Cargando…
Experimental evaluation of super-resolution imaging and magnification choice in single-particle cryo-EM
The resolution of cryo-EM reconstructions is fundamentally limited by the Nyquist frequency, which is half the sampling frequency of the detector and depends upon the magnification used. In principle, super-resolution imaging should enable reconstructions to surpass the physical Nyquist limit by inc...
Autores principales: | , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Elsevier
2021
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8008246/ https://www.ncbi.nlm.nih.gov/pubmed/33817625 http://dx.doi.org/10.1016/j.yjsbx.2021.100047 |
_version_ | 1783672659708477440 |
---|---|
author | Feathers, J. Ryan Spoth, Katherine A. Fromme, J. Christopher |
author_facet | Feathers, J. Ryan Spoth, Katherine A. Fromme, J. Christopher |
author_sort | Feathers, J. Ryan |
collection | PubMed |
description | The resolution of cryo-EM reconstructions is fundamentally limited by the Nyquist frequency, which is half the sampling frequency of the detector and depends upon the magnification used. In principle, super-resolution imaging should enable reconstructions to surpass the physical Nyquist limit by increasing sampling frequency, yet there are few reports of reconstructions that do so. Here we directly examine the contribution of super-resolution information, obtained with the K3 direct electron detector using a 2-condenser microscope, to single-particle cryo-EM reconstructions surpassing the physical Nyquist limit. We also present a comparative analysis of a sample imaged at four different magnifications. This analysis demonstrates that lower magnifications can be beneficial, despite the loss of higher resolution signal, due to the increased number of particle images obtained. To highlight the potential utility of lower magnification data collection, we produced a 3.5 Å reconstruction of jack bean urease with particles from a single micrograph. |
format | Online Article Text |
id | pubmed-8008246 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2021 |
publisher | Elsevier |
record_format | MEDLINE/PubMed |
spelling | pubmed-80082462021-04-01 Experimental evaluation of super-resolution imaging and magnification choice in single-particle cryo-EM Feathers, J. Ryan Spoth, Katherine A. Fromme, J. Christopher J Struct Biol X Article The resolution of cryo-EM reconstructions is fundamentally limited by the Nyquist frequency, which is half the sampling frequency of the detector and depends upon the magnification used. In principle, super-resolution imaging should enable reconstructions to surpass the physical Nyquist limit by increasing sampling frequency, yet there are few reports of reconstructions that do so. Here we directly examine the contribution of super-resolution information, obtained with the K3 direct electron detector using a 2-condenser microscope, to single-particle cryo-EM reconstructions surpassing the physical Nyquist limit. We also present a comparative analysis of a sample imaged at four different magnifications. This analysis demonstrates that lower magnifications can be beneficial, despite the loss of higher resolution signal, due to the increased number of particle images obtained. To highlight the potential utility of lower magnification data collection, we produced a 3.5 Å reconstruction of jack bean urease with particles from a single micrograph. Elsevier 2021-03-13 /pmc/articles/PMC8008246/ /pubmed/33817625 http://dx.doi.org/10.1016/j.yjsbx.2021.100047 Text en © 2021 The Author(s) http://creativecommons.org/licenses/by-nc-nd/4.0/ This is an open access article under the CC BY-NC-ND license (http://creativecommons.org/licenses/by-nc-nd/4.0/). |
spellingShingle | Article Feathers, J. Ryan Spoth, Katherine A. Fromme, J. Christopher Experimental evaluation of super-resolution imaging and magnification choice in single-particle cryo-EM |
title | Experimental evaluation of super-resolution imaging and magnification choice in single-particle cryo-EM |
title_full | Experimental evaluation of super-resolution imaging and magnification choice in single-particle cryo-EM |
title_fullStr | Experimental evaluation of super-resolution imaging and magnification choice in single-particle cryo-EM |
title_full_unstemmed | Experimental evaluation of super-resolution imaging and magnification choice in single-particle cryo-EM |
title_short | Experimental evaluation of super-resolution imaging and magnification choice in single-particle cryo-EM |
title_sort | experimental evaluation of super-resolution imaging and magnification choice in single-particle cryo-em |
topic | Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8008246/ https://www.ncbi.nlm.nih.gov/pubmed/33817625 http://dx.doi.org/10.1016/j.yjsbx.2021.100047 |
work_keys_str_mv | AT feathersjryan experimentalevaluationofsuperresolutionimagingandmagnificationchoiceinsingleparticlecryoem AT spothkatherinea experimentalevaluationofsuperresolutionimagingandmagnificationchoiceinsingleparticlecryoem AT frommejchristopher experimentalevaluationofsuperresolutionimagingandmagnificationchoiceinsingleparticlecryoem |