Finite Element Analysis of Femoral Neck Fracture Treated with Bidirectional Compression-Limited Sliding Screw

BACKGROUND: The rate of femoral neck shortening after internal fixation for femoral neck fracture is high and this complication reduces the function of the affected lower limb. The aim of this study was to design a bidirectional compression-limited sliding screw (BCLSC) that can achieve a full balan...

Descripción completa

Detalles Bibliográficos
Autores principales: Huang, Hai, Feng, Zhengkuan, Wang, Weifei, Yang, Cheng, Liao, Jianwen, Ouyang, Jun
Formato: Online Artículo Texto
Lenguaje:English
Publicado: International Scientific Literature, Inc. 2021
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8019266/
https://www.ncbi.nlm.nih.gov/pubmed/33782376
http://dx.doi.org/10.12659/MSM.929163
_version_ 1783674343663861760
author Huang, Hai
Feng, Zhengkuan
Wang, Weifei
Yang, Cheng
Liao, Jianwen
Ouyang, Jun
author_facet Huang, Hai
Feng, Zhengkuan
Wang, Weifei
Yang, Cheng
Liao, Jianwen
Ouyang, Jun
author_sort Huang, Hai
collection PubMed
description BACKGROUND: The rate of femoral neck shortening after internal fixation for femoral neck fracture is high and this complication reduces the function of the affected lower limb. The aim of this study was to design a bidirectional compression-limited sliding screw (BCLSC) that can achieve a full balance between retaining the sliding pressure of the ends of and maintaining the length of the femoral neck. MATERIAL/METHODS: We constructed a 3-dimensional model of a Pauwels III femoral neck fracture and models of 3 internal fixation methods (3 cannulated screws [3CS], dynamic hip screw [DHS]+CS, and BCLSC) by finite element analysis (FEA).The finite element model simulated the loading of the human body when standing on 1 leg. Displacement and stress distribution of the models were calculated based on an axial stress of 600 N. RESULTS: The peak von Mises stress (VMS) values of fracture ends in the 3CS, DHS+CS and BCLSC groups were 94.687 MPa, 26.375 MPa and 45.698 MPa; the peak VMS values of internal fixed stress were 451.53 MPa, 174.45 MPa, and 337.34 MPa; the peak VMS values of the lateral femoral wall were 70.021 MPa, 53.033 MPa, and 20.009 MPa; maximum displacements of the femoral head were 1.4482 mm, 1.3813 mm, and 1.3889 mm; and the internal fixed displacement peaks were 4.1134 mm, 3.91 mm, and 4.1004 mm, respectively. CONCLUSIONS: The FEA showed that compared with the CS, the new BCLSC showed better performance in resisting shearing force for Pauwels III femoral neck fracture, with better mechanical properties. These data provide a basis for further experiments and clinical application.
format Online
Article
Text
id pubmed-8019266
institution National Center for Biotechnology Information
language English
publishDate 2021
publisher International Scientific Literature, Inc.
record_format MEDLINE/PubMed
spelling pubmed-80192662021-04-05 Finite Element Analysis of Femoral Neck Fracture Treated with Bidirectional Compression-Limited Sliding Screw Huang, Hai Feng, Zhengkuan Wang, Weifei Yang, Cheng Liao, Jianwen Ouyang, Jun Med Sci Monit Clinical Research BACKGROUND: The rate of femoral neck shortening after internal fixation for femoral neck fracture is high and this complication reduces the function of the affected lower limb. The aim of this study was to design a bidirectional compression-limited sliding screw (BCLSC) that can achieve a full balance between retaining the sliding pressure of the ends of and maintaining the length of the femoral neck. MATERIAL/METHODS: We constructed a 3-dimensional model of a Pauwels III femoral neck fracture and models of 3 internal fixation methods (3 cannulated screws [3CS], dynamic hip screw [DHS]+CS, and BCLSC) by finite element analysis (FEA).The finite element model simulated the loading of the human body when standing on 1 leg. Displacement and stress distribution of the models were calculated based on an axial stress of 600 N. RESULTS: The peak von Mises stress (VMS) values of fracture ends in the 3CS, DHS+CS and BCLSC groups were 94.687 MPa, 26.375 MPa and 45.698 MPa; the peak VMS values of internal fixed stress were 451.53 MPa, 174.45 MPa, and 337.34 MPa; the peak VMS values of the lateral femoral wall were 70.021 MPa, 53.033 MPa, and 20.009 MPa; maximum displacements of the femoral head were 1.4482 mm, 1.3813 mm, and 1.3889 mm; and the internal fixed displacement peaks were 4.1134 mm, 3.91 mm, and 4.1004 mm, respectively. CONCLUSIONS: The FEA showed that compared with the CS, the new BCLSC showed better performance in resisting shearing force for Pauwels III femoral neck fracture, with better mechanical properties. These data provide a basis for further experiments and clinical application. International Scientific Literature, Inc. 2021-03-30 /pmc/articles/PMC8019266/ /pubmed/33782376 http://dx.doi.org/10.12659/MSM.929163 Text en © Med Sci Monit, 2021 This work is licensed under Creative Common Attribution-NonCommercial-NoDerivatives 4.0 International (CC BY-NC-ND 4.0 (https://creativecommons.org/licenses/by-nc-nd/4.0/) )
spellingShingle Clinical Research
Huang, Hai
Feng, Zhengkuan
Wang, Weifei
Yang, Cheng
Liao, Jianwen
Ouyang, Jun
Finite Element Analysis of Femoral Neck Fracture Treated with Bidirectional Compression-Limited Sliding Screw
title Finite Element Analysis of Femoral Neck Fracture Treated with Bidirectional Compression-Limited Sliding Screw
title_full Finite Element Analysis of Femoral Neck Fracture Treated with Bidirectional Compression-Limited Sliding Screw
title_fullStr Finite Element Analysis of Femoral Neck Fracture Treated with Bidirectional Compression-Limited Sliding Screw
title_full_unstemmed Finite Element Analysis of Femoral Neck Fracture Treated with Bidirectional Compression-Limited Sliding Screw
title_short Finite Element Analysis of Femoral Neck Fracture Treated with Bidirectional Compression-Limited Sliding Screw
title_sort finite element analysis of femoral neck fracture treated with bidirectional compression-limited sliding screw
topic Clinical Research
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8019266/
https://www.ncbi.nlm.nih.gov/pubmed/33782376
http://dx.doi.org/10.12659/MSM.929163
work_keys_str_mv AT huanghai finiteelementanalysisoffemoralneckfracturetreatedwithbidirectionalcompressionlimitedslidingscrew
AT fengzhengkuan finiteelementanalysisoffemoralneckfracturetreatedwithbidirectionalcompressionlimitedslidingscrew
AT wangweifei finiteelementanalysisoffemoralneckfracturetreatedwithbidirectionalcompressionlimitedslidingscrew
AT yangcheng finiteelementanalysisoffemoralneckfracturetreatedwithbidirectionalcompressionlimitedslidingscrew
AT liaojianwen finiteelementanalysisoffemoralneckfracturetreatedwithbidirectionalcompressionlimitedslidingscrew
AT ouyangjun finiteelementanalysisoffemoralneckfracturetreatedwithbidirectionalcompressionlimitedslidingscrew