Cargando…
Comparison of two nucleic acid amplification tests (NAATs) and two antigen tests for detection of SARS-CoV-2 from upper respiratory specimens
There are numerous tests available for acute diagnosis of SARS-CoV-2, the virus that causes the disease COVID-19. These tests fall into two main groups: nucleic acid amplification tests (NAATs) and antigen-based assays. We evaluated the clinical performance of two rapid antigen assays (BD Veritor Sy...
Autores principales: | , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
The Author(s). Published by Elsevier Ltd.
2021
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8019354/ https://www.ncbi.nlm.nih.gov/pubmed/35261999 http://dx.doi.org/10.1016/j.jcvp.2021.100011 |
_version_ | 1783674361753894912 |
---|---|
author | Kuo, Peiting Realegeno, Susan Pride, David T. |
author_facet | Kuo, Peiting Realegeno, Susan Pride, David T. |
author_sort | Kuo, Peiting |
collection | PubMed |
description | There are numerous tests available for acute diagnosis of SARS-CoV-2, the virus that causes the disease COVID-19. These tests fall into two main groups: nucleic acid amplification tests (NAATs) and antigen-based assays. We evaluated the clinical performance of two rapid antigen assays (BD Veritor System for Rapid Detection of SARS CoV-2 and Abbott BinaxNOW COVID-19 Ag Card) and one NAAT (Hologic Aptima SARS CoV-2 Assay) by comparing them with the initial test of record, the Roche cobas SARS-CoV-2 assay; the antigen tests were also compared to Aptima. We tested remnant frozen specimens from patients suspected of SARS-CoV-2 infections (either due to symptoms or exposure) on the comparator platforms to evaluate assay performance across a wide range of positive results, including cobas cycle threshold (Ct) values ranging between 12 and 35. We tested 250 previous positive and 50 previous negative specimens and found 95.6% positive percent agreement (PPA) with the Aptima assay. The few discrepancies between the NAATs occurred only when Ct values were >32. Agreement was much lower for the rapid antigen tests, with 45.2%/47.3% PPA for the Veritor and 47.0%/47.0% PPA for the Binax compared to cobas/Aptima. Discrepancies occurred when cobas Ct values were >20 for Veritor and >25 for Binax. The negative percent agreement (NPA) was 100% for all assay comparisons. These data indicate similar performance between the cobas and Aptima NAATs but demonstrate that antigen-based assays may be insufficient to diagnose SARS-CoV-2 infection when lower levels of the virus are shed. |
format | Online Article Text |
id | pubmed-8019354 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2021 |
publisher | The Author(s). Published by Elsevier Ltd. |
record_format | MEDLINE/PubMed |
spelling | pubmed-80193542021-04-06 Comparison of two nucleic acid amplification tests (NAATs) and two antigen tests for detection of SARS-CoV-2 from upper respiratory specimens Kuo, Peiting Realegeno, Susan Pride, David T. Journal of Clinical Virology Plus Article There are numerous tests available for acute diagnosis of SARS-CoV-2, the virus that causes the disease COVID-19. These tests fall into two main groups: nucleic acid amplification tests (NAATs) and antigen-based assays. We evaluated the clinical performance of two rapid antigen assays (BD Veritor System for Rapid Detection of SARS CoV-2 and Abbott BinaxNOW COVID-19 Ag Card) and one NAAT (Hologic Aptima SARS CoV-2 Assay) by comparing them with the initial test of record, the Roche cobas SARS-CoV-2 assay; the antigen tests were also compared to Aptima. We tested remnant frozen specimens from patients suspected of SARS-CoV-2 infections (either due to symptoms or exposure) on the comparator platforms to evaluate assay performance across a wide range of positive results, including cobas cycle threshold (Ct) values ranging between 12 and 35. We tested 250 previous positive and 50 previous negative specimens and found 95.6% positive percent agreement (PPA) with the Aptima assay. The few discrepancies between the NAATs occurred only when Ct values were >32. Agreement was much lower for the rapid antigen tests, with 45.2%/47.3% PPA for the Veritor and 47.0%/47.0% PPA for the Binax compared to cobas/Aptima. Discrepancies occurred when cobas Ct values were >20 for Veritor and >25 for Binax. The negative percent agreement (NPA) was 100% for all assay comparisons. These data indicate similar performance between the cobas and Aptima NAATs but demonstrate that antigen-based assays may be insufficient to diagnose SARS-CoV-2 infection when lower levels of the virus are shed. The Author(s). Published by Elsevier Ltd. 2021-06 2021-04-03 /pmc/articles/PMC8019354/ /pubmed/35261999 http://dx.doi.org/10.1016/j.jcvp.2021.100011 Text en © 2021 The Author(s). Published by Elsevier Ltd. Since January 2020 Elsevier has created a COVID-19 resource centre with free information in English and Mandarin on the novel coronavirus COVID-19. The COVID-19 resource centre is hosted on Elsevier Connect, the company's public news and information website. Elsevier hereby grants permission to make all its COVID-19-related research that is available on the COVID-19 resource centre - including this research content - immediately available in PubMed Central and other publicly funded repositories, such as the WHO COVID database with rights for unrestricted research re-use and analyses in any form or by any means with acknowledgement of the original source. These permissions are granted for free by Elsevier for as long as the COVID-19 resource centre remains active. |
spellingShingle | Article Kuo, Peiting Realegeno, Susan Pride, David T. Comparison of two nucleic acid amplification tests (NAATs) and two antigen tests for detection of SARS-CoV-2 from upper respiratory specimens |
title | Comparison of two nucleic acid amplification tests (NAATs) and two antigen tests for detection of SARS-CoV-2 from upper respiratory specimens |
title_full | Comparison of two nucleic acid amplification tests (NAATs) and two antigen tests for detection of SARS-CoV-2 from upper respiratory specimens |
title_fullStr | Comparison of two nucleic acid amplification tests (NAATs) and two antigen tests for detection of SARS-CoV-2 from upper respiratory specimens |
title_full_unstemmed | Comparison of two nucleic acid amplification tests (NAATs) and two antigen tests for detection of SARS-CoV-2 from upper respiratory specimens |
title_short | Comparison of two nucleic acid amplification tests (NAATs) and two antigen tests for detection of SARS-CoV-2 from upper respiratory specimens |
title_sort | comparison of two nucleic acid amplification tests (naats) and two antigen tests for detection of sars-cov-2 from upper respiratory specimens |
topic | Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8019354/ https://www.ncbi.nlm.nih.gov/pubmed/35261999 http://dx.doi.org/10.1016/j.jcvp.2021.100011 |
work_keys_str_mv | AT kuopeiting comparisonoftwonucleicacidamplificationtestsnaatsandtwoantigentestsfordetectionofsarscov2fromupperrespiratoryspecimens AT realegenosusan comparisonoftwonucleicacidamplificationtestsnaatsandtwoantigentestsfordetectionofsarscov2fromupperrespiratoryspecimens AT pridedavidt comparisonoftwonucleicacidamplificationtestsnaatsandtwoantigentestsfordetectionofsarscov2fromupperrespiratoryspecimens |