Cargando…

Concurrent Validation and Reference Values of Gluteus Medius Clinical Test

CONTEXT: The hip abductor muscles, mainly the gluteus medius, are responsible for controlling hip adduction in a closed kinetic chain. Frontal plane knee alignment, assessed during functional activities such squatting, jumping and running, may overload joint structures, like the anterior cruciate li...

Descripción completa

Detalles Bibliográficos
Autores principales: Teixeira, Amanda S S, Silva, Paula L, Cintra, Sabrina P, Viegas, Fernanda, Mendonça, Luciana D, Bittencourt, Natália F N
Formato: Online Artículo Texto
Lenguaje:English
Publicado: NASMI 2021
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8016418/
https://www.ncbi.nlm.nih.gov/pubmed/33842029
http://dx.doi.org/10.26603/001c.21477
_version_ 1783673856384303104
author Teixeira, Amanda S S
Silva, Paula L
Cintra, Sabrina P
Viegas, Fernanda
Mendonça, Luciana D
Bittencourt, Natália F N
author_facet Teixeira, Amanda S S
Silva, Paula L
Cintra, Sabrina P
Viegas, Fernanda
Mendonça, Luciana D
Bittencourt, Natália F N
author_sort Teixeira, Amanda S S
collection PubMed
description CONTEXT: The hip abductor muscles, mainly the gluteus medius, are responsible for controlling hip adduction in a closed kinetic chain. Frontal plane knee alignment, assessed during functional activities such squatting, jumping and running, may overload joint structures, like the anterior cruciate ligament and patellofemoral joint. The hand-held dynamometer is reliable and effective for testing the muscular strength of the hip abductors. OBJECTIVES: 1. To assess the concurrent validity between the gluteus medius clinical test and a maximum isometric force test of the hip abductors using the hand-held dynamometer; (2) to determine the intra and inter-examiner reliability for the application of the gluteus medius clinical test; and (3) to describe reference values of gluteus medius clinical test on a population of youth athletes. DESIGN: Cross-sectional. METHODS: Thirty healthy individuals were recruited for validity and reliability testing. On the first day, participants performed the maximal isometric test of the hip abductors, measured via hand-held dynamometry. On the following week, the gluteus medius clinical test was performed. Intraclass correlation coefficients (ICC(2,2)) were computed for the reliability analysis, with a 95% confidence interval. To generate reference values, the gluteus medius clinical test was performed on 273 athletes. RESULTS: The results of this study indicated a weak positive correlation (r = 0.436, p = 0.001) between tests, which indicates that they examine different domains of gluteus medius muscle function, likely endurance and muscle strength. The magnitude of computed ICCs (>0.95) indicates excellent intra- and inter-examiner reliability. CONCLUSION: The findings of the current study indicate that the gluteus medius clinical test is reliable and examines a domain of muscular function not fully captured by HHD. The clinical test developed in this study is low-cost and can be included for gluteus medius assessment. LEVEL OF EVIDENCE: Level 3.
format Online
Article
Text
id pubmed-8016418
institution National Center for Biotechnology Information
language English
publishDate 2021
publisher NASMI
record_format MEDLINE/PubMed
spelling pubmed-80164182021-04-08 Concurrent Validation and Reference Values of Gluteus Medius Clinical Test Teixeira, Amanda S S Silva, Paula L Cintra, Sabrina P Viegas, Fernanda Mendonça, Luciana D Bittencourt, Natália F N Int J Sports Phys Ther Original Research CONTEXT: The hip abductor muscles, mainly the gluteus medius, are responsible for controlling hip adduction in a closed kinetic chain. Frontal plane knee alignment, assessed during functional activities such squatting, jumping and running, may overload joint structures, like the anterior cruciate ligament and patellofemoral joint. The hand-held dynamometer is reliable and effective for testing the muscular strength of the hip abductors. OBJECTIVES: 1. To assess the concurrent validity between the gluteus medius clinical test and a maximum isometric force test of the hip abductors using the hand-held dynamometer; (2) to determine the intra and inter-examiner reliability for the application of the gluteus medius clinical test; and (3) to describe reference values of gluteus medius clinical test on a population of youth athletes. DESIGN: Cross-sectional. METHODS: Thirty healthy individuals were recruited for validity and reliability testing. On the first day, participants performed the maximal isometric test of the hip abductors, measured via hand-held dynamometry. On the following week, the gluteus medius clinical test was performed. Intraclass correlation coefficients (ICC(2,2)) were computed for the reliability analysis, with a 95% confidence interval. To generate reference values, the gluteus medius clinical test was performed on 273 athletes. RESULTS: The results of this study indicated a weak positive correlation (r = 0.436, p = 0.001) between tests, which indicates that they examine different domains of gluteus medius muscle function, likely endurance and muscle strength. The magnitude of computed ICCs (>0.95) indicates excellent intra- and inter-examiner reliability. CONCLUSION: The findings of the current study indicate that the gluteus medius clinical test is reliable and examines a domain of muscular function not fully captured by HHD. The clinical test developed in this study is low-cost and can be included for gluteus medius assessment. LEVEL OF EVIDENCE: Level 3. NASMI 2021-04-01 /pmc/articles/PMC8016418/ /pubmed/33842029 http://dx.doi.org/10.26603/001c.21477 Text en https://creativecommons.org/licenses/by-nc-sa/4.0/ This is an open access article distributed under the terms of the Creative Commons Attribution-NonCommercial-ShareAlike License (4.0) (https://creativecommons.org/licenses/by-nc-sa/4.0/) which permits non-commercial use, distribution, and reproduction in any medium, provided the original author and source are credited. If you remix, transform, or build upon this work, you must distribute your contributions under the same license as the original.
spellingShingle Original Research
Teixeira, Amanda S S
Silva, Paula L
Cintra, Sabrina P
Viegas, Fernanda
Mendonça, Luciana D
Bittencourt, Natália F N
Concurrent Validation and Reference Values of Gluteus Medius Clinical Test
title Concurrent Validation and Reference Values of Gluteus Medius Clinical Test
title_full Concurrent Validation and Reference Values of Gluteus Medius Clinical Test
title_fullStr Concurrent Validation and Reference Values of Gluteus Medius Clinical Test
title_full_unstemmed Concurrent Validation and Reference Values of Gluteus Medius Clinical Test
title_short Concurrent Validation and Reference Values of Gluteus Medius Clinical Test
title_sort concurrent validation and reference values of gluteus medius clinical test
topic Original Research
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8016418/
https://www.ncbi.nlm.nih.gov/pubmed/33842029
http://dx.doi.org/10.26603/001c.21477
work_keys_str_mv AT teixeiraamandass concurrentvalidationandreferencevaluesofgluteusmediusclinicaltest
AT silvapaulal concurrentvalidationandreferencevaluesofgluteusmediusclinicaltest
AT cintrasabrinap concurrentvalidationandreferencevaluesofgluteusmediusclinicaltest
AT viegasfernanda concurrentvalidationandreferencevaluesofgluteusmediusclinicaltest
AT mendoncalucianad concurrentvalidationandreferencevaluesofgluteusmediusclinicaltest
AT bittencourtnataliafn concurrentvalidationandreferencevaluesofgluteusmediusclinicaltest