Cargando…

Dynamic External Pelvimetry Test in Third Trimester Pregnant Women: Shifting Positions Affect Pelvic Biomechanics and Create More Room in Obstetric Diameters

Dystocia in labor is still a clinical challenge. The "contracted pelvis" is the absence of pelvic mobility, which leads to fetal-pelvic disproportion, obstructed labor, and operative delivery. Maternal pelvis biomechanics studies by high technological techniques have shown that maternal sh...

Descripción completa

Detalles Bibliográficos
Autores principales: Siccardi, Marco, Valle, Cristina, Di Matteo, Fiorenza
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Cureus 2021
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8011468/
https://www.ncbi.nlm.nih.gov/pubmed/33816030
http://dx.doi.org/10.7759/cureus.13631
_version_ 1783673232132407296
author Siccardi, Marco
Valle, Cristina
Di Matteo, Fiorenza
author_facet Siccardi, Marco
Valle, Cristina
Di Matteo, Fiorenza
author_sort Siccardi, Marco
collection PubMed
description Dystocia in labor is still a clinical challenge. The "contracted pelvis" is the absence of pelvic mobility, which leads to fetal-pelvic disproportion, obstructed labor, and operative delivery. Maternal pelvis biomechanics studies by high technological techniques have shown that maternal shifting positions during pregnancy and labor can create more room in the pelvis for safe delivery. The external and internal pelvic diameters are related. The present study aims to evaluate the external obstetric pelvic diameters in shifting positions using a clinical technique suitable for daily practice in every clinical setting: the dynamic external pelvimetry test (DEP test). Seventy pregnant women were recruited, and the obstetric external pelvic diameters were measured, moving the position from kneeling standing to "hands-and-knees" to kneeling squat position. Results showed modification of the pelvic diameters in shifting position: the transverse and longitudinal diameters of Michaelis sacral area, the inter-tuberosities diameter, the bi-trochanters diameter, and the external conjugate widened; the bi-crestal iliac diameter, the bi-spinous iliac diameter, and the base of the Trillat's triangle decreased. The test showed good reproducibility and reliability. Linear correlations were found between diameters and between the range of motion of the diameters. The maternal pelvis is confirmed to modify the diameters changing its tridimensional shape. The pelvic inlet edge's inclination is inferred to be modified, facilitating the fetal descend. The pelvic outlet enlarged the transverse diameter, facilitating birth. The DEP test estimates the pelvic diameters' modification with postural changes, as magnetic resonance (MR) and computational biomechanics studies have demonstrated.
format Online
Article
Text
id pubmed-8011468
institution National Center for Biotechnology Information
language English
publishDate 2021
publisher Cureus
record_format MEDLINE/PubMed
spelling pubmed-80114682021-04-02 Dynamic External Pelvimetry Test in Third Trimester Pregnant Women: Shifting Positions Affect Pelvic Biomechanics and Create More Room in Obstetric Diameters Siccardi, Marco Valle, Cristina Di Matteo, Fiorenza Cureus Family/General Practice Dystocia in labor is still a clinical challenge. The "contracted pelvis" is the absence of pelvic mobility, which leads to fetal-pelvic disproportion, obstructed labor, and operative delivery. Maternal pelvis biomechanics studies by high technological techniques have shown that maternal shifting positions during pregnancy and labor can create more room in the pelvis for safe delivery. The external and internal pelvic diameters are related. The present study aims to evaluate the external obstetric pelvic diameters in shifting positions using a clinical technique suitable for daily practice in every clinical setting: the dynamic external pelvimetry test (DEP test). Seventy pregnant women were recruited, and the obstetric external pelvic diameters were measured, moving the position from kneeling standing to "hands-and-knees" to kneeling squat position. Results showed modification of the pelvic diameters in shifting position: the transverse and longitudinal diameters of Michaelis sacral area, the inter-tuberosities diameter, the bi-trochanters diameter, and the external conjugate widened; the bi-crestal iliac diameter, the bi-spinous iliac diameter, and the base of the Trillat's triangle decreased. The test showed good reproducibility and reliability. Linear correlations were found between diameters and between the range of motion of the diameters. The maternal pelvis is confirmed to modify the diameters changing its tridimensional shape. The pelvic inlet edge's inclination is inferred to be modified, facilitating the fetal descend. The pelvic outlet enlarged the transverse diameter, facilitating birth. The DEP test estimates the pelvic diameters' modification with postural changes, as magnetic resonance (MR) and computational biomechanics studies have demonstrated. Cureus 2021-03-01 /pmc/articles/PMC8011468/ /pubmed/33816030 http://dx.doi.org/10.7759/cureus.13631 Text en Copyright © 2021, Siccardi et al. http://creativecommons.org/licenses/by/3.0/ This is an open access article distributed under the terms of the Creative Commons Attribution License, which permits unrestricted use, distribution, and reproduction in any medium, provided the original author and source are credited.
spellingShingle Family/General Practice
Siccardi, Marco
Valle, Cristina
Di Matteo, Fiorenza
Dynamic External Pelvimetry Test in Third Trimester Pregnant Women: Shifting Positions Affect Pelvic Biomechanics and Create More Room in Obstetric Diameters
title Dynamic External Pelvimetry Test in Third Trimester Pregnant Women: Shifting Positions Affect Pelvic Biomechanics and Create More Room in Obstetric Diameters
title_full Dynamic External Pelvimetry Test in Third Trimester Pregnant Women: Shifting Positions Affect Pelvic Biomechanics and Create More Room in Obstetric Diameters
title_fullStr Dynamic External Pelvimetry Test in Third Trimester Pregnant Women: Shifting Positions Affect Pelvic Biomechanics and Create More Room in Obstetric Diameters
title_full_unstemmed Dynamic External Pelvimetry Test in Third Trimester Pregnant Women: Shifting Positions Affect Pelvic Biomechanics and Create More Room in Obstetric Diameters
title_short Dynamic External Pelvimetry Test in Third Trimester Pregnant Women: Shifting Positions Affect Pelvic Biomechanics and Create More Room in Obstetric Diameters
title_sort dynamic external pelvimetry test in third trimester pregnant women: shifting positions affect pelvic biomechanics and create more room in obstetric diameters
topic Family/General Practice
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8011468/
https://www.ncbi.nlm.nih.gov/pubmed/33816030
http://dx.doi.org/10.7759/cureus.13631
work_keys_str_mv AT siccardimarco dynamicexternalpelvimetrytestinthirdtrimesterpregnantwomenshiftingpositionsaffectpelvicbiomechanicsandcreatemoreroominobstetricdiameters
AT vallecristina dynamicexternalpelvimetrytestinthirdtrimesterpregnantwomenshiftingpositionsaffectpelvicbiomechanicsandcreatemoreroominobstetricdiameters
AT dimatteofiorenza dynamicexternalpelvimetrytestinthirdtrimesterpregnantwomenshiftingpositionsaffectpelvicbiomechanicsandcreatemoreroominobstetricdiameters