47 ± 0.10; curved defect: 0.29 ± 0.05) compared with the PMMA group (flat defect: 0.21 ± 0.13; curved defect: 0.17 ± 0.04; p < 0.05). The internal gap area was similar between the two groups regardless of the defect types (p > 0.05). The internal fit accuracy of the 3D-printed BCP block was reliable in both the flat and curved defects when compared with the accuracy of the 3D-milled PMMA block. |
format | Online Article Text |
id | pubmed-8004813 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2021 |
publisher | MDPI |
record_format | MEDLINE/PubMed |
spelling | pubmed-80048132021-03-29 Scanning Electron Microscopic Evaluation of the Internal Fit Accuracy of 3D-Printed Biphasic Calcium Phosphate Block: An Ex Vivo Pilot Study Jeon, Su-Hee Song, Young Woo Cha, Jae-Kook Paik, Jeong-Won Han, Sang-Sun Choi, Seong-Ho Materials (Basel) Article The aim of this study was to assess the internal fit accuracy of a three-dimensional (3D)-printed biphasic calcium phosphate (BCP) block compared with a 3D-milled poly methyl methacrylate (PMMA) block by scanning electron microscope (SEM) analysis. In a total of 20 porcine rib bones, two different types of defects having two adjacent walls and a floor were produced: a defect with a flat floor (flat defect; N = 10) and a defect with a concave floor (curved defect; N = 10). Each defect was grafted with either the 3D-printed BCP block or the 3D-milled PMMA block fabricated following the computer aided design. The defects were then cut cross-sectionally and evaluated under the SEM. The extents of internal contact and gap were measured and statistically analyzed (p < 0.05). All blocks in both BCP and PMMA groups were successfully fit to the flat and curved defects. The internal contact ratio was significantly higher in the BCP group (flat defect: 0.47 ± 0.10; curved defect: 0.29 ± 0.05) compared with the PMMA group (flat defect: 0.21 ± 0.13; curved defect: 0.17 ± 0.04; p < 0.05). The internal gap area was similar between the two groups regardless of the defect types (p > 0.05). The internal fit accuracy of the 3D-printed BCP block was reliable in both the flat and curved defects when compared with the accuracy of the 3D-milled PMMA block. MDPI 2021-03-22 /pmc/articles/PMC8004813/ /pubmed/33810060 http://dx.doi.org/10.3390/ma14061557 Text en © 2021 by the authors. Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (http://creativecommons.org/licenses/by/4.0/). |
spellingShingle | Article Jeon, Su-Hee Song, Young Woo Cha, Jae-Kook Paik, Jeong-Won Han, Sang-Sun Choi, Seong-Ho Scanning Electron Microscopic Evaluation of the Internal Fit Accuracy of 3D-Printed Biphasic Calcium Phosphate Block: An Ex Vivo Pilot Study |
title | Scanning Electron Microscopic Evaluation of the Internal Fit Accuracy of 3D-Printed Biphasic Calcium Phosphate Block: An Ex Vivo Pilot Study |
title_full | Scanning Electron Microscopic Evaluation of the Internal Fit Accuracy of 3D-Printed Biphasic Calcium Phosphate Block: An Ex Vivo Pilot Study |
title_fullStr | Scanning Electron Microscopic Evaluation of the Internal Fit Accuracy of 3D-Printed Biphasic Calcium Phosphate Block: An Ex Vivo Pilot Study |
title_full_unstemmed | Scanning Electron Microscopic Evaluation of the Internal Fit Accuracy of 3D-Printed Biphasic Calcium Phosphate Block: An Ex Vivo Pilot Study |
title_short | Scanning Electron Microscopic Evaluation of the Internal Fit Accuracy of 3D-Printed Biphasic Calcium Phosphate Block: An Ex Vivo Pilot Study |
title_sort | scanning electron microscopic evaluation of the internal fit accuracy of 3d-printed biphasic calcium phosphate block: an ex vivo pilot study |
topic | Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8004813/ https://www.ncbi.nlm.nih.gov/pubmed/33810060 http://dx.doi.org/10.3390/ma14061557 |
work_keys_str_mv | AT jeonsuhee scanningelectronmicroscopicevaluationoftheinternalfitaccuracyof3dprintedbiphasiccalciumphosphateblockanexvivopilotstudy AT songyoungwoo scanningelectronmicroscopicevaluationoftheinternalfitaccuracyof3dprintedbiphasiccalciumphosphateblockanexvivopilotstudy AT chajaekook scanningelectronmicroscopicevaluationoftheinternalfitaccuracyof3dprintedbiphasiccalciumphosphateblockanexvivopilotstudy AT paikjeongwon scanningelectronmicroscopicevaluationoftheinternalfitaccuracyof3dprintedbiphasiccalciumphosphateblockanexvivopilotstudy AT hansangsun scanningelectronmicroscopicevaluationoftheinternalfitaccuracyof3dprintedbiphasiccalciumphosphateblockanexvivopilotstudy AT choiseongho scanningelectronmicroscopicevaluationoftheinternalfitaccuracyof3dprintedbiphasiccalciumphosphateblockanexvivopilotstudy |