Cargando…
Complementing Prostate SBRT VMAT With a Two-Beam Non-Coplanar IMRT Class Solution to Enhance Rectum and Bladder Sparing With Minimum Increase in Treatment Time
PURPOSE: Enhance rectum and bladder sparing in prostate SBRT with minimum increase in treatment time by complementing dual-arc coplanar VMAT with a two-beam non-coplanar IMRT class solution (CS). METHODS: For twenty patients, an optimizer for automated multi-criterial planning with integrated beam a...
Autores principales: | , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Frontiers Media S.A.
2021
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8018286/ https://www.ncbi.nlm.nih.gov/pubmed/33816253 http://dx.doi.org/10.3389/fonc.2021.620978 |
_version_ | 1783674185960128512 |
---|---|
author | Sharfo, Abdul Wahab M. Rossi, Linda Dirkx, Maarten L. P. Breedveld, Sebastiaan Aluwini, Shafak Heijmen, Ben J. M. |
author_facet | Sharfo, Abdul Wahab M. Rossi, Linda Dirkx, Maarten L. P. Breedveld, Sebastiaan Aluwini, Shafak Heijmen, Ben J. M. |
author_sort | Sharfo, Abdul Wahab M. |
collection | PubMed |
description | PURPOSE: Enhance rectum and bladder sparing in prostate SBRT with minimum increase in treatment time by complementing dual-arc coplanar VMAT with a two-beam non-coplanar IMRT class solution (CS). METHODS: For twenty patients, an optimizer for automated multi-criterial planning with integrated beam angle optimization (BAO) was used to generate dual-arc VMAT plans, supplemented with five non-coplanar IMRT beams with individually optimized orientations (VMAT+5). In all plan generations, reduction of high rectum dose had the highest priority after obtaining adequate PTV coverage. A CS with two most preferred directions in VMAT+5 and largest rectum dose reductions compared to dual-arc VMAT was then selected to define VMAT+CS. VMAT+CS was compared with automatically generated i) dual-arc coplanar VMAT plans (VMAT), ii) VMAT+5 plans, and iii) IMRT plans with 30 patient-specific non-coplanar beam orientations (30-NCP). Plans were generated for a 4 x 9.5 Gy fractionation scheme. Differences in PTV doses, healthy tissue sparing, and computation and treatment delivery times were quantified. RESULTS: For equal PTV coverage, VMAT+CS, consisting of dual-arc VMAT supplemented with two fixed, non-coplanar IMRT beams with fixed Gantry/Couch angles of 65°/30° and 295°/-30°, significantly reduced OAR doses and the dose bath, compared to dual-arc VMAT. Mean relative differences in rectum D(mean), D(1cc), V(40GyEq) and V(60GyEq) were 19.4 ± 10.6%, 4.2 ± 2.7%, 34.9 ± 20.3%, and 39.7 ± 23.2%, respectively (all p<0.001). There was no difference in bladder D(1cc), while bladder D(mean) reduced by 17.9 ± 11.0% (p<0.001). Also, the clinically evaluated urethra D(5%), D(10%), and D(50%) showed small, but statistically significant improvements. All patient V(X) with X = 2, 5, 10, 20, and 30 Gy were reduced with VMAT+CS, with a maximum relative reduction for V(10Gy) of 19.0 ± 7.3% (p<0.001). Total delivery times with VMAT+CS only increased by 1.9 ± 0.7 min compared to VMAT (9.1 ± 0.7 min). The dosimetric quality of VMAT+CS plans was equivalent to VMAT+5, while optimization times were reduced by a factor of 25 due to avoidance of individualized BAO. Compared to VMAT+CS, the 30-NCP plans were only favorable in terms of dose bath, at the cost of much enhanced optimization and delivery times. CONCLUSIONS: The proposed two-beam non-coplanar class solution to complement coplanar dual-arc VMAT resulted in substantial plan quality improvements for OARs (especially rectum) and reduced irradiated patient volumes with minor increases in treatment delivery times. |
format | Online Article Text |
id | pubmed-8018286 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2021 |
publisher | Frontiers Media S.A. |
record_format | MEDLINE/PubMed |
spelling | pubmed-80182862021-04-03 Complementing Prostate SBRT VMAT With a Two-Beam Non-Coplanar IMRT Class Solution to Enhance Rectum and Bladder Sparing With Minimum Increase in Treatment Time Sharfo, Abdul Wahab M. Rossi, Linda Dirkx, Maarten L. P. Breedveld, Sebastiaan Aluwini, Shafak Heijmen, Ben J. M. Front Oncol Oncology PURPOSE: Enhance rectum and bladder sparing in prostate SBRT with minimum increase in treatment time by complementing dual-arc coplanar VMAT with a two-beam non-coplanar IMRT class solution (CS). METHODS: For twenty patients, an optimizer for automated multi-criterial planning with integrated beam angle optimization (BAO) was used to generate dual-arc VMAT plans, supplemented with five non-coplanar IMRT beams with individually optimized orientations (VMAT+5). In all plan generations, reduction of high rectum dose had the highest priority after obtaining adequate PTV coverage. A CS with two most preferred directions in VMAT+5 and largest rectum dose reductions compared to dual-arc VMAT was then selected to define VMAT+CS. VMAT+CS was compared with automatically generated i) dual-arc coplanar VMAT plans (VMAT), ii) VMAT+5 plans, and iii) IMRT plans with 30 patient-specific non-coplanar beam orientations (30-NCP). Plans were generated for a 4 x 9.5 Gy fractionation scheme. Differences in PTV doses, healthy tissue sparing, and computation and treatment delivery times were quantified. RESULTS: For equal PTV coverage, VMAT+CS, consisting of dual-arc VMAT supplemented with two fixed, non-coplanar IMRT beams with fixed Gantry/Couch angles of 65°/30° and 295°/-30°, significantly reduced OAR doses and the dose bath, compared to dual-arc VMAT. Mean relative differences in rectum D(mean), D(1cc), V(40GyEq) and V(60GyEq) were 19.4 ± 10.6%, 4.2 ± 2.7%, 34.9 ± 20.3%, and 39.7 ± 23.2%, respectively (all p<0.001). There was no difference in bladder D(1cc), while bladder D(mean) reduced by 17.9 ± 11.0% (p<0.001). Also, the clinically evaluated urethra D(5%), D(10%), and D(50%) showed small, but statistically significant improvements. All patient V(X) with X = 2, 5, 10, 20, and 30 Gy were reduced with VMAT+CS, with a maximum relative reduction for V(10Gy) of 19.0 ± 7.3% (p<0.001). Total delivery times with VMAT+CS only increased by 1.9 ± 0.7 min compared to VMAT (9.1 ± 0.7 min). The dosimetric quality of VMAT+CS plans was equivalent to VMAT+5, while optimization times were reduced by a factor of 25 due to avoidance of individualized BAO. Compared to VMAT+CS, the 30-NCP plans were only favorable in terms of dose bath, at the cost of much enhanced optimization and delivery times. CONCLUSIONS: The proposed two-beam non-coplanar class solution to complement coplanar dual-arc VMAT resulted in substantial plan quality improvements for OARs (especially rectum) and reduced irradiated patient volumes with minor increases in treatment delivery times. Frontiers Media S.A. 2021-03-19 /pmc/articles/PMC8018286/ /pubmed/33816253 http://dx.doi.org/10.3389/fonc.2021.620978 Text en Copyright © 2021 Sharfo, Rossi, Dirkx, Breedveld, Aluwini and Heijmen http://creativecommons.org/licenses/by/4.0/ This is an open-access article distributed under the terms of the Creative Commons Attribution License (CC BY). The use, distribution or reproduction in other forums is permitted, provided the original author(s) and the copyright owner(s) are credited and that the original publication in this journal is cited, in accordance with accepted academic practice. No use, distribution or reproduction is permitted which does not comply with these terms. |
spellingShingle | Oncology Sharfo, Abdul Wahab M. Rossi, Linda Dirkx, Maarten L. P. Breedveld, Sebastiaan Aluwini, Shafak Heijmen, Ben J. M. Complementing Prostate SBRT VMAT With a Two-Beam Non-Coplanar IMRT Class Solution to Enhance Rectum and Bladder Sparing With Minimum Increase in Treatment Time |
title | Complementing Prostate SBRT VMAT With a Two-Beam Non-Coplanar IMRT Class Solution to Enhance Rectum and Bladder Sparing With Minimum Increase in Treatment Time |
title_full | Complementing Prostate SBRT VMAT With a Two-Beam Non-Coplanar IMRT Class Solution to Enhance Rectum and Bladder Sparing With Minimum Increase in Treatment Time |
title_fullStr | Complementing Prostate SBRT VMAT With a Two-Beam Non-Coplanar IMRT Class Solution to Enhance Rectum and Bladder Sparing With Minimum Increase in Treatment Time |
title_full_unstemmed | Complementing Prostate SBRT VMAT With a Two-Beam Non-Coplanar IMRT Class Solution to Enhance Rectum and Bladder Sparing With Minimum Increase in Treatment Time |
title_short | Complementing Prostate SBRT VMAT With a Two-Beam Non-Coplanar IMRT Class Solution to Enhance Rectum and Bladder Sparing With Minimum Increase in Treatment Time |
title_sort | complementing prostate sbrt vmat with a two-beam non-coplanar imrt class solution to enhance rectum and bladder sparing with minimum increase in treatment time |
topic | Oncology |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8018286/ https://www.ncbi.nlm.nih.gov/pubmed/33816253 http://dx.doi.org/10.3389/fonc.2021.620978 |
work_keys_str_mv | AT sharfoabdulwahabm complementingprostatesbrtvmatwithatwobeamnoncoplanarimrtclasssolutiontoenhancerectumandbladdersparingwithminimumincreaseintreatmenttime AT rossilinda complementingprostatesbrtvmatwithatwobeamnoncoplanarimrtclasssolutiontoenhancerectumandbladdersparingwithminimumincreaseintreatmenttime AT dirkxmaartenlp complementingprostatesbrtvmatwithatwobeamnoncoplanarimrtclasssolutiontoenhancerectumandbladdersparingwithminimumincreaseintreatmenttime AT breedveldsebastiaan complementingprostatesbrtvmatwithatwobeamnoncoplanarimrtclasssolutiontoenhancerectumandbladdersparingwithminimumincreaseintreatmenttime AT aluwinishafak complementingprostatesbrtvmatwithatwobeamnoncoplanarimrtclasssolutiontoenhancerectumandbladdersparingwithminimumincreaseintreatmenttime AT heijmenbenjm complementingprostatesbrtvmatwithatwobeamnoncoplanarimrtclasssolutiontoenhancerectumandbladdersparingwithminimumincreaseintreatmenttime |