Late Onset Atraumatic Ceramic Head Fracture of a Hybrid Ceramic Bearings Total Hip Arthroplasty
Ceramic head fracture is a major complication of ceramic-on-ceramic (CoC) total hip arthroplasty (THA) and though new generation ceramics have lowered the rates, although it is still a great concern. We report a case of late onset (more than 10 years after surgery) ceramic head fracture of a hybrid...