Cargando…

Failure of the Interference Tenodesis Screw After Distal Bicep Tendon Repair With a Suture Button Technique: A Report of Two Cases

Distal bicep tendon rupture is an uncommon form of bicep rupture which is typically seen in middle-aged men. We identified two cases in which the distal bicep tendon rupture was repaired with an EndoButton™ (Smith and Nephew, Watford, UK) and interference screw with preservation of the EndoButton™​ ...

Descripción completa

Detalles Bibliográficos
Autores principales: Fletcher, Daniel, Sirch, Francis J, Fletcher, Connor, Beredjiklian, Pedro, Matzon, Jonas
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Cureus 2021
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8029596/
https://www.ncbi.nlm.nih.gov/pubmed/33842155
http://dx.doi.org/10.7759/cureus.13779
_version_ 1783676043769413632
author Fletcher, Daniel
Sirch, Francis J
Fletcher, Connor
Beredjiklian, Pedro
Matzon, Jonas
author_facet Fletcher, Daniel
Sirch, Francis J
Fletcher, Connor
Beredjiklian, Pedro
Matzon, Jonas
author_sort Fletcher, Daniel
collection PubMed
description Distal bicep tendon rupture is an uncommon form of bicep rupture which is typically seen in middle-aged men. We identified two cases in which the distal bicep tendon rupture was repaired with an EndoButton™ (Smith and Nephew, Watford, UK) and interference screw with preservation of the EndoButton™​ but a failure of the interference screw. This report highlights the addition of a FiberWire(®) (Arthrex, Inc., Naples, Florida, USA) construct to secure the interference screw from backing out and emphasizes the EndoButton™ as the primary biomechanical anchor in maintaining a successful distal bicep tendon repair. We question the necessity of both the interference screw and EndoButton™ in the fixation of the distal bicep tendon and recommend that securing the interference tenodesis screw with an additional FiberWire(®) may provide a more secure fixation of the screw as compared to traditional approaches.
format Online
Article
Text
id pubmed-8029596
institution National Center for Biotechnology Information
language English
publishDate 2021
publisher Cureus
record_format MEDLINE/PubMed
spelling pubmed-80295962021-04-09 Failure of the Interference Tenodesis Screw After Distal Bicep Tendon Repair With a Suture Button Technique: A Report of Two Cases Fletcher, Daniel Sirch, Francis J Fletcher, Connor Beredjiklian, Pedro Matzon, Jonas Cureus Orthopedics Distal bicep tendon rupture is an uncommon form of bicep rupture which is typically seen in middle-aged men. We identified two cases in which the distal bicep tendon rupture was repaired with an EndoButton™ (Smith and Nephew, Watford, UK) and interference screw with preservation of the EndoButton™​ but a failure of the interference screw. This report highlights the addition of a FiberWire(®) (Arthrex, Inc., Naples, Florida, USA) construct to secure the interference screw from backing out and emphasizes the EndoButton™ as the primary biomechanical anchor in maintaining a successful distal bicep tendon repair. We question the necessity of both the interference screw and EndoButton™ in the fixation of the distal bicep tendon and recommend that securing the interference tenodesis screw with an additional FiberWire(®) may provide a more secure fixation of the screw as compared to traditional approaches. Cureus 2021-03-09 /pmc/articles/PMC8029596/ /pubmed/33842155 http://dx.doi.org/10.7759/cureus.13779 Text en Copyright © 2021, Fletcher et al. https://creativecommons.org/licenses/by/3.0/This is an open access article distributed under the terms of the Creative Commons Attribution License, which permits unrestricted use, distribution, and reproduction in any medium, provided the original author and source are credited.
spellingShingle Orthopedics
Fletcher, Daniel
Sirch, Francis J
Fletcher, Connor
Beredjiklian, Pedro
Matzon, Jonas
Failure of the Interference Tenodesis Screw After Distal Bicep Tendon Repair With a Suture Button Technique: A Report of Two Cases
title Failure of the Interference Tenodesis Screw After Distal Bicep Tendon Repair With a Suture Button Technique: A Report of Two Cases
title_full Failure of the Interference Tenodesis Screw After Distal Bicep Tendon Repair With a Suture Button Technique: A Report of Two Cases
title_fullStr Failure of the Interference Tenodesis Screw After Distal Bicep Tendon Repair With a Suture Button Technique: A Report of Two Cases
title_full_unstemmed Failure of the Interference Tenodesis Screw After Distal Bicep Tendon Repair With a Suture Button Technique: A Report of Two Cases
title_short Failure of the Interference Tenodesis Screw After Distal Bicep Tendon Repair With a Suture Button Technique: A Report of Two Cases
title_sort failure of the interference tenodesis screw after distal bicep tendon repair with a suture button technique: a report of two cases
topic Orthopedics
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8029596/
https://www.ncbi.nlm.nih.gov/pubmed/33842155
http://dx.doi.org/10.7759/cureus.13779
work_keys_str_mv AT fletcherdaniel failureoftheinterferencetenodesisscrewafterdistalbiceptendonrepairwithasuturebuttontechniqueareportoftwocases
AT sirchfrancisj failureoftheinterferencetenodesisscrewafterdistalbiceptendonrepairwithasuturebuttontechniqueareportoftwocases
AT fletcherconnor failureoftheinterferencetenodesisscrewafterdistalbiceptendonrepairwithasuturebuttontechniqueareportoftwocases
AT beredjiklianpedro failureoftheinterferencetenodesisscrewafterdistalbiceptendonrepairwithasuturebuttontechniqueareportoftwocases
AT matzonjonas failureoftheinterferencetenodesisscrewafterdistalbiceptendonrepairwithasuturebuttontechniqueareportoftwocases