Cargando…

Determination of split renal function in voluntary renal donors by multidetector computed tomography and nuclear renography: How well do they correlate?

BACKGROUND: The use of computed tomography (CT) for estimation of split renal function (SRF) has been reported previously. However, most of these studies have small samples, and many do not account for the renal attenuation at CT. OBJECTIVE: The aim of this study was to compare multidetector compute...

Descripción completa

Detalles Bibliográficos
Autores principales: Lal, Hira, Singh, Anuradha, Prasad, Raghunandan, Yadav, Priyank, Akhtar, Javed, Barai, Sukanta, Mishra, Prabhakar, Bhadauria, Dharmendra, Kaul, Anupma, Prasad, Narayan, Verma, Pragati
Formato: Online Artículo Texto
Lenguaje:English
Publicado: AOSIS 2021
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8008088/
https://www.ncbi.nlm.nih.gov/pubmed/33824742
http://dx.doi.org/10.4102/sajr.v25i1.2009
_version_ 1783672628013170688
author Lal, Hira
Singh, Anuradha
Prasad, Raghunandan
Yadav, Priyank
Akhtar, Javed
Barai, Sukanta
Mishra, Prabhakar
Bhadauria, Dharmendra
Kaul, Anupma
Prasad, Narayan
Verma, Pragati
author_facet Lal, Hira
Singh, Anuradha
Prasad, Raghunandan
Yadav, Priyank
Akhtar, Javed
Barai, Sukanta
Mishra, Prabhakar
Bhadauria, Dharmendra
Kaul, Anupma
Prasad, Narayan
Verma, Pragati
author_sort Lal, Hira
collection PubMed
description BACKGROUND: The use of computed tomography (CT) for estimation of split renal function (SRF) has been reported previously. However, most of these studies have small samples, and many do not account for the renal attenuation at CT. OBJECTIVE: The aim of this study was to compare multidetector computed tomography (MDCT) volumetry-attenuation-based SRF with that obtained via Tc99m-diethylenetriaminepentaacetic acid (DTPA) renal scintigraphy in voluntary renal donors. METHODS: Between January 2017 and January 2020, 526 voluntary renal donors were enrolled prospectively. All donors underwent contrast CT and DTPA scan before surgery. The semiautomatic region of interest (ROI) tool was applied slice by slice on axial CT images acquired in the arterial phase. The renal contour was drawn semiautomatically with mouse clicks around the renal parenchyma, and the renal volume was ascertained. Using renal volume and attenuation, SRF was determined and compared with results obtained at DTPA imaging. RESULTS: The mean age was 44.91 ± 10.97 years (mean ± s.d.). There was no significant difference in SRF based on DTPA and MDCT volumetry for the left kidney (49.18% ± 3.40% vs. 49.15% ± 3.38%, p = 0.540) and for the right kidney (50.82% ± 3.40% vs. 50.86% ± 3.39%, p = 0.358). A very good correlation was observed between the two methods for the left kidney (r = 0.953, p = 0.000) and the right kidney (r = 0.955, p = 0.000). On simple linear regression analysis, 90.8% of DTPA SRF values for the left kidney and 91.3% of DTPA SRF values for the right kidney could be predicted correctly using the corresponding MDCT SRF values. CONCLUSION: MDCT volumetry-attenuation-derived estimation of SRF for living renal donors could be an alternative to renal scintigraphy-based SRF estimation.
format Online
Article
Text
id pubmed-8008088
institution National Center for Biotechnology Information
language English
publishDate 2021
publisher AOSIS
record_format MEDLINE/PubMed
spelling pubmed-80080882021-04-05 Determination of split renal function in voluntary renal donors by multidetector computed tomography and nuclear renography: How well do they correlate? Lal, Hira Singh, Anuradha Prasad, Raghunandan Yadav, Priyank Akhtar, Javed Barai, Sukanta Mishra, Prabhakar Bhadauria, Dharmendra Kaul, Anupma Prasad, Narayan Verma, Pragati SA J Radiol Original Research BACKGROUND: The use of computed tomography (CT) for estimation of split renal function (SRF) has been reported previously. However, most of these studies have small samples, and many do not account for the renal attenuation at CT. OBJECTIVE: The aim of this study was to compare multidetector computed tomography (MDCT) volumetry-attenuation-based SRF with that obtained via Tc99m-diethylenetriaminepentaacetic acid (DTPA) renal scintigraphy in voluntary renal donors. METHODS: Between January 2017 and January 2020, 526 voluntary renal donors were enrolled prospectively. All donors underwent contrast CT and DTPA scan before surgery. The semiautomatic region of interest (ROI) tool was applied slice by slice on axial CT images acquired in the arterial phase. The renal contour was drawn semiautomatically with mouse clicks around the renal parenchyma, and the renal volume was ascertained. Using renal volume and attenuation, SRF was determined and compared with results obtained at DTPA imaging. RESULTS: The mean age was 44.91 ± 10.97 years (mean ± s.d.). There was no significant difference in SRF based on DTPA and MDCT volumetry for the left kidney (49.18% ± 3.40% vs. 49.15% ± 3.38%, p = 0.540) and for the right kidney (50.82% ± 3.40% vs. 50.86% ± 3.39%, p = 0.358). A very good correlation was observed between the two methods for the left kidney (r = 0.953, p = 0.000) and the right kidney (r = 0.955, p = 0.000). On simple linear regression analysis, 90.8% of DTPA SRF values for the left kidney and 91.3% of DTPA SRF values for the right kidney could be predicted correctly using the corresponding MDCT SRF values. CONCLUSION: MDCT volumetry-attenuation-derived estimation of SRF for living renal donors could be an alternative to renal scintigraphy-based SRF estimation. AOSIS 2021-03-05 /pmc/articles/PMC8008088/ /pubmed/33824742 http://dx.doi.org/10.4102/sajr.v25i1.2009 Text en © 2021. The Authors https://creativecommons.org/licenses/by/4.0/ Licensee: AOSIS. This work is licensed under the Creative Commons Attribution License.
spellingShingle Original Research
Lal, Hira
Singh, Anuradha
Prasad, Raghunandan
Yadav, Priyank
Akhtar, Javed
Barai, Sukanta
Mishra, Prabhakar
Bhadauria, Dharmendra
Kaul, Anupma
Prasad, Narayan
Verma, Pragati
Determination of split renal function in voluntary renal donors by multidetector computed tomography and nuclear renography: How well do they correlate?
title Determination of split renal function in voluntary renal donors by multidetector computed tomography and nuclear renography: How well do they correlate?
title_full Determination of split renal function in voluntary renal donors by multidetector computed tomography and nuclear renography: How well do they correlate?
title_fullStr Determination of split renal function in voluntary renal donors by multidetector computed tomography and nuclear renography: How well do they correlate?
title_full_unstemmed Determination of split renal function in voluntary renal donors by multidetector computed tomography and nuclear renography: How well do they correlate?
title_short Determination of split renal function in voluntary renal donors by multidetector computed tomography and nuclear renography: How well do they correlate?
title_sort determination of split renal function in voluntary renal donors by multidetector computed tomography and nuclear renography: how well do they correlate?
topic Original Research
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8008088/
https://www.ncbi.nlm.nih.gov/pubmed/33824742
http://dx.doi.org/10.4102/sajr.v25i1.2009
work_keys_str_mv AT lalhira determinationofsplitrenalfunctioninvoluntaryrenaldonorsbymultidetectorcomputedtomographyandnuclearrenographyhowwelldotheycorrelate
AT singhanuradha determinationofsplitrenalfunctioninvoluntaryrenaldonorsbymultidetectorcomputedtomographyandnuclearrenographyhowwelldotheycorrelate
AT prasadraghunandan determinationofsplitrenalfunctioninvoluntaryrenaldonorsbymultidetectorcomputedtomographyandnuclearrenographyhowwelldotheycorrelate
AT yadavpriyank determinationofsplitrenalfunctioninvoluntaryrenaldonorsbymultidetectorcomputedtomographyandnuclearrenographyhowwelldotheycorrelate
AT akhtarjaved determinationofsplitrenalfunctioninvoluntaryrenaldonorsbymultidetectorcomputedtomographyandnuclearrenographyhowwelldotheycorrelate
AT baraisukanta determinationofsplitrenalfunctioninvoluntaryrenaldonorsbymultidetectorcomputedtomographyandnuclearrenographyhowwelldotheycorrelate
AT mishraprabhakar determinationofsplitrenalfunctioninvoluntaryrenaldonorsbymultidetectorcomputedtomographyandnuclearrenographyhowwelldotheycorrelate
AT bhadauriadharmendra determinationofsplitrenalfunctioninvoluntaryrenaldonorsbymultidetectorcomputedtomographyandnuclearrenographyhowwelldotheycorrelate
AT kaulanupma determinationofsplitrenalfunctioninvoluntaryrenaldonorsbymultidetectorcomputedtomographyandnuclearrenographyhowwelldotheycorrelate
AT prasadnarayan determinationofsplitrenalfunctioninvoluntaryrenaldonorsbymultidetectorcomputedtomographyandnuclearrenographyhowwelldotheycorrelate
AT vermapragati determinationofsplitrenalfunctioninvoluntaryrenaldonorsbymultidetectorcomputedtomographyandnuclearrenographyhowwelldotheycorrelate