Cargando…
Cut-off values of serum IgG4 among three reagents, including a novel IgG4 reagent: a multicenter study
Elevated serum IgG4 is a useful marker of IgG4-related disease (IgG4-RD) activity. However, there is no uniformity in the cut-off values of IgG4 among the various reagents. The aim of this study was to compare the measured and cut-off values of IgG4 assessed using three different reagents. This stud...
Autores principales: | , , , , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Nature Publishing Group UK
2021
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8012344/ https://www.ncbi.nlm.nih.gov/pubmed/33790306 http://dx.doi.org/10.1038/s41598-021-86024-5 |
_version_ | 1783673351126908928 |
---|---|
author | Usami, Yoko Sugano, Mitsutoshi Uehara, Takeshi Koinuma, Masayoshi Ishimine, Nau Kawasaki, Kenji Yamauchi, Kazuyoshi Hamano, Hideaki Honda, Takayuki |
author_facet | Usami, Yoko Sugano, Mitsutoshi Uehara, Takeshi Koinuma, Masayoshi Ishimine, Nau Kawasaki, Kenji Yamauchi, Kazuyoshi Hamano, Hideaki Honda, Takayuki |
author_sort | Usami, Yoko |
collection | PubMed |
description | Elevated serum IgG4 is a useful marker of IgG4-related disease (IgG4-RD) activity. However, there is no uniformity in the cut-off values of IgG4 among the various reagents. The aim of this study was to compare the measured and cut-off values of IgG4 assessed using three different reagents. This study enrolled 466 IgG4-RD and non-IgG4-RD patients who required measurement of serum IgG4 levels to diagnose or treat IgG4-RD. Serum IgG4 was measured using three reagents: N-assay LA IgG4 Nittobo (Nittobo), BS-NIA IgG4 (TBS), and N Latex IgG4 (Siemens). The values obtained using the three reagents were compared, and cut-off values were calculated for each. Although there was good correlation among the results with the three reagents, the measured and cut-off values were all different. The Nittobo values were 1.4 times the TBS values and the TBS values were almost half those of the Siemens values. ROC curve analysis showed cut-off values for the Nittobo, TBS, and Siemens reagents of 1.42, 1.31, and 2.38 g/L, respectively. The measured and cut-off values of serum IgG4 vary depending on the reagents used for the assay, although there is good correlation among the values measured by the three reagents. |
format | Online Article Text |
id | pubmed-8012344 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2021 |
publisher | Nature Publishing Group UK |
record_format | MEDLINE/PubMed |
spelling | pubmed-80123442021-04-01 Cut-off values of serum IgG4 among three reagents, including a novel IgG4 reagent: a multicenter study Usami, Yoko Sugano, Mitsutoshi Uehara, Takeshi Koinuma, Masayoshi Ishimine, Nau Kawasaki, Kenji Yamauchi, Kazuyoshi Hamano, Hideaki Honda, Takayuki Sci Rep Article Elevated serum IgG4 is a useful marker of IgG4-related disease (IgG4-RD) activity. However, there is no uniformity in the cut-off values of IgG4 among the various reagents. The aim of this study was to compare the measured and cut-off values of IgG4 assessed using three different reagents. This study enrolled 466 IgG4-RD and non-IgG4-RD patients who required measurement of serum IgG4 levels to diagnose or treat IgG4-RD. Serum IgG4 was measured using three reagents: N-assay LA IgG4 Nittobo (Nittobo), BS-NIA IgG4 (TBS), and N Latex IgG4 (Siemens). The values obtained using the three reagents were compared, and cut-off values were calculated for each. Although there was good correlation among the results with the three reagents, the measured and cut-off values were all different. The Nittobo values were 1.4 times the TBS values and the TBS values were almost half those of the Siemens values. ROC curve analysis showed cut-off values for the Nittobo, TBS, and Siemens reagents of 1.42, 1.31, and 2.38 g/L, respectively. The measured and cut-off values of serum IgG4 vary depending on the reagents used for the assay, although there is good correlation among the values measured by the three reagents. Nature Publishing Group UK 2021-03-31 /pmc/articles/PMC8012344/ /pubmed/33790306 http://dx.doi.org/10.1038/s41598-021-86024-5 Text en © The Author(s) 2021 Open Access This article is licensed under a Creative Commons Attribution 4.0 International License, which permits use, sharing, adaptation, distribution and reproduction in any medium or format, as long as you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons licence, and indicate if changes were made. The images or other third party material in this article are included in the article's Creative Commons licence, unless indicated otherwise in a credit line to the material. If material is not included in the article's Creative Commons licence and your intended use is not permitted by statutory regulation or exceeds the permitted use, you will need to obtain permission directly from the copyright holder. To view a copy of this licence, visit http://creativecommons.org/licenses/by/4.0/. |
spellingShingle | Article Usami, Yoko Sugano, Mitsutoshi Uehara, Takeshi Koinuma, Masayoshi Ishimine, Nau Kawasaki, Kenji Yamauchi, Kazuyoshi Hamano, Hideaki Honda, Takayuki Cut-off values of serum IgG4 among three reagents, including a novel IgG4 reagent: a multicenter study |
title | Cut-off values of serum IgG4 among three reagents, including a novel IgG4 reagent: a multicenter study |
title_full | Cut-off values of serum IgG4 among three reagents, including a novel IgG4 reagent: a multicenter study |
title_fullStr | Cut-off values of serum IgG4 among three reagents, including a novel IgG4 reagent: a multicenter study |
title_full_unstemmed | Cut-off values of serum IgG4 among three reagents, including a novel IgG4 reagent: a multicenter study |
title_short | Cut-off values of serum IgG4 among three reagents, including a novel IgG4 reagent: a multicenter study |
title_sort | cut-off values of serum igg4 among three reagents, including a novel igg4 reagent: a multicenter study |
topic | Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8012344/ https://www.ncbi.nlm.nih.gov/pubmed/33790306 http://dx.doi.org/10.1038/s41598-021-86024-5 |
work_keys_str_mv | AT usamiyoko cutoffvaluesofserumigg4amongthreereagentsincludinganoveligg4reagentamulticenterstudy AT suganomitsutoshi cutoffvaluesofserumigg4amongthreereagentsincludinganoveligg4reagentamulticenterstudy AT ueharatakeshi cutoffvaluesofserumigg4amongthreereagentsincludinganoveligg4reagentamulticenterstudy AT koinumamasayoshi cutoffvaluesofserumigg4amongthreereagentsincludinganoveligg4reagentamulticenterstudy AT ishiminenau cutoffvaluesofserumigg4amongthreereagentsincludinganoveligg4reagentamulticenterstudy AT kawasakikenji cutoffvaluesofserumigg4amongthreereagentsincludinganoveligg4reagentamulticenterstudy AT yamauchikazuyoshi cutoffvaluesofserumigg4amongthreereagentsincludinganoveligg4reagentamulticenterstudy AT hamanohideaki cutoffvaluesofserumigg4amongthreereagentsincludinganoveligg4reagentamulticenterstudy AT hondatakayuki cutoffvaluesofserumigg4amongthreereagentsincludinganoveligg4reagentamulticenterstudy |