Cargando…

Clinical outcomes of single implant supported crowns versus 3-unit implant-supported fixed dental prostheses in Dubai Health Authority: a retrospective study

BACKGROUND: This study assessed retrospectively the clinical outcomes of single implant-supported crowns and implant-supported fixed dental prostheses (FDPs). METHODS: This case series compared biological and technical complications in single implant-supported crowns and implant-supported bridges in...

Descripción completa

Detalles Bibliográficos
Autores principales: Alhammadi, Sara Hussain, Burnside, Girvan, Milosevic, Alexander
Formato: Online Artículo Texto
Lenguaje:English
Publicado: BioMed Central 2021
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8017629/
https://www.ncbi.nlm.nih.gov/pubmed/33794841
http://dx.doi.org/10.1186/s12903-021-01530-2
_version_ 1783674087196852224
author Alhammadi, Sara Hussain
Burnside, Girvan
Milosevic, Alexander
author_facet Alhammadi, Sara Hussain
Burnside, Girvan
Milosevic, Alexander
author_sort Alhammadi, Sara Hussain
collection PubMed
description BACKGROUND: This study assessed retrospectively the clinical outcomes of single implant-supported crowns and implant-supported fixed dental prostheses (FDPs). METHODS: This case series compared biological and technical complications in single implant-supported crowns and implant-supported bridges in a time framed sample of all patients who received dental implants between 2009 and 2016 in Dubai Health Authority. Only 3-unit implant-supported prostheses (FDPs) with one intervening pontic and an implant each end were included for comparison to single crown supported implants. Cantilevered implants, implant-supported dentures and cases involving bone grafts or sinus lifts were excluded. The primary outcome measure was marginal bone loss, measured on digital radiographs taken after prosthesis placement at baseline and one year after implant loading, whilst peri-implantitis and technical complications were secondary outcomes. Mixed regression models adjusted for clustering of implants within patients was used for patient and implant factor associations. RESULTS: A total of 454 patients (152 males; 302 females) had 1673 implants. The mean age of males (53.7 years, SD 14.6) was significantly greater than females (49.3 years, SD 12.9, p < 0.001). Mean mesial bone loss on the FDPs was significantly greater at 1 year (1.14 mm, SD 0.63) compared with the mesial surface of single implant-supported crowns (0.30 mm, SD 0.43, p < 0.001). Mean distal bone loss was also significantly greater at 1 year on the distal surfaces of implants supporting bridgework (1.29 mm, SD 0.71) compared with distal surfaces on single implant-supported crowns (0.36 mm, SD 0.54, p < 0.001). Mean marginal bone loss mesially and distally around implants placed in the lower anterior sextant was significantly greater compared to all other sites (p < 0.001). Bone loss by gender, patient’s age and medical condition was not different between the 2 implant groups. Screw loosening was the main technical complication (11.5%) whilst peri-implantitis occurred rarely (0.5%). The 66 cement retained implants had significantly more complications compared to the 1607 screw retained implants (p < 0.001). CONCLUSIONS: Mean marginal bone loss around the supporting implants of FDPs (3-unit fixed bridgework) was greater than on single implant-supported crowns at one year after implant loading. Position in the mouth was associated with bone loss. Biological and technical complications occurred rarely.
format Online
Article
Text
id pubmed-8017629
institution National Center for Biotechnology Information
language English
publishDate 2021
publisher BioMed Central
record_format MEDLINE/PubMed
spelling pubmed-80176292021-04-02 Clinical outcomes of single implant supported crowns versus 3-unit implant-supported fixed dental prostheses in Dubai Health Authority: a retrospective study Alhammadi, Sara Hussain Burnside, Girvan Milosevic, Alexander BMC Oral Health Research Article BACKGROUND: This study assessed retrospectively the clinical outcomes of single implant-supported crowns and implant-supported fixed dental prostheses (FDPs). METHODS: This case series compared biological and technical complications in single implant-supported crowns and implant-supported bridges in a time framed sample of all patients who received dental implants between 2009 and 2016 in Dubai Health Authority. Only 3-unit implant-supported prostheses (FDPs) with one intervening pontic and an implant each end were included for comparison to single crown supported implants. Cantilevered implants, implant-supported dentures and cases involving bone grafts or sinus lifts were excluded. The primary outcome measure was marginal bone loss, measured on digital radiographs taken after prosthesis placement at baseline and one year after implant loading, whilst peri-implantitis and technical complications were secondary outcomes. Mixed regression models adjusted for clustering of implants within patients was used for patient and implant factor associations. RESULTS: A total of 454 patients (152 males; 302 females) had 1673 implants. The mean age of males (53.7 years, SD 14.6) was significantly greater than females (49.3 years, SD 12.9, p < 0.001). Mean mesial bone loss on the FDPs was significantly greater at 1 year (1.14 mm, SD 0.63) compared with the mesial surface of single implant-supported crowns (0.30 mm, SD 0.43, p < 0.001). Mean distal bone loss was also significantly greater at 1 year on the distal surfaces of implants supporting bridgework (1.29 mm, SD 0.71) compared with distal surfaces on single implant-supported crowns (0.36 mm, SD 0.54, p < 0.001). Mean marginal bone loss mesially and distally around implants placed in the lower anterior sextant was significantly greater compared to all other sites (p < 0.001). Bone loss by gender, patient’s age and medical condition was not different between the 2 implant groups. Screw loosening was the main technical complication (11.5%) whilst peri-implantitis occurred rarely (0.5%). The 66 cement retained implants had significantly more complications compared to the 1607 screw retained implants (p < 0.001). CONCLUSIONS: Mean marginal bone loss around the supporting implants of FDPs (3-unit fixed bridgework) was greater than on single implant-supported crowns at one year after implant loading. Position in the mouth was associated with bone loss. Biological and technical complications occurred rarely. BioMed Central 2021-04-01 /pmc/articles/PMC8017629/ /pubmed/33794841 http://dx.doi.org/10.1186/s12903-021-01530-2 Text en © The Author(s) 2021 Open AccessThis article is licensed under a Creative Commons Attribution 4.0 International License, which permits use, sharing, adaptation, distribution and reproduction in any medium or format, as long as you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons licence, and indicate if changes were made. The images or other third party material in this article are included in the article's Creative Commons licence, unless indicated otherwise in a credit line to the material. If material is not included in the article's Creative Commons licence and your intended use is not permitted by statutory regulation or exceeds the permitted use, you will need to obtain permission directly from the copyright holder. To view a copy of this licence, visit http://creativecommons.org/licenses/by/4.0/. The Creative Commons Public Domain Dedication waiver (http://creativecommons.org/publicdomain/zero/1.0/) applies to the data made available in this article, unless otherwise stated in a credit line to the data.
spellingShingle Research Article
Alhammadi, Sara Hussain
Burnside, Girvan
Milosevic, Alexander
Clinical outcomes of single implant supported crowns versus 3-unit implant-supported fixed dental prostheses in Dubai Health Authority: a retrospective study
title Clinical outcomes of single implant supported crowns versus 3-unit implant-supported fixed dental prostheses in Dubai Health Authority: a retrospective study
title_full Clinical outcomes of single implant supported crowns versus 3-unit implant-supported fixed dental prostheses in Dubai Health Authority: a retrospective study
title_fullStr Clinical outcomes of single implant supported crowns versus 3-unit implant-supported fixed dental prostheses in Dubai Health Authority: a retrospective study
title_full_unstemmed Clinical outcomes of single implant supported crowns versus 3-unit implant-supported fixed dental prostheses in Dubai Health Authority: a retrospective study
title_short Clinical outcomes of single implant supported crowns versus 3-unit implant-supported fixed dental prostheses in Dubai Health Authority: a retrospective study
title_sort clinical outcomes of single implant supported crowns versus 3-unit implant-supported fixed dental prostheses in dubai health authority: a retrospective study
topic Research Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8017629/
https://www.ncbi.nlm.nih.gov/pubmed/33794841
http://dx.doi.org/10.1186/s12903-021-01530-2
work_keys_str_mv AT alhammadisarahussain clinicaloutcomesofsingleimplantsupportedcrownsversus3unitimplantsupportedfixeddentalprosthesesindubaihealthauthorityaretrospectivestudy
AT burnsidegirvan clinicaloutcomesofsingleimplantsupportedcrownsversus3unitimplantsupportedfixeddentalprosthesesindubaihealthauthorityaretrospectivestudy
AT milosevicalexander clinicaloutcomesofsingleimplantsupportedcrownsversus3unitimplantsupportedfixeddentalprosthesesindubaihealthauthorityaretrospectivestudy