Determination of split renal function in voluntary renal donors by multidetector computed tomography and nuclear renography: How well do they correlate?
BACKGROUND: The use of computed tomography (CT) for estimation of split renal function (SRF) has been reported previously. However, most of these studies have small samples, and many do not account for the renal attenuation at CT. OBJECTIVE: The aim of this study was to compare multidetector compute...
Autores principales: | , , , , , , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
AOSIS
2021
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8008088/ https://www.ncbi.nlm.nih.gov/pubmed/33824742 http://dx.doi.org/10.4102/sajr.v25i1.2009 |
_version_ | 1783672628013170688 |
---|---|
author | Lal, Hira Singh, Anuradha Prasad, Raghunandan Yadav, Priyank Akhtar, Javed Barai, Sukanta Mishra, Prabhakar Bhadauria, Dharmendra Kaul, Anupma Prasad, Narayan Verma, Pragati |
author_facet | Lal, Hira Singh, Anuradha Prasad, Raghunandan Yadav, Priyank Akhtar, Javed Barai, Sukanta Mishra, Prabhakar Bhadauria, Dharmendra Kaul, Anupma Prasad, Narayan Verma, Pragati |
author_sort | Lal, Hira |
collection | PubMed |
description | BACKGROUND: The use of computed tomography (CT) for estimation of split renal function (SRF) has been reported previously. However, most of these studies have small samples, and many do not account for the renal attenuation at CT. OBJECTIVE: The aim of this study was to compare multidetector computed tomography (MDCT) volumetry-attenuation-based SRF with that obtained via Tc99m-diethylenetriaminepentaacetic acid (DTPA) renal scintigraphy in voluntary renal donors. METHODS: Between January 2017 and January 2020, 526 voluntary renal donors were enrolled prospectively. All donors underwent contrast CT and DTPA scan before surgery. The semiautomatic region of interest (ROI) tool was applied slice by slice on axial CT images acquired in the arterial phase. The renal contour was drawn semiautomatically with mouse clicks around the renal parenchyma, and the renal volume was ascertained. Using renal volume and attenuation, SRF was determined and compared with results obtained at DTPA imaging. RESULTS: The mean age was 44.91 ± 10.97 years (mean ± s.d.). There was no significant difference in SRF based on DTPA and MDCT volumetry for the left kidney (49.18% ± 3.40% vs. 49.15% ± 3.38%, p = 0.540) and for the right kidney (50.82% ± 3.40% vs. 50.86% ± 3.39%, p = 0.358). A very good correlation was observed between the two methods for the left kidney (r = 0.953, p = 0.000) and the right kidney (r = 0.955, p = 0.000). On simple linear regression analysis, 90.8% of DTPA SRF values for the left kidney and 91.3% of DTPA SRF values for the right kidney could be predicted correctly using the corresponding MDCT SRF values. CONCLUSION: MDCT volumetry-attenuation-derived estimation of SRF for living renal donors could be an alternative to renal scintigraphy-based SRF estimation. |
format | Online Article Text |
id | pubmed-8008088 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2021 |
publisher | AOSIS |
record_format | MEDLINE/PubMed |
spelling | pubmed-80080882021-04-05 Determination of split renal function in voluntary renal donors by multidetector computed tomography and nuclear renography: How well do they correlate? Lal, Hira Singh, Anuradha Prasad, Raghunandan Yadav, Priyank Akhtar, Javed Barai, Sukanta Mishra, Prabhakar Bhadauria, Dharmendra Kaul, Anupma Prasad, Narayan Verma, Pragati SA J Radiol Original Research BACKGROUND: The use of computed tomography (CT) for estimation of split renal function (SRF) has been reported previously. However, most of these studies have small samples, and many do not account for the renal attenuation at CT. OBJECTIVE: The aim of this study was to compare multidetector computed tomography (MDCT) volumetry-attenuation-based SRF with that obtained via Tc99m-diethylenetriaminepentaacetic acid (DTPA) renal scintigraphy in voluntary renal donors. METHODS: Between January 2017 and January 2020, 526 voluntary renal donors were enrolled prospectively. All donors underwent contrast CT and DTPA scan before surgery. The semiautomatic region of interest (ROI) tool was applied slice by slice on axial CT images acquired in the arterial phase. The renal contour was drawn semiautomatically with mouse clicks around the renal parenchyma, and the renal volume was ascertained. Using renal volume and attenuation, SRF was determined and compared with results obtained at DTPA imaging. RESULTS: The mean age was 44.91 ± 10.97 years (mean ± s.d.). There was no significant difference in SRF based on DTPA and MDCT volumetry for the left kidney (49.18% ± 3.40% vs. 49.15% ± 3.38%, p = 0.540) and for the right kidney (50.82% ± 3.40% vs. 50.86% ± 3.39%, p = 0.358). A very good correlation was observed between the two methods for the left kidney (r = 0.953, p = 0.000) and the right kidney (r = 0.955, p = 0.000). On simple linear regression analysis, 90.8% of DTPA SRF values for the left kidney and 91.3% of DTPA SRF values for the right kidney could be predicted correctly using the corresponding MDCT SRF values. CONCLUSION: MDCT volumetry-attenuation-derived estimation of SRF for living renal donors could be an alternative to renal scintigraphy-based SRF estimation. AOSIS 2021-03-05 /pmc/articles/PMC8008088/ /pubmed/33824742 http://dx.doi.org/10.4102/sajr.v25i1.2009 Text en © 2021. The Authors https://creativecommons.org/licenses/by/4.0/ Licensee: AOSIS. This work is licensed under the Creative Commons Attribution License. |
spellingShingle | Original Research Lal, Hira Singh, Anuradha Prasad, Raghunandan Yadav, Priyank Akhtar, Javed Barai, Sukanta Mishra, Prabhakar Bhadauria, Dharmendra Kaul, Anupma Prasad, Narayan Verma, Pragati Determination of split renal function in voluntary renal donors by multidetector computed tomography and nuclear renography: How well do they correlate? |
title | Determination of split renal function in voluntary renal donors by multidetector computed tomography and nuclear renography: How well do they correlate? |
title_full | Determination of split renal function in voluntary renal donors by multidetector computed tomography and nuclear renography: How well do they correlate? |
title_fullStr | Determination of split renal function in voluntary renal donors by multidetector computed tomography and nuclear renography: How well do they correlate? |
title_full_unstemmed | Determination of split renal function in voluntary renal donors by multidetector computed tomography and nuclear renography: How well do they correlate? |
title_short | Determination of split renal function in voluntary renal donors by multidetector computed tomography and nuclear renography: How well do they correlate? |
title_sort | determination of split renal function in voluntary renal donors by multidetector computed tomography and nuclear renography: how well do they correlate? |
topic | Original Research |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8008088/ https://www.ncbi.nlm.nih.gov/pubmed/33824742 http://dx.doi.org/10.4102/sajr.v25i1.2009 |
work_keys_str_mv | AT lalhira determinationofsplitrenalfunctioninvoluntaryrenaldonorsbymultidetectorcomputedtomographyandnuclearrenographyhowwelldotheycorrelate AT singhanuradha determinationofsplitrenalfunctioninvoluntaryrenaldonorsbymultidetectorcomputedtomographyandnuclearrenographyhowwelldotheycorrelate AT prasadraghunandan determinationofsplitrenalfunctioninvoluntaryrenaldonorsbymultidetectorcomputedtomographyandnuclearrenographyhowwelldotheycorrelate AT yadavpriyank determinationofsplitrenalfunctioninvoluntaryrenaldonorsbymultidetectorcomputedtomographyandnuclearrenographyhowwelldotheycorrelate AT akhtarjaved determinationofsplitrenalfunctioninvoluntaryrenaldonorsbymultidetectorcomputedtomographyandnuclearrenographyhowwelldotheycorrelate AT baraisukanta determinationofsplitrenalfunctioninvoluntaryrenaldonorsbymultidetectorcomputedtomographyandnuclearrenographyhowwelldotheycorrelate AT mishraprabhakar determinationofsplitrenalfunctioninvoluntaryrenaldonorsbymultidetectorcomputedtomographyandnuclearrenographyhowwelldotheycorrelate AT bhadauriadharmendra determinationofsplitrenalfunctioninvoluntaryrenaldonorsbymultidetectorcomputedtomographyandnuclearrenographyhowwelldotheycorrelate AT kaulanupma determinationofsplitrenalfunctioninvoluntaryrenaldonorsbymultidetectorcomputedtomographyandnuclearrenographyhowwelldotheycorrelate AT prasadnarayan determinationofsplitrenalfunctioninvoluntaryrenaldonorsbymultidetectorcomputedtomographyandnuclearrenographyhowwelldotheycorrelate AT vermapragati determinationofsplitrenalfunctioninvoluntaryrenaldonorsbymultidetectorcomputedtomographyandnuclearrenographyhowwelldotheycorrelate |