Increased risk for dislocation after introduction of the Continuum cup system: lessons learnt from a cohort of 1,381 THRs after 1-year follow-up

Background and purpose — The introduction of new total hip replacements (THRs) is known to be associated with an increased risk for complications. On completion of a competitive procurement process, a new uncemented cup system was introduced into general use at our institution in 2016. We launched t...

Descripción completa

Detalles Bibliográficos
Autores principales: Pakarinen, Oskari A, Neuvonen, Perttu S, Reito, Aleksi R P, Eskelinen, Antti P
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Taylor & Francis 2020
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8023946/
https://www.ncbi.nlm.nih.gov/pubmed/32233815
http://dx.doi.org/10.1080/17453674.2020.1744981
_version_ 1783675208741158912
author Pakarinen, Oskari A
Neuvonen, Perttu S
Reito, Aleksi R P
Eskelinen, Antti P
author_facet Pakarinen, Oskari A
Neuvonen, Perttu S
Reito, Aleksi R P
Eskelinen, Antti P
author_sort Pakarinen, Oskari A
collection PubMed
description Background and purpose — The introduction of new total hip replacements (THRs) is known to be associated with an increased risk for complications. On completion of a competitive procurement process, a new uncemented cup system was introduced into general use at our institution in 2016. We launched this study after the introduction to assess (1) the incidence of early dislocations of the old (Pinnacle) and the new (Continuum) cup systems, and (2) whether the cup design would affect the risk for dislocation. Patients and methods — We assessed the incidence of dislocations after 1,381 primary THRs performed at our institution during 2016. Also, the effect of the cup system (Pinnacle, Continuum with neutral liner, Continuum with elevated rim liner) on dislocation rates was analyzed using a multivariable regression model. Results — 47 (3.4%) early dislocations were identified. The incidence of dislocations was 1.3% for the Pinnacle, 5.1% for the Continuum with neutral liner, and 1.2% for the Continuum with elevated rim liner. The Continuum with neutral liner was found to have an increased risk for dislocations compared with the Pinnacle (aOR 5, 95% CI 1.4–17). However, when an elevated rim liner was used with the Continuum, the risk for dislocation between the Continuum and the Pinnacle was similar. Interpretation — Our results emphasize the need for both careful consideration before the introduction of new implants and the systematic monitoring of early outcomes thereafter. The elevated rim liner should be preferred for use with the Continuum cup because of the poor coverage of the neutral liner that may result in dislocations.
format Online
Article
Text
id pubmed-8023946
institution National Center for Biotechnology Information
language English
publishDate 2020
publisher Taylor & Francis
record_format MEDLINE/PubMed
spelling pubmed-80239462021-04-22 Increased risk for dislocation after introduction of the Continuum cup system: lessons learnt from a cohort of 1,381 THRs after 1-year follow-up Pakarinen, Oskari A Neuvonen, Perttu S Reito, Aleksi R P Eskelinen, Antti P Acta Orthop Articles Background and purpose — The introduction of new total hip replacements (THRs) is known to be associated with an increased risk for complications. On completion of a competitive procurement process, a new uncemented cup system was introduced into general use at our institution in 2016. We launched this study after the introduction to assess (1) the incidence of early dislocations of the old (Pinnacle) and the new (Continuum) cup systems, and (2) whether the cup design would affect the risk for dislocation. Patients and methods — We assessed the incidence of dislocations after 1,381 primary THRs performed at our institution during 2016. Also, the effect of the cup system (Pinnacle, Continuum with neutral liner, Continuum with elevated rim liner) on dislocation rates was analyzed using a multivariable regression model. Results — 47 (3.4%) early dislocations were identified. The incidence of dislocations was 1.3% for the Pinnacle, 5.1% for the Continuum with neutral liner, and 1.2% for the Continuum with elevated rim liner. The Continuum with neutral liner was found to have an increased risk for dislocations compared with the Pinnacle (aOR 5, 95% CI 1.4–17). However, when an elevated rim liner was used with the Continuum, the risk for dislocation between the Continuum and the Pinnacle was similar. Interpretation — Our results emphasize the need for both careful consideration before the introduction of new implants and the systematic monitoring of early outcomes thereafter. The elevated rim liner should be preferred for use with the Continuum cup because of the poor coverage of the neutral liner that may result in dislocations. Taylor & Francis 2020-04-01 /pmc/articles/PMC8023946/ /pubmed/32233815 http://dx.doi.org/10.1080/17453674.2020.1744981 Text en © 2020 The Author(s). Published by Taylor & Francis on behalf of the Nordic Orthopedic Federation http://creativecommons.org/licenses/by/4.0/ This is an Open Access article distributed under the terms of the Creative Commons Attribution License (http://creativecommons.org/licenses/by/4.0/), which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited.http://creativecommons.org/licenses/by/4.0/
spellingShingle Articles
Pakarinen, Oskari A
Neuvonen, Perttu S
Reito, Aleksi R P
Eskelinen, Antti P
Increased risk for dislocation after introduction of the Continuum cup system: lessons learnt from a cohort of 1,381 THRs after 1-year follow-up
title Increased risk for dislocation after introduction of the Continuum cup system: lessons learnt from a cohort of 1,381 THRs after 1-year follow-up
title_full Increased risk for dislocation after introduction of the Continuum cup system: lessons learnt from a cohort of 1,381 THRs after 1-year follow-up
title_fullStr Increased risk for dislocation after introduction of the Continuum cup system: lessons learnt from a cohort of 1,381 THRs after 1-year follow-up
title_full_unstemmed Increased risk for dislocation after introduction of the Continuum cup system: lessons learnt from a cohort of 1,381 THRs after 1-year follow-up
title_short Increased risk for dislocation after introduction of the Continuum cup system: lessons learnt from a cohort of 1,381 THRs after 1-year follow-up
title_sort increased risk for dislocation after introduction of the continuum cup system: lessons learnt from a cohort of 1,381 thrs after 1-year follow-up
topic Articles
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8023946/
https://www.ncbi.nlm.nih.gov/pubmed/32233815
http://dx.doi.org/10.1080/17453674.2020.1744981
work_keys_str_mv AT pakarinenoskaria increasedriskfordislocationafterintroductionofthecontinuumcupsystemlessonslearntfromacohortof1381thrsafter1yearfollowup
AT neuvonenperttus increasedriskfordislocationafterintroductionofthecontinuumcupsystemlessonslearntfromacohortof1381thrsafter1yearfollowup
AT reitoaleksirp increasedriskfordislocationafterintroductionofthecontinuumcupsystemlessonslearntfromacohortof1381thrsafter1yearfollowup
AT eskelinenanttip increasedriskfordislocationafterintroductionofthecontinuumcupsystemlessonslearntfromacohortof1381thrsafter1yearfollowup