Cargando…
Planning and Design of a Full-Outer-Air-Intake Natural Air-Conditioning System for Medical Negative Pressure Isolation Wards
In the beginning of 2020, the coronavirus (COVID-19) pandemic started to spread globally, causing panic to the lives of people around the world; many countries executed lockdown of cities or even total lockdown of the entire countries. The coronavirus disease (COVID-19) is transmitted via air drople...
Autores principales: | , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Hindawi
2021
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8018840/ https://www.ncbi.nlm.nih.gov/pubmed/33833861 http://dx.doi.org/10.1155/2021/8872167 |
_version_ | 1783674260367081472 |
---|---|
author | Weng, Chien-Lun Kau, Lih-Jen |
author_facet | Weng, Chien-Lun Kau, Lih-Jen |
author_sort | Weng, Chien-Lun |
collection | PubMed |
description | In the beginning of 2020, the coronavirus (COVID-19) pandemic started to spread globally, causing panic to the lives of people around the world; many countries executed lockdown of cities or even total lockdown of the entire countries. The coronavirus disease (COVID-19) is transmitted via air droplets. In medical environments that use traditional hermetic ventilation systems, medical personnel who come in contact with patients are more susceptible to infection compared to regular staff; therefore, the air flow and air quality of hermetic negative pressure isolation wards are highly critical. For this purpose, the study proposes a full-outer-air-intake natural air-conditioning system for negative pressure isolation wards. This innovative system draws in large amounts of fresh external air to greatly improve the air exchange rate in wards; negative pressure environments can be implemented depending on requirements to solve the issue of nosocomial infections in traditional negative pressure isolation wards that draw air from within the hospital. This greatly reduces the probability of nosocomial infection and infection via air droplets; furthermore, the system's intake and exhaust paths are completely isolated, solving the issue of air cross-contamination. Based on the results from the experiment site, this innovative system was designed and implemented based on the guidelines of hospital facilities and achieved air exchange per hour in excess of 12 times/hour, reaching a maximum of 54.5 times/hour. Indoor CO(2) concentration was 576 ppm, negative pressure was −14 Pa, indoor temperature was 23.3°C, indoor humidity was 54.1%, and sensible heat exchange efficiency (ηs) was 105.88% which effectively reduced ventilation load. Therefore, this innovative full-outer-air-intake natural air-conditioning system can provide medical staff and patients with a safe and healthy environment that prevents cross-infection. |
format | Online Article Text |
id | pubmed-8018840 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2021 |
publisher | Hindawi |
record_format | MEDLINE/PubMed |
spelling | pubmed-80188402021-04-07 Planning and Design of a Full-Outer-Air-Intake Natural Air-Conditioning System for Medical Negative Pressure Isolation Wards Weng, Chien-Lun Kau, Lih-Jen J Healthc Eng Research Article In the beginning of 2020, the coronavirus (COVID-19) pandemic started to spread globally, causing panic to the lives of people around the world; many countries executed lockdown of cities or even total lockdown of the entire countries. The coronavirus disease (COVID-19) is transmitted via air droplets. In medical environments that use traditional hermetic ventilation systems, medical personnel who come in contact with patients are more susceptible to infection compared to regular staff; therefore, the air flow and air quality of hermetic negative pressure isolation wards are highly critical. For this purpose, the study proposes a full-outer-air-intake natural air-conditioning system for negative pressure isolation wards. This innovative system draws in large amounts of fresh external air to greatly improve the air exchange rate in wards; negative pressure environments can be implemented depending on requirements to solve the issue of nosocomial infections in traditional negative pressure isolation wards that draw air from within the hospital. This greatly reduces the probability of nosocomial infection and infection via air droplets; furthermore, the system's intake and exhaust paths are completely isolated, solving the issue of air cross-contamination. Based on the results from the experiment site, this innovative system was designed and implemented based on the guidelines of hospital facilities and achieved air exchange per hour in excess of 12 times/hour, reaching a maximum of 54.5 times/hour. Indoor CO(2) concentration was 576 ppm, negative pressure was −14 Pa, indoor temperature was 23.3°C, indoor humidity was 54.1%, and sensible heat exchange efficiency (ηs) was 105.88% which effectively reduced ventilation load. Therefore, this innovative full-outer-air-intake natural air-conditioning system can provide medical staff and patients with a safe and healthy environment that prevents cross-infection. Hindawi 2021-03-25 /pmc/articles/PMC8018840/ /pubmed/33833861 http://dx.doi.org/10.1155/2021/8872167 Text en Copyright © 2021 Chien-Lun Weng and Lih-Jen Kau. https://creativecommons.org/licenses/by/4.0/ This is an open access article distributed under the Creative Commons Attribution License, which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited. |
spellingShingle | Research Article Weng, Chien-Lun Kau, Lih-Jen Planning and Design of a Full-Outer-Air-Intake Natural Air-Conditioning System for Medical Negative Pressure Isolation Wards |
title | Planning and Design of a Full-Outer-Air-Intake Natural Air-Conditioning System for Medical Negative Pressure Isolation Wards |
title_full | Planning and Design of a Full-Outer-Air-Intake Natural Air-Conditioning System for Medical Negative Pressure Isolation Wards |
title_fullStr | Planning and Design of a Full-Outer-Air-Intake Natural Air-Conditioning System for Medical Negative Pressure Isolation Wards |
title_full_unstemmed | Planning and Design of a Full-Outer-Air-Intake Natural Air-Conditioning System for Medical Negative Pressure Isolation Wards |
title_short | Planning and Design of a Full-Outer-Air-Intake Natural Air-Conditioning System for Medical Negative Pressure Isolation Wards |
title_sort | planning and design of a full-outer-air-intake natural air-conditioning system for medical negative pressure isolation wards |
topic | Research Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8018840/ https://www.ncbi.nlm.nih.gov/pubmed/33833861 http://dx.doi.org/10.1155/2021/8872167 |
work_keys_str_mv | AT wengchienlun planninganddesignofafullouterairintakenaturalairconditioningsystemformedicalnegativepressureisolationwards AT kaulihjen planninganddesignofafullouterairintakenaturalairconditioningsystemformedicalnegativepressureisolationwards |