Cargando…
Computational Fluid Dynamics Analysis of Nasal Airway Changes after Treatment with C-Expander
The use of the C-expander is an effective treatment modality for maxillary skeletal deficiencies which can cause ailments and significantly reduce life expectancy in late adolescents and young adults. However, the morphological and dynamic effects on the nasal airway have not been reported. The main...
Autores principales: | , , , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Hindawi
2021
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8032540/ https://www.ncbi.nlm.nih.gov/pubmed/33868456 http://dx.doi.org/10.1155/2021/8874833 |
_version_ | 1783676228808474624 |
---|---|
author | Xiao, Wang Liu, Siling Lu, Yanqin Lei, Lei Liu, Ning Shen, Xiaoping He, Yuhong Liu, Ousheng |
author_facet | Xiao, Wang Liu, Siling Lu, Yanqin Lei, Lei Liu, Ning Shen, Xiaoping He, Yuhong Liu, Ousheng |
author_sort | Xiao, Wang |
collection | PubMed |
description | The use of the C-expander is an effective treatment modality for maxillary skeletal deficiencies which can cause ailments and significantly reduce life expectancy in late adolescents and young adults. However, the morphological and dynamic effects on the nasal airway have not been reported. The main goal of this study was to evaluate the nasal airway changes after the implementation of a C-expander. A sample of nine patients (8 females, 1 male, age range from 15 to 29 years) was included. The morphology parameters and nasal airway ventilation parameters of pretreatment and posttreatment were measured. All study data were normally distributed. A paired t-test was used to evaluate the changes before and after treatment. After expansion, the mean and standard deviation values of intercanine maxillary width (CMW) and intermolar maxillary width (MMW) increased from 35.75 ± 2.48 mm and 54.20 ± 3.17 mm to 37.87 ± 2.26 mm (P < 0.05) and 56.65 ± 3.10 mm (P < 0.05), respectively. The nasal cavity volume increased from 20320.00 ± 3468.25 mm(3) to 23134.70 ± 3918.84 mm(3) (P < 0.05). The nasal pressure drop decreased from 36.34 ± 3.99 Pa to 30.70 ± 3.17 Pa (P < 0.05), while the value of the maximum velocity decreased from 6.50 ± 0.31 m/s to 5.85 ± 0.37 m/s (P < 0.05). Nasal resistance dropped remarkably from 0.16 ± 0.14 Pa/ml/s to 0.08 ± 0.06 Pa/ml/s (P < 0.05). The use of C-expander can effectively broaden the area and volume of the nasal airway, having a positive effect in the reduction of nasal resistance and improvement of nasal airway ventilation. For patients suffering from maxillary width deficiency and respiratory disorders, a C-expander may be an alternative method to treat the disease. |
format | Online Article Text |
id | pubmed-8032540 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2021 |
publisher | Hindawi |
record_format | MEDLINE/PubMed |
spelling | pubmed-80325402021-04-16 Computational Fluid Dynamics Analysis of Nasal Airway Changes after Treatment with C-Expander Xiao, Wang Liu, Siling Lu, Yanqin Lei, Lei Liu, Ning Shen, Xiaoping He, Yuhong Liu, Ousheng Appl Bionics Biomech Research Article The use of the C-expander is an effective treatment modality for maxillary skeletal deficiencies which can cause ailments and significantly reduce life expectancy in late adolescents and young adults. However, the morphological and dynamic effects on the nasal airway have not been reported. The main goal of this study was to evaluate the nasal airway changes after the implementation of a C-expander. A sample of nine patients (8 females, 1 male, age range from 15 to 29 years) was included. The morphology parameters and nasal airway ventilation parameters of pretreatment and posttreatment were measured. All study data were normally distributed. A paired t-test was used to evaluate the changes before and after treatment. After expansion, the mean and standard deviation values of intercanine maxillary width (CMW) and intermolar maxillary width (MMW) increased from 35.75 ± 2.48 mm and 54.20 ± 3.17 mm to 37.87 ± 2.26 mm (P < 0.05) and 56.65 ± 3.10 mm (P < 0.05), respectively. The nasal cavity volume increased from 20320.00 ± 3468.25 mm(3) to 23134.70 ± 3918.84 mm(3) (P < 0.05). The nasal pressure drop decreased from 36.34 ± 3.99 Pa to 30.70 ± 3.17 Pa (P < 0.05), while the value of the maximum velocity decreased from 6.50 ± 0.31 m/s to 5.85 ± 0.37 m/s (P < 0.05). Nasal resistance dropped remarkably from 0.16 ± 0.14 Pa/ml/s to 0.08 ± 0.06 Pa/ml/s (P < 0.05). The use of C-expander can effectively broaden the area and volume of the nasal airway, having a positive effect in the reduction of nasal resistance and improvement of nasal airway ventilation. For patients suffering from maxillary width deficiency and respiratory disorders, a C-expander may be an alternative method to treat the disease. Hindawi 2021-03-31 /pmc/articles/PMC8032540/ /pubmed/33868456 http://dx.doi.org/10.1155/2021/8874833 Text en Copyright © 2021 Wang Xiao et al. https://creativecommons.org/licenses/by/4.0/This is an open access article distributed under the Creative Commons Attribution License, which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited. |
spellingShingle | Research Article Xiao, Wang Liu, Siling Lu, Yanqin Lei, Lei Liu, Ning Shen, Xiaoping He, Yuhong Liu, Ousheng Computational Fluid Dynamics Analysis of Nasal Airway Changes after Treatment with C-Expander |
title | Computational Fluid Dynamics Analysis of Nasal Airway Changes after Treatment with C-Expander |
title_full | Computational Fluid Dynamics Analysis of Nasal Airway Changes after Treatment with C-Expander |
title_fullStr | Computational Fluid Dynamics Analysis of Nasal Airway Changes after Treatment with C-Expander |
title_full_unstemmed | Computational Fluid Dynamics Analysis of Nasal Airway Changes after Treatment with C-Expander |
title_short | Computational Fluid Dynamics Analysis of Nasal Airway Changes after Treatment with C-Expander |
title_sort | computational fluid dynamics analysis of nasal airway changes after treatment with c-expander |
topic | Research Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8032540/ https://www.ncbi.nlm.nih.gov/pubmed/33868456 http://dx.doi.org/10.1155/2021/8874833 |
work_keys_str_mv | AT xiaowang computationalfluiddynamicsanalysisofnasalairwaychangesaftertreatmentwithcexpander AT liusiling computationalfluiddynamicsanalysisofnasalairwaychangesaftertreatmentwithcexpander AT luyanqin computationalfluiddynamicsanalysisofnasalairwaychangesaftertreatmentwithcexpander AT leilei computationalfluiddynamicsanalysisofnasalairwaychangesaftertreatmentwithcexpander AT liuning computationalfluiddynamicsanalysisofnasalairwaychangesaftertreatmentwithcexpander AT shenxiaoping computationalfluiddynamicsanalysisofnasalairwaychangesaftertreatmentwithcexpander AT heyuhong computationalfluiddynamicsanalysisofnasalairwaychangesaftertreatmentwithcexpander AT liuousheng computationalfluiddynamicsanalysisofnasalairwaychangesaftertreatmentwithcexpander |