Cargando…

Simple method for detecting idiopathic interstitial pneumonias by measuring vertical lung length on chest X-ray

Detection of idiopathic interstitial pneumonias (IIPs) on chest X-ray is difficult for non-specialist physicians, especially in patients with mild IIPs. The current study aimed to evaluate the usefulness of a simple method for detecting IIPs by measuring vertical lung length (VLL) in chest X-rays to...

Descripción completa

Detalles Bibliográficos
Autores principales: Karayama, Masato, Aoshima, Yoichiro, Yasui, Hideki, Hozumi, Hironao, Suzuki, Yuzo, Furuhashi, Kazuki, Fujisawa, Tomoyuki, Enomoto, Noriyuki, Nakamura, Yutaro, Inui, Naoki, Suda, Takafumi
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Nature Publishing Group UK 2021
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8027863/
https://www.ncbi.nlm.nih.gov/pubmed/33828219
http://dx.doi.org/10.1038/s41598-021-87452-z
_version_ 1783675880670756864
author Karayama, Masato
Aoshima, Yoichiro
Yasui, Hideki
Hozumi, Hironao
Suzuki, Yuzo
Furuhashi, Kazuki
Fujisawa, Tomoyuki
Enomoto, Noriyuki
Nakamura, Yutaro
Inui, Naoki
Suda, Takafumi
author_facet Karayama, Masato
Aoshima, Yoichiro
Yasui, Hideki
Hozumi, Hironao
Suzuki, Yuzo
Furuhashi, Kazuki
Fujisawa, Tomoyuki
Enomoto, Noriyuki
Nakamura, Yutaro
Inui, Naoki
Suda, Takafumi
author_sort Karayama, Masato
collection PubMed
description Detection of idiopathic interstitial pneumonias (IIPs) on chest X-ray is difficult for non-specialist physicians, especially in patients with mild IIPs. The current study aimed to evaluate the usefulness of a simple method for detecting IIPs by measuring vertical lung length (VLL) in chest X-rays to quantify decreased lung volume. A total of 280 consecutive patients with IIPs were randomly allocated to exploratory and validation cohorts, and 140 controls were selected for each cohort by propensity score-matching. Upper (uVLL; from apex to tracheal carina), lower (lVLL; from carina to costophrenic angle), and total VLL (tVLL; from apex to costophrenic angle), and the l/uVLL ratio were measured on chest X-rays. Patients in the exploratory cohort had significantly decreased uVLL, lVLL, tVLL, and l/uVLL ratio compared with controls (all p < 0.001). Receiver operating characteristic curve analyses demonstrated that lVLL (area under the curve [AUC] 0.86, sensitivity 0.65, specificity 0.92), tVLL (AUC 0.83, sensitivity 0.75, specificity 0.80), and l/uVLL ratio (AUC 0.80, sensitivity 0.72, specificity 0.79) had high diagnostic accuracies for IIPs. These results were reproduced in the validation cohort. IIP patients thus have decreased VLLs, and measurements of VLL may thus aid the accurate detection of IIPs.
format Online
Article
Text
id pubmed-8027863
institution National Center for Biotechnology Information
language English
publishDate 2021
publisher Nature Publishing Group UK
record_format MEDLINE/PubMed
spelling pubmed-80278632021-04-09 Simple method for detecting idiopathic interstitial pneumonias by measuring vertical lung length on chest X-ray Karayama, Masato Aoshima, Yoichiro Yasui, Hideki Hozumi, Hironao Suzuki, Yuzo Furuhashi, Kazuki Fujisawa, Tomoyuki Enomoto, Noriyuki Nakamura, Yutaro Inui, Naoki Suda, Takafumi Sci Rep Article Detection of idiopathic interstitial pneumonias (IIPs) on chest X-ray is difficult for non-specialist physicians, especially in patients with mild IIPs. The current study aimed to evaluate the usefulness of a simple method for detecting IIPs by measuring vertical lung length (VLL) in chest X-rays to quantify decreased lung volume. A total of 280 consecutive patients with IIPs were randomly allocated to exploratory and validation cohorts, and 140 controls were selected for each cohort by propensity score-matching. Upper (uVLL; from apex to tracheal carina), lower (lVLL; from carina to costophrenic angle), and total VLL (tVLL; from apex to costophrenic angle), and the l/uVLL ratio were measured on chest X-rays. Patients in the exploratory cohort had significantly decreased uVLL, lVLL, tVLL, and l/uVLL ratio compared with controls (all p < 0.001). Receiver operating characteristic curve analyses demonstrated that lVLL (area under the curve [AUC] 0.86, sensitivity 0.65, specificity 0.92), tVLL (AUC 0.83, sensitivity 0.75, specificity 0.80), and l/uVLL ratio (AUC 0.80, sensitivity 0.72, specificity 0.79) had high diagnostic accuracies for IIPs. These results were reproduced in the validation cohort. IIP patients thus have decreased VLLs, and measurements of VLL may thus aid the accurate detection of IIPs. Nature Publishing Group UK 2021-04-07 /pmc/articles/PMC8027863/ /pubmed/33828219 http://dx.doi.org/10.1038/s41598-021-87452-z Text en © The Author(s) 2021 Open Access This article is licensed under a Creative Commons Attribution 4.0 International License, which permits use, sharing, adaptation, distribution and reproduction in any medium or format, as long as you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons licence, and indicate if changes were made. The images or other third party material in this article are included in the article's Creative Commons licence, unless indicated otherwise in a credit line to the material. If material is not included in the article's Creative Commons licence and your intended use is not permitted by statutory regulation or exceeds the permitted use, you will need to obtain permission directly from the copyright holder. To view a copy of this licence, visit http://creativecommons.org/licenses/by/4.0/.
spellingShingle Article
Karayama, Masato
Aoshima, Yoichiro
Yasui, Hideki
Hozumi, Hironao
Suzuki, Yuzo
Furuhashi, Kazuki
Fujisawa, Tomoyuki
Enomoto, Noriyuki
Nakamura, Yutaro
Inui, Naoki
Suda, Takafumi
Simple method for detecting idiopathic interstitial pneumonias by measuring vertical lung length on chest X-ray
title Simple method for detecting idiopathic interstitial pneumonias by measuring vertical lung length on chest X-ray
title_full Simple method for detecting idiopathic interstitial pneumonias by measuring vertical lung length on chest X-ray
title_fullStr Simple method for detecting idiopathic interstitial pneumonias by measuring vertical lung length on chest X-ray
title_full_unstemmed Simple method for detecting idiopathic interstitial pneumonias by measuring vertical lung length on chest X-ray
title_short Simple method for detecting idiopathic interstitial pneumonias by measuring vertical lung length on chest X-ray
title_sort simple method for detecting idiopathic interstitial pneumonias by measuring vertical lung length on chest x-ray
topic Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8027863/
https://www.ncbi.nlm.nih.gov/pubmed/33828219
http://dx.doi.org/10.1038/s41598-021-87452-z
work_keys_str_mv AT karayamamasato simplemethodfordetectingidiopathicinterstitialpneumoniasbymeasuringverticallunglengthonchestxray
AT aoshimayoichiro simplemethodfordetectingidiopathicinterstitialpneumoniasbymeasuringverticallunglengthonchestxray
AT yasuihideki simplemethodfordetectingidiopathicinterstitialpneumoniasbymeasuringverticallunglengthonchestxray
AT hozumihironao simplemethodfordetectingidiopathicinterstitialpneumoniasbymeasuringverticallunglengthonchestxray
AT suzukiyuzo simplemethodfordetectingidiopathicinterstitialpneumoniasbymeasuringverticallunglengthonchestxray
AT furuhashikazuki simplemethodfordetectingidiopathicinterstitialpneumoniasbymeasuringverticallunglengthonchestxray
AT fujisawatomoyuki simplemethodfordetectingidiopathicinterstitialpneumoniasbymeasuringverticallunglengthonchestxray
AT enomotonoriyuki simplemethodfordetectingidiopathicinterstitialpneumoniasbymeasuringverticallunglengthonchestxray
AT nakamurayutaro simplemethodfordetectingidiopathicinterstitialpneumoniasbymeasuringverticallunglengthonchestxray
AT inuinaoki simplemethodfordetectingidiopathicinterstitialpneumoniasbymeasuringverticallunglengthonchestxray
AT sudatakafumi simplemethodfordetectingidiopathicinterstitialpneumoniasbymeasuringverticallunglengthonchestxray