Cargando…
Concurrent Validation and Reference Values of Gluteus Medius Clinical Test
CONTEXT: The hip abductor muscles, mainly the gluteus medius, are responsible for controlling hip adduction in a closed kinetic chain. Frontal plane knee alignment, assessed during functional activities such squatting, jumping and running, may overload joint structures, like the anterior cruciate li...
Autores principales: | , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
NASMI
2021
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8016418/ https://www.ncbi.nlm.nih.gov/pubmed/33842029 http://dx.doi.org/10.26603/001c.21477 |
_version_ | 1783673856384303104 |
---|---|
author | Teixeira, Amanda S S Silva, Paula L Cintra, Sabrina P Viegas, Fernanda Mendonça, Luciana D Bittencourt, Natália F N |
author_facet | Teixeira, Amanda S S Silva, Paula L Cintra, Sabrina P Viegas, Fernanda Mendonça, Luciana D Bittencourt, Natália F N |
author_sort | Teixeira, Amanda S S |
collection | PubMed |
description | CONTEXT: The hip abductor muscles, mainly the gluteus medius, are responsible for controlling hip adduction in a closed kinetic chain. Frontal plane knee alignment, assessed during functional activities such squatting, jumping and running, may overload joint structures, like the anterior cruciate ligament and patellofemoral joint. The hand-held dynamometer is reliable and effective for testing the muscular strength of the hip abductors. OBJECTIVES: 1. To assess the concurrent validity between the gluteus medius clinical test and a maximum isometric force test of the hip abductors using the hand-held dynamometer; (2) to determine the intra and inter-examiner reliability for the application of the gluteus medius clinical test; and (3) to describe reference values of gluteus medius clinical test on a population of youth athletes. DESIGN: Cross-sectional. METHODS: Thirty healthy individuals were recruited for validity and reliability testing. On the first day, participants performed the maximal isometric test of the hip abductors, measured via hand-held dynamometry. On the following week, the gluteus medius clinical test was performed. Intraclass correlation coefficients (ICC(2,2)) were computed for the reliability analysis, with a 95% confidence interval. To generate reference values, the gluteus medius clinical test was performed on 273 athletes. RESULTS: The results of this study indicated a weak positive correlation (r = 0.436, p = 0.001) between tests, which indicates that they examine different domains of gluteus medius muscle function, likely endurance and muscle strength. The magnitude of computed ICCs (>0.95) indicates excellent intra- and inter-examiner reliability. CONCLUSION: The findings of the current study indicate that the gluteus medius clinical test is reliable and examines a domain of muscular function not fully captured by HHD. The clinical test developed in this study is low-cost and can be included for gluteus medius assessment. LEVEL OF EVIDENCE: Level 3. |
format | Online Article Text |
id | pubmed-8016418 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2021 |
publisher | NASMI |
record_format | MEDLINE/PubMed |
spelling | pubmed-80164182021-04-08 Concurrent Validation and Reference Values of Gluteus Medius Clinical Test Teixeira, Amanda S S Silva, Paula L Cintra, Sabrina P Viegas, Fernanda Mendonça, Luciana D Bittencourt, Natália F N Int J Sports Phys Ther Original Research CONTEXT: The hip abductor muscles, mainly the gluteus medius, are responsible for controlling hip adduction in a closed kinetic chain. Frontal plane knee alignment, assessed during functional activities such squatting, jumping and running, may overload joint structures, like the anterior cruciate ligament and patellofemoral joint. The hand-held dynamometer is reliable and effective for testing the muscular strength of the hip abductors. OBJECTIVES: 1. To assess the concurrent validity between the gluteus medius clinical test and a maximum isometric force test of the hip abductors using the hand-held dynamometer; (2) to determine the intra and inter-examiner reliability for the application of the gluteus medius clinical test; and (3) to describe reference values of gluteus medius clinical test on a population of youth athletes. DESIGN: Cross-sectional. METHODS: Thirty healthy individuals were recruited for validity and reliability testing. On the first day, participants performed the maximal isometric test of the hip abductors, measured via hand-held dynamometry. On the following week, the gluteus medius clinical test was performed. Intraclass correlation coefficients (ICC(2,2)) were computed for the reliability analysis, with a 95% confidence interval. To generate reference values, the gluteus medius clinical test was performed on 273 athletes. RESULTS: The results of this study indicated a weak positive correlation (r = 0.436, p = 0.001) between tests, which indicates that they examine different domains of gluteus medius muscle function, likely endurance and muscle strength. The magnitude of computed ICCs (>0.95) indicates excellent intra- and inter-examiner reliability. CONCLUSION: The findings of the current study indicate that the gluteus medius clinical test is reliable and examines a domain of muscular function not fully captured by HHD. The clinical test developed in this study is low-cost and can be included for gluteus medius assessment. LEVEL OF EVIDENCE: Level 3. NASMI 2021-04-01 /pmc/articles/PMC8016418/ /pubmed/33842029 http://dx.doi.org/10.26603/001c.21477 Text en https://creativecommons.org/licenses/by-nc-sa/4.0/ This is an open access article distributed under the terms of the Creative Commons Attribution-NonCommercial-ShareAlike License (4.0) (https://creativecommons.org/licenses/by-nc-sa/4.0/) which permits non-commercial use, distribution, and reproduction in any medium, provided the original author and source are credited. If you remix, transform, or build upon this work, you must distribute your contributions under the same license as the original. |
spellingShingle | Original Research Teixeira, Amanda S S Silva, Paula L Cintra, Sabrina P Viegas, Fernanda Mendonça, Luciana D Bittencourt, Natália F N Concurrent Validation and Reference Values of Gluteus Medius Clinical Test |
title | Concurrent Validation and Reference Values of Gluteus Medius Clinical Test |
title_full | Concurrent Validation and Reference Values of Gluteus Medius Clinical Test |
title_fullStr | Concurrent Validation and Reference Values of Gluteus Medius Clinical Test |
title_full_unstemmed | Concurrent Validation and Reference Values of Gluteus Medius Clinical Test |
title_short | Concurrent Validation and Reference Values of Gluteus Medius Clinical Test |
title_sort | concurrent validation and reference values of gluteus medius clinical test |
topic | Original Research |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8016418/ https://www.ncbi.nlm.nih.gov/pubmed/33842029 http://dx.doi.org/10.26603/001c.21477 |
work_keys_str_mv | AT teixeiraamandass concurrentvalidationandreferencevaluesofgluteusmediusclinicaltest AT silvapaulal concurrentvalidationandreferencevaluesofgluteusmediusclinicaltest AT cintrasabrinap concurrentvalidationandreferencevaluesofgluteusmediusclinicaltest AT viegasfernanda concurrentvalidationandreferencevaluesofgluteusmediusclinicaltest AT mendoncalucianad concurrentvalidationandreferencevaluesofgluteusmediusclinicaltest AT bittencourtnataliafn concurrentvalidationandreferencevaluesofgluteusmediusclinicaltest |