Cargando…
Smart contact lens and transparent heat patch for remote monitoring and therapy of chronic ocular surface inflammation using mobiles
Wearable electronic devices that can monitor physiological signals of the human body to provide biomedical information have been drawing extensive interests for sustainable personal health management. Here, we report a human pilot trial of a soft, smart contact lens and a skin-attachable therapeutic...
Autores principales: | , , , , , , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
American Association for the Advancement of Science
2021
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8011975/ https://www.ncbi.nlm.nih.gov/pubmed/33789904 http://dx.doi.org/10.1126/sciadv.abf7194 |
_version_ | 1783673295027044352 |
---|---|
author | Jang, Jiuk Kim, Joohee Shin, Haein Park, Young-Geun Joo, Byung Jun Seo, Hunkyu Won, Jong-eun Kim, Dai Woo Lee, Chang Young Kim, Hong Kyun Park, Jang-Ung |
author_facet | Jang, Jiuk Kim, Joohee Shin, Haein Park, Young-Geun Joo, Byung Jun Seo, Hunkyu Won, Jong-eun Kim, Dai Woo Lee, Chang Young Kim, Hong Kyun Park, Jang-Ung |
author_sort | Jang, Jiuk |
collection | PubMed |
description | Wearable electronic devices that can monitor physiological signals of the human body to provide biomedical information have been drawing extensive interests for sustainable personal health management. Here, we report a human pilot trial of a soft, smart contact lens and a skin-attachable therapeutic device for wireless monitoring and therapy of chronic ocular surface inflammation (OSI). As a diagnostic device, this smart contact lens enables real-time measurement of the concentration of matrix metalloproteinase-9, a biomarker for OSI, in tears using a graphene field-effect transistor. As a therapeutic device, we also fabricated a stretchable and transparent heat patch attachable on the human eyelid conformably. Both diagnostic and therapeutic devices can be incorporated using a smartphone for their wireless communications, thereby achieving instantaneous diagnosis of OSI and automated hyperthermia treatments. Furthermore, in vivo tests using live animals and human subjects confirm their good biocompatibility and reliability as a noninvasive, mobile health care solution. |
format | Online Article Text |
id | pubmed-8011975 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2021 |
publisher | American Association for the Advancement of Science |
record_format | MEDLINE/PubMed |
spelling | pubmed-80119752021-04-13 Smart contact lens and transparent heat patch for remote monitoring and therapy of chronic ocular surface inflammation using mobiles Jang, Jiuk Kim, Joohee Shin, Haein Park, Young-Geun Joo, Byung Jun Seo, Hunkyu Won, Jong-eun Kim, Dai Woo Lee, Chang Young Kim, Hong Kyun Park, Jang-Ung Sci Adv Research Articles Wearable electronic devices that can monitor physiological signals of the human body to provide biomedical information have been drawing extensive interests for sustainable personal health management. Here, we report a human pilot trial of a soft, smart contact lens and a skin-attachable therapeutic device for wireless monitoring and therapy of chronic ocular surface inflammation (OSI). As a diagnostic device, this smart contact lens enables real-time measurement of the concentration of matrix metalloproteinase-9, a biomarker for OSI, in tears using a graphene field-effect transistor. As a therapeutic device, we also fabricated a stretchable and transparent heat patch attachable on the human eyelid conformably. Both diagnostic and therapeutic devices can be incorporated using a smartphone for their wireless communications, thereby achieving instantaneous diagnosis of OSI and automated hyperthermia treatments. Furthermore, in vivo tests using live animals and human subjects confirm their good biocompatibility and reliability as a noninvasive, mobile health care solution. American Association for the Advancement of Science 2021-03-31 /pmc/articles/PMC8011975/ /pubmed/33789904 http://dx.doi.org/10.1126/sciadv.abf7194 Text en Copyright © 2021 The Authors, some rights reserved; exclusive licensee American Association for the Advancement of Science. No claim to original U.S. Government Works. Distributed under a Creative Commons Attribution NonCommercial License 4.0 (CC BY-NC). https://creativecommons.org/licenses/by-nc/4.0/ https://creativecommons.org/licenses/by-nc/4.0/This is an open-access article distributed under the terms of the Creative Commons Attribution-NonCommercial license (https://creativecommons.org/licenses/by-nc/4.0/) , which permits use, distribution, and reproduction in any medium, so long as the resultant use is not for commercial advantage and provided the original work is properly cited. |
spellingShingle | Research Articles Jang, Jiuk Kim, Joohee Shin, Haein Park, Young-Geun Joo, Byung Jun Seo, Hunkyu Won, Jong-eun Kim, Dai Woo Lee, Chang Young Kim, Hong Kyun Park, Jang-Ung Smart contact lens and transparent heat patch for remote monitoring and therapy of chronic ocular surface inflammation using mobiles |
title | Smart contact lens and transparent heat patch for remote monitoring and therapy of chronic ocular surface inflammation using mobiles |
title_full | Smart contact lens and transparent heat patch for remote monitoring and therapy of chronic ocular surface inflammation using mobiles |
title_fullStr | Smart contact lens and transparent heat patch for remote monitoring and therapy of chronic ocular surface inflammation using mobiles |
title_full_unstemmed | Smart contact lens and transparent heat patch for remote monitoring and therapy of chronic ocular surface inflammation using mobiles |
title_short | Smart contact lens and transparent heat patch for remote monitoring and therapy of chronic ocular surface inflammation using mobiles |
title_sort | smart contact lens and transparent heat patch for remote monitoring and therapy of chronic ocular surface inflammation using mobiles |
topic | Research Articles |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8011975/ https://www.ncbi.nlm.nih.gov/pubmed/33789904 http://dx.doi.org/10.1126/sciadv.abf7194 |
work_keys_str_mv | AT jangjiuk smartcontactlensandtransparentheatpatchforremotemonitoringandtherapyofchronicocularsurfaceinflammationusingmobiles AT kimjoohee smartcontactlensandtransparentheatpatchforremotemonitoringandtherapyofchronicocularsurfaceinflammationusingmobiles AT shinhaein smartcontactlensandtransparentheatpatchforremotemonitoringandtherapyofchronicocularsurfaceinflammationusingmobiles AT parkyounggeun smartcontactlensandtransparentheatpatchforremotemonitoringandtherapyofchronicocularsurfaceinflammationusingmobiles AT joobyungjun smartcontactlensandtransparentheatpatchforremotemonitoringandtherapyofchronicocularsurfaceinflammationusingmobiles AT seohunkyu smartcontactlensandtransparentheatpatchforremotemonitoringandtherapyofchronicocularsurfaceinflammationusingmobiles AT wonjongeun smartcontactlensandtransparentheatpatchforremotemonitoringandtherapyofchronicocularsurfaceinflammationusingmobiles AT kimdaiwoo smartcontactlensandtransparentheatpatchforremotemonitoringandtherapyofchronicocularsurfaceinflammationusingmobiles AT leechangyoung smartcontactlensandtransparentheatpatchforremotemonitoringandtherapyofchronicocularsurfaceinflammationusingmobiles AT kimhongkyun smartcontactlensandtransparentheatpatchforremotemonitoringandtherapyofchronicocularsurfaceinflammationusingmobiles AT parkjangung smartcontactlensandtransparentheatpatchforremotemonitoringandtherapyofchronicocularsurfaceinflammationusingmobiles |