PURPOSE: Swept Source Optical coherence tomography angiography (SS-OCTA) is a novel technique to visualize perfusion and vascular changes like ischemia in patients with diabetic retinopathy. The aim of this study was to compare non-perfusion areas on conventional fluorescein angiography (FA) with th...
Autores principales: | , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Public Library of Science
2021
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8031733/ https://www.ncbi.nlm.nih.gov/pubmed/33831123 http://dx.doi.org/10.1371/journal.pone.0249918 |
_version_ | 1783676176605118464 |
---|---|
author | Podkowinski, Dominika Beka, Sophie Mursch-Edlmayr, Anna-Sophie Strauss, Rupert W. Fischer, Lukas Bolz, Matthias |
author_facet | Podkowinski, Dominika Beka, Sophie Mursch-Edlmayr, Anna-Sophie Strauss, Rupert W. Fischer, Lukas Bolz, Matthias |
author_sort | Podkowinski, Dominika |
collection | PubMed |
description | PURPOSE: Swept Source Optical coherence tomography angiography (SS-OCTA) is a novel technique to visualize perfusion and vascular changes like ischemia in patients with diabetic retinopathy. The aim of this study was to compare non-perfusion areas on conventional fluorescein angiography (FA) with those on SS-OCTA using detailed manual annotation in patients with diabetic macular edema (DME) and to evaluate possible artifacts caused by DME on SS-OCTA. METHODS: 27 eyes of 21 patients with DME were analyzed in this prospective, cross-sectional study; on all, standard ophthalmological examination, SS-OCTA and FA imaging were performed. Early-phase FA and SS-OCTA images were analyzed for capillary dropout and foveal avascular zone (FAZ) was measured on both modalities. Artifacts in SS-OCTA imaging caused by DME were marked and analyzed. RESULTS: The mean age of the patients was 62.6 ± 11.5 years. On FA the mean size of the annotated non-perfusion areas was 0.14 ± 0.31 mm(2) whereas the mean size in SS-OCTA was 0.04 ± 0.13 mm(2); areas marked on FA were statistically significantly larger than on SS-OCTA (p<0.01). Mean size of FAZs was similar between FA and OCTA images. (p = 0.91). Seven eyes (25.9 percent) showed imaging artifacts due to DME in SS-OCTA. CONCLUSION: SS-OCTA is a valid tool to analyze capillary perfusion status of patients with DME, although areas of non-perfusion were measured smaller than in conventional FA. More non-perfusion areas were found on SS-OCTA images. FAZ measurements were similar using the two modalities. However, SS-OCTA is prone to artifacts and therefore requires reviewing of imaging results: up to 25 percent of the analyzed eyes showed artifacts on OCTA, which occurred in the areas of diabetic macular edema and did not correspond to capillary drop out. |
format | Online Article Text |
id | pubmed-8031733 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2021 |
publisher | Public Library of Science |
record_format | MEDLINE/PubMed |
spelling | pubmed-80317332021-04-14 A Swept source optical coherence tomography angiography study: Imaging artifacts and comparison of non-perfusion areas with fluorescein angiography in diabetic macular edema Podkowinski, Dominika Beka, Sophie Mursch-Edlmayr, Anna-Sophie Strauss, Rupert W. Fischer, Lukas Bolz, Matthias PLoS One Research Article PURPOSE: Swept Source Optical coherence tomography angiography (SS-OCTA) is a novel technique to visualize perfusion and vascular changes like ischemia in patients with diabetic retinopathy. The aim of this study was to compare non-perfusion areas on conventional fluorescein angiography (FA) with those on SS-OCTA using detailed manual annotation in patients with diabetic macular edema (DME) and to evaluate possible artifacts caused by DME on SS-OCTA. METHODS: 27 eyes of 21 patients with DME were analyzed in this prospective, cross-sectional study; on all, standard ophthalmological examination, SS-OCTA and FA imaging were performed. Early-phase FA and SS-OCTA images were analyzed for capillary dropout and foveal avascular zone (FAZ) was measured on both modalities. Artifacts in SS-OCTA imaging caused by DME were marked and analyzed. RESULTS: The mean age of the patients was 62.6 ± 11.5 years. On FA the mean size of the annotated non-perfusion areas was 0.14 ± 0.31 mm(2) whereas the mean size in SS-OCTA was 0.04 ± 0.13 mm(2); areas marked on FA were statistically significantly larger than on SS-OCTA (p<0.01). Mean size of FAZs was similar between FA and OCTA images. (p = 0.91). Seven eyes (25.9 percent) showed imaging artifacts due to DME in SS-OCTA. CONCLUSION: SS-OCTA is a valid tool to analyze capillary perfusion status of patients with DME, although areas of non-perfusion were measured smaller than in conventional FA. More non-perfusion areas were found on SS-OCTA images. FAZ measurements were similar using the two modalities. However, SS-OCTA is prone to artifacts and therefore requires reviewing of imaging results: up to 25 percent of the analyzed eyes showed artifacts on OCTA, which occurred in the areas of diabetic macular edema and did not correspond to capillary drop out. Public Library of Science 2021-04-08 /pmc/articles/PMC8031733/ /pubmed/33831123 http://dx.doi.org/10.1371/journal.pone.0249918 Text en © 2021 Podkowinski et al https://creativecommons.org/licenses/by/4.0/This is an open access article distributed under the terms of the Creative Commons Attribution License (https://creativecommons.org/licenses/by/4.0/) , which permits unrestricted use, distribution, and reproduction in any medium, provided the original author and source are credited. |
spellingShingle | Research Article Podkowinski, Dominika Beka, Sophie Mursch-Edlmayr, Anna-Sophie Strauss, Rupert W. Fischer, Lukas Bolz, Matthias A Swept source optical coherence tomography angiography study: Imaging artifacts and comparison of non-perfusion areas with fluorescein angiography in diabetic macular edema |
title | A Swept source optical coherence tomography angiography study: Imaging artifacts and comparison of non-perfusion areas with fluorescein angiography in diabetic macular edema |
title_full | A Swept source optical coherence tomography angiography study: Imaging artifacts and comparison of non-perfusion areas with fluorescein angiography in diabetic macular edema |
title_fullStr | A Swept source optical coherence tomography angiography study: Imaging artifacts and comparison of non-perfusion areas with fluorescein angiography in diabetic macular edema |
title_full_unstemmed | A Swept source optical coherence tomography angiography study: Imaging artifacts and comparison of non-perfusion areas with fluorescein angiography in diabetic macular edema |
title_short | A Swept source optical coherence tomography angiography study: Imaging artifacts and comparison of non-perfusion areas with fluorescein angiography in diabetic macular edema |
title_sort | swept source optical coherence tomography angiography study: imaging artifacts and comparison of non-perfusion areas with fluorescein angiography in diabetic macular edema |
topic | Research Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8031733/ https://www.ncbi.nlm.nih.gov/pubmed/33831123 http://dx.doi.org/10.1371/journal.pone.0249918 |
work_keys_str_mv | AT podkowinskidominika asweptsourceopticalcoherencetomographyangiographystudyimagingartifactsandcomparisonofnonperfusionareaswithfluoresceinangiographyindiabeticmacularedema AT bekasophie asweptsourceopticalcoherencetomographyangiographystudyimagingartifactsandcomparisonofnonperfusionareaswithfluoresceinangiographyindiabeticmacularedema AT murschedlmayrannasophie asweptsourceopticalcoherencetomographyangiographystudyimagingartifactsandcomparisonofnonperfusionareaswithfluoresceinangiographyindiabeticmacularedema AT straussrupertw asweptsourceopticalcoherencetomographyangiographystudyimagingartifactsandcomparisonofnonperfusionareaswithfluoresceinangiographyindiabeticmacularedema AT fischerlukas asweptsourceopticalcoherencetomographyangiographystudyimagingartifactsandcomparisonofnonperfusionareaswithfluoresceinangiographyindiabeticmacularedema AT bolzmatthias asweptsourceopticalcoherencetomographyangiographystudyimagingartifactsandcomparisonofnonperfusionareaswithfluoresceinangiographyindiabeticmacularedema AT podkowinskidominika sweptsourceopticalcoherencetomographyangiographystudyimagingartifactsandcomparisonofnonperfusionareaswithfluoresceinangiographyindiabeticmacularedema AT bekasophie sweptsourceopticalcoherencetomographyangiographystudyimagingartifactsandcomparisonofnonperfusionareaswithfluoresceinangiographyindiabeticmacularedema AT murschedlmayrannasophie sweptsourceopticalcoherencetomographyangiographystudyimagingartifactsandcomparisonofnonperfusionareaswithfluoresceinangiographyindiabeticmacularedema AT straussrupertw sweptsourceopticalcoherencetomographyangiographystudyimagingartifactsandcomparisonofnonperfusionareaswithfluoresceinangiographyindiabeticmacularedema AT fischerlukas sweptsourceopticalcoherencetomographyangiographystudyimagingartifactsandcomparisonofnonperfusionareaswithfluoresceinangiographyindiabeticmacularedema AT bolzmatthias sweptsourceopticalcoherencetomographyangiographystudyimagingartifactsandcomparisonofnonperfusionareaswithfluoresceinangiographyindiabeticmacularedema |