Cargando…
Simple method for detecting idiopathic interstitial pneumonias by measuring vertical lung length on chest X-ray
Detection of idiopathic interstitial pneumonias (IIPs) on chest X-ray is difficult for non-specialist physicians, especially in patients with mild IIPs. The current study aimed to evaluate the usefulness of a simple method for detecting IIPs by measuring vertical lung length (VLL) in chest X-rays to...
Autores principales: | , , , , , , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Nature Publishing Group UK
2021
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8027863/ https://www.ncbi.nlm.nih.gov/pubmed/33828219 http://dx.doi.org/10.1038/s41598-021-87452-z |
_version_ | 1783675880670756864 |
---|---|
author | Karayama, Masato Aoshima, Yoichiro Yasui, Hideki Hozumi, Hironao Suzuki, Yuzo Furuhashi, Kazuki Fujisawa, Tomoyuki Enomoto, Noriyuki Nakamura, Yutaro Inui, Naoki Suda, Takafumi |
author_facet | Karayama, Masato Aoshima, Yoichiro Yasui, Hideki Hozumi, Hironao Suzuki, Yuzo Furuhashi, Kazuki Fujisawa, Tomoyuki Enomoto, Noriyuki Nakamura, Yutaro Inui, Naoki Suda, Takafumi |
author_sort | Karayama, Masato |
collection | PubMed |
description | Detection of idiopathic interstitial pneumonias (IIPs) on chest X-ray is difficult for non-specialist physicians, especially in patients with mild IIPs. The current study aimed to evaluate the usefulness of a simple method for detecting IIPs by measuring vertical lung length (VLL) in chest X-rays to quantify decreased lung volume. A total of 280 consecutive patients with IIPs were randomly allocated to exploratory and validation cohorts, and 140 controls were selected for each cohort by propensity score-matching. Upper (uVLL; from apex to tracheal carina), lower (lVLL; from carina to costophrenic angle), and total VLL (tVLL; from apex to costophrenic angle), and the l/uVLL ratio were measured on chest X-rays. Patients in the exploratory cohort had significantly decreased uVLL, lVLL, tVLL, and l/uVLL ratio compared with controls (all p < 0.001). Receiver operating characteristic curve analyses demonstrated that lVLL (area under the curve [AUC] 0.86, sensitivity 0.65, specificity 0.92), tVLL (AUC 0.83, sensitivity 0.75, specificity 0.80), and l/uVLL ratio (AUC 0.80, sensitivity 0.72, specificity 0.79) had high diagnostic accuracies for IIPs. These results were reproduced in the validation cohort. IIP patients thus have decreased VLLs, and measurements of VLL may thus aid the accurate detection of IIPs. |
format | Online Article Text |
id | pubmed-8027863 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2021 |
publisher | Nature Publishing Group UK |
record_format | MEDLINE/PubMed |
spelling | pubmed-80278632021-04-09 Simple method for detecting idiopathic interstitial pneumonias by measuring vertical lung length on chest X-ray Karayama, Masato Aoshima, Yoichiro Yasui, Hideki Hozumi, Hironao Suzuki, Yuzo Furuhashi, Kazuki Fujisawa, Tomoyuki Enomoto, Noriyuki Nakamura, Yutaro Inui, Naoki Suda, Takafumi Sci Rep Article Detection of idiopathic interstitial pneumonias (IIPs) on chest X-ray is difficult for non-specialist physicians, especially in patients with mild IIPs. The current study aimed to evaluate the usefulness of a simple method for detecting IIPs by measuring vertical lung length (VLL) in chest X-rays to quantify decreased lung volume. A total of 280 consecutive patients with IIPs were randomly allocated to exploratory and validation cohorts, and 140 controls were selected for each cohort by propensity score-matching. Upper (uVLL; from apex to tracheal carina), lower (lVLL; from carina to costophrenic angle), and total VLL (tVLL; from apex to costophrenic angle), and the l/uVLL ratio were measured on chest X-rays. Patients in the exploratory cohort had significantly decreased uVLL, lVLL, tVLL, and l/uVLL ratio compared with controls (all p < 0.001). Receiver operating characteristic curve analyses demonstrated that lVLL (area under the curve [AUC] 0.86, sensitivity 0.65, specificity 0.92), tVLL (AUC 0.83, sensitivity 0.75, specificity 0.80), and l/uVLL ratio (AUC 0.80, sensitivity 0.72, specificity 0.79) had high diagnostic accuracies for IIPs. These results were reproduced in the validation cohort. IIP patients thus have decreased VLLs, and measurements of VLL may thus aid the accurate detection of IIPs. Nature Publishing Group UK 2021-04-07 /pmc/articles/PMC8027863/ /pubmed/33828219 http://dx.doi.org/10.1038/s41598-021-87452-z Text en © The Author(s) 2021 Open Access This article is licensed under a Creative Commons Attribution 4.0 International License, which permits use, sharing, adaptation, distribution and reproduction in any medium or format, as long as you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons licence, and indicate if changes were made. The images or other third party material in this article are included in the article's Creative Commons licence, unless indicated otherwise in a credit line to the material. If material is not included in the article's Creative Commons licence and your intended use is not permitted by statutory regulation or exceeds the permitted use, you will need to obtain permission directly from the copyright holder. To view a copy of this licence, visit http://creativecommons.org/licenses/by/4.0/. |
spellingShingle | Article Karayama, Masato Aoshima, Yoichiro Yasui, Hideki Hozumi, Hironao Suzuki, Yuzo Furuhashi, Kazuki Fujisawa, Tomoyuki Enomoto, Noriyuki Nakamura, Yutaro Inui, Naoki Suda, Takafumi Simple method for detecting idiopathic interstitial pneumonias by measuring vertical lung length on chest X-ray |
title | Simple method for detecting idiopathic interstitial pneumonias by measuring vertical lung length on chest X-ray |
title_full | Simple method for detecting idiopathic interstitial pneumonias by measuring vertical lung length on chest X-ray |
title_fullStr | Simple method for detecting idiopathic interstitial pneumonias by measuring vertical lung length on chest X-ray |
title_full_unstemmed | Simple method for detecting idiopathic interstitial pneumonias by measuring vertical lung length on chest X-ray |
title_short | Simple method for detecting idiopathic interstitial pneumonias by measuring vertical lung length on chest X-ray |
title_sort | simple method for detecting idiopathic interstitial pneumonias by measuring vertical lung length on chest x-ray |
topic | Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8027863/ https://www.ncbi.nlm.nih.gov/pubmed/33828219 http://dx.doi.org/10.1038/s41598-021-87452-z |
work_keys_str_mv | AT karayamamasato simplemethodfordetectingidiopathicinterstitialpneumoniasbymeasuringverticallunglengthonchestxray AT aoshimayoichiro simplemethodfordetectingidiopathicinterstitialpneumoniasbymeasuringverticallunglengthonchestxray AT yasuihideki simplemethodfordetectingidiopathicinterstitialpneumoniasbymeasuringverticallunglengthonchestxray AT hozumihironao simplemethodfordetectingidiopathicinterstitialpneumoniasbymeasuringverticallunglengthonchestxray AT suzukiyuzo simplemethodfordetectingidiopathicinterstitialpneumoniasbymeasuringverticallunglengthonchestxray AT furuhashikazuki simplemethodfordetectingidiopathicinterstitialpneumoniasbymeasuringverticallunglengthonchestxray AT fujisawatomoyuki simplemethodfordetectingidiopathicinterstitialpneumoniasbymeasuringverticallunglengthonchestxray AT enomotonoriyuki simplemethodfordetectingidiopathicinterstitialpneumoniasbymeasuringverticallunglengthonchestxray AT nakamurayutaro simplemethodfordetectingidiopathicinterstitialpneumoniasbymeasuringverticallunglengthonchestxray AT inuinaoki simplemethodfordetectingidiopathicinterstitialpneumoniasbymeasuringverticallunglengthonchestxray AT sudatakafumi simplemethodfordetectingidiopathicinterstitialpneumoniasbymeasuringverticallunglengthonchestxray |