Cargando…

A randomized controlled trial comparing McGRATH series 5 videolaryngoscope with the Macintosh laryngoscope for nasotracheal intubation

BACKGROUND AND AIMS: The aim of this study was to compare the efficacy of McGRATH series 5 videolaryngoscope (VL) with Macintosh laryngoscope for nasotracheal intubation (NTI) in patients without anticipated difficult airways undergoing head and neck cancer surgeries. MATERIAL AND METHODS: We random...

Descripción completa

Detalles Bibliográficos
Autores principales: Ambulkar, Reshma, Ranganathan, Priya, Savarkar, Sukhada, Divatia, Jigeeshu V.
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Wolters Kluwer - Medknow 2020
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8022068/
https://www.ncbi.nlm.nih.gov/pubmed/33840927
http://dx.doi.org/10.4103/joacp.JOACP_1_20
_version_ 1783674868505509888
author Ambulkar, Reshma
Ranganathan, Priya
Savarkar, Sukhada
Divatia, Jigeeshu V.
author_facet Ambulkar, Reshma
Ranganathan, Priya
Savarkar, Sukhada
Divatia, Jigeeshu V.
author_sort Ambulkar, Reshma
collection PubMed
description BACKGROUND AND AIMS: The aim of this study was to compare the efficacy of McGRATH series 5 videolaryngoscope (VL) with Macintosh laryngoscope for nasotracheal intubation (NTI) in patients without anticipated difficult airways undergoing head and neck cancer surgeries. MATERIAL AND METHODS: We randomized 60 adult patients for NTI by experienced anesthetists with either Macintosh laryngoscope or McGRATH series 5 VL (VL group). The primary objective was to compare time taken for intubation (TTI). The secondary objectives included success rates, number of attempts, need for optimization maneuvers, Cormack and Lehane (CL) grade, and percentage of difficult intubations. RESULTS: The mean TTI in the VL group was 43 (±10.6) versus 75 (±38.0) s in the Macintosh group (99% CI: 12.5; –51.6 s; P < 0.001). The overall intubation success rate was 100% in both groups. All 29 (100%) patients in the VL group were intubated in the first attempt versus 26 (86%) patients in the Macintosh group (99% CI –5; 33%; P = 0.11). In the Macintosh group, 20 (66%) patients needed optimization maneuver versus none in the VL group (99% CI 40; 91%; P < 0.001). In the VL group, 28 (96%) patients had a CL grade 1 view versus 9 (31%) in Macintosh group (99% CI 38; 92%; P < 0.001). There were no difficult intubations in the VL group versus 3 (10%) in the Macintosh group (99% CI: 7; 28%; P = 0.237). There was no trauma to oropharyngeal structures in either group. CONCLUSION: The McGRATH series 5 VL has faster TTI, better glottic visualization, and less need for optimization maneuvers than the Macintosh laryngoscope for NTI in patients with unanticipated difficult airways, when performed by experienced anesthetists.
format Online
Article
Text
id pubmed-8022068
institution National Center for Biotechnology Information
language English
publishDate 2020
publisher Wolters Kluwer - Medknow
record_format MEDLINE/PubMed
spelling pubmed-80220682021-04-08 A randomized controlled trial comparing McGRATH series 5 videolaryngoscope with the Macintosh laryngoscope for nasotracheal intubation Ambulkar, Reshma Ranganathan, Priya Savarkar, Sukhada Divatia, Jigeeshu V. J Anaesthesiol Clin Pharmacol Original Article BACKGROUND AND AIMS: The aim of this study was to compare the efficacy of McGRATH series 5 videolaryngoscope (VL) with Macintosh laryngoscope for nasotracheal intubation (NTI) in patients without anticipated difficult airways undergoing head and neck cancer surgeries. MATERIAL AND METHODS: We randomized 60 adult patients for NTI by experienced anesthetists with either Macintosh laryngoscope or McGRATH series 5 VL (VL group). The primary objective was to compare time taken for intubation (TTI). The secondary objectives included success rates, number of attempts, need for optimization maneuvers, Cormack and Lehane (CL) grade, and percentage of difficult intubations. RESULTS: The mean TTI in the VL group was 43 (±10.6) versus 75 (±38.0) s in the Macintosh group (99% CI: 12.5; –51.6 s; P < 0.001). The overall intubation success rate was 100% in both groups. All 29 (100%) patients in the VL group were intubated in the first attempt versus 26 (86%) patients in the Macintosh group (99% CI –5; 33%; P = 0.11). In the Macintosh group, 20 (66%) patients needed optimization maneuver versus none in the VL group (99% CI 40; 91%; P < 0.001). In the VL group, 28 (96%) patients had a CL grade 1 view versus 9 (31%) in Macintosh group (99% CI 38; 92%; P < 0.001). There were no difficult intubations in the VL group versus 3 (10%) in the Macintosh group (99% CI: 7; 28%; P = 0.237). There was no trauma to oropharyngeal structures in either group. CONCLUSION: The McGRATH series 5 VL has faster TTI, better glottic visualization, and less need for optimization maneuvers than the Macintosh laryngoscope for NTI in patients with unanticipated difficult airways, when performed by experienced anesthetists. Wolters Kluwer - Medknow 2020 2021-01-18 /pmc/articles/PMC8022068/ /pubmed/33840927 http://dx.doi.org/10.4103/joacp.JOACP_1_20 Text en Copyright: © 2021 Journal of Anaesthesiology Clinical Pharmacology http://creativecommons.org/licenses/by-nc-sa/4.0 This is an open access journal, and articles are distributed under the terms of the Creative Commons Attribution-NonCommercial-ShareAlike 4.0 License, which allows others to remix, tweak, and build upon the work non-commercially, as long as appropriate credit is given and the new creations are licensed under the identical terms.
spellingShingle Original Article
Ambulkar, Reshma
Ranganathan, Priya
Savarkar, Sukhada
Divatia, Jigeeshu V.
A randomized controlled trial comparing McGRATH series 5 videolaryngoscope with the Macintosh laryngoscope for nasotracheal intubation
title A randomized controlled trial comparing McGRATH series 5 videolaryngoscope with the Macintosh laryngoscope for nasotracheal intubation
title_full A randomized controlled trial comparing McGRATH series 5 videolaryngoscope with the Macintosh laryngoscope for nasotracheal intubation
title_fullStr A randomized controlled trial comparing McGRATH series 5 videolaryngoscope with the Macintosh laryngoscope for nasotracheal intubation
title_full_unstemmed A randomized controlled trial comparing McGRATH series 5 videolaryngoscope with the Macintosh laryngoscope for nasotracheal intubation
title_short A randomized controlled trial comparing McGRATH series 5 videolaryngoscope with the Macintosh laryngoscope for nasotracheal intubation
title_sort randomized controlled trial comparing mcgrath series 5 videolaryngoscope with the macintosh laryngoscope for nasotracheal intubation
topic Original Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8022068/
https://www.ncbi.nlm.nih.gov/pubmed/33840927
http://dx.doi.org/10.4103/joacp.JOACP_1_20
work_keys_str_mv AT ambulkarreshma arandomizedcontrolledtrialcomparingmcgrathseries5videolaryngoscopewiththemacintoshlaryngoscopefornasotrachealintubation
AT ranganathanpriya arandomizedcontrolledtrialcomparingmcgrathseries5videolaryngoscopewiththemacintoshlaryngoscopefornasotrachealintubation
AT savarkarsukhada arandomizedcontrolledtrialcomparingmcgrathseries5videolaryngoscopewiththemacintoshlaryngoscopefornasotrachealintubation
AT divatiajigeeshuv arandomizedcontrolledtrialcomparingmcgrathseries5videolaryngoscopewiththemacintoshlaryngoscopefornasotrachealintubation
AT ambulkarreshma randomizedcontrolledtrialcomparingmcgrathseries5videolaryngoscopewiththemacintoshlaryngoscopefornasotrachealintubation
AT ranganathanpriya randomizedcontrolledtrialcomparingmcgrathseries5videolaryngoscopewiththemacintoshlaryngoscopefornasotrachealintubation
AT savarkarsukhada randomizedcontrolledtrialcomparingmcgrathseries5videolaryngoscopewiththemacintoshlaryngoscopefornasotrachealintubation
AT divatiajigeeshuv randomizedcontrolledtrialcomparingmcgrathseries5videolaryngoscopewiththemacintoshlaryngoscopefornasotrachealintubation