Cargando…
Thin Strut CoCr Biodegradable Polymer Biolimus A9-Eluting Stents versus Thicker Strut Stainless Steel Biodegradable Polymer Biolimus A9-Eluting Stents: Two-Year Clinical Outcomes
BACKGROUND: While thinner struts are associated with improved clinical outcomes in bare-metal stents (BMS), reducing strut thickness may affect drug delivery from drug-eluting stents (DES) and there are limited data comparing otherwise similar thin and thick strut DES. We assessed 2-year outcomes of...
Autores principales: | , , , , , , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Hindawi
2021
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8032541/ https://www.ncbi.nlm.nih.gov/pubmed/33880087 http://dx.doi.org/10.1155/2021/6654515 |
_version_ | 1783676229033918464 |
---|---|
author | Menown, Ian B. A. Mamas, Mamas A. Cotton, James M. Hildick-Smith, David Eberli, Franz R. Leibundgut, Gregor Tresukosol, Damras Macaya, Carlos Copt, Samuel Slama, Sara Sadozai Oldroyd, Keith G. |
author_facet | Menown, Ian B. A. Mamas, Mamas A. Cotton, James M. Hildick-Smith, David Eberli, Franz R. Leibundgut, Gregor Tresukosol, Damras Macaya, Carlos Copt, Samuel Slama, Sara Sadozai Oldroyd, Keith G. |
author_sort | Menown, Ian B. A. |
collection | PubMed |
description | BACKGROUND: While thinner struts are associated with improved clinical outcomes in bare-metal stents (BMS), reducing strut thickness may affect drug delivery from drug-eluting stents (DES) and there are limited data comparing otherwise similar thin and thick strut DES. We assessed 2-year outcomes of patients treated with a thin strut (84–88um) cobalt-chromium, biodegradable polymer, Biolimus A9-eluting stent (CoCr-BP-BES) and compared these to patients treated with a stainless steel, biodegradable polymer, Biolimus A9-eluting stent (SS-BP-BES). METHODS: In total, 1257 patients were studied: 400 patients from 12 centres receiving ≥1 CoCr-BP-BES in the prospective Biomatrix Alpha registry underwent prespecified comparison with 857 patients who received ≥1 Biomatrix Flex SS-BP-BES in the LEADERS study (historical control). The primary outcome was major adverse cardiac events (MACE)—cardiac death, myocardial infarction (MI), or clinically driven target vessel revascularization (cd-TVR). Propensity analysis was used to adjust for differences in baseline variables and a landmark analysis at day-3 to account for differences in periprocedural MI definitions. RESULTS: MACE at 2 years occurred in 6.65% CoCr-BP-BES versus 13.23% SS-BP-BES groups (unadjusted HR 0.48 [0.31–0.73]; P=0.0005). Following propensity analysis, 2-year adjusted MACE rates were 7.4% versus 13.3% (HR 0.53 [0.35–0.79]; P=0.004). Definite or probable stent thrombosis, adjudicated using identical criteria in both studies, occurred less frequently with CoCr-BP-BES (1.12% vs. 3.22%; adjusted HR 0.32 [0.11–0.9]; P=0.034). In day-3 landmark analysis, the difference in 2-year MACE was no longer significant but there was a lower patient-orientated composite endpoint (11.7% vs. 18.4%; HR 0.6 [0.43–0.83]; P=0.006) and a trend to lower target vessel failure (5.8% vs. 9.1%; HR 0.63 [0.4–1.00]; P=0.078). CONCLUSION: At 2-year follow-up, propensity-adjusted analysis showed the thin strut (84–88um) Biomatrix Alpha CoCr-BP-BES was associated with improved clinical outcomes compared with the thicker strut (114–120um) Biomatrix Flex SS-BP-BES. |
format | Online Article Text |
id | pubmed-8032541 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2021 |
publisher | Hindawi |
record_format | MEDLINE/PubMed |
spelling | pubmed-80325412021-04-19 Thin Strut CoCr Biodegradable Polymer Biolimus A9-Eluting Stents versus Thicker Strut Stainless Steel Biodegradable Polymer Biolimus A9-Eluting Stents: Two-Year Clinical Outcomes Menown, Ian B. A. Mamas, Mamas A. Cotton, James M. Hildick-Smith, David Eberli, Franz R. Leibundgut, Gregor Tresukosol, Damras Macaya, Carlos Copt, Samuel Slama, Sara Sadozai Oldroyd, Keith G. J Interv Cardiol Research Article BACKGROUND: While thinner struts are associated with improved clinical outcomes in bare-metal stents (BMS), reducing strut thickness may affect drug delivery from drug-eluting stents (DES) and there are limited data comparing otherwise similar thin and thick strut DES. We assessed 2-year outcomes of patients treated with a thin strut (84–88um) cobalt-chromium, biodegradable polymer, Biolimus A9-eluting stent (CoCr-BP-BES) and compared these to patients treated with a stainless steel, biodegradable polymer, Biolimus A9-eluting stent (SS-BP-BES). METHODS: In total, 1257 patients were studied: 400 patients from 12 centres receiving ≥1 CoCr-BP-BES in the prospective Biomatrix Alpha registry underwent prespecified comparison with 857 patients who received ≥1 Biomatrix Flex SS-BP-BES in the LEADERS study (historical control). The primary outcome was major adverse cardiac events (MACE)—cardiac death, myocardial infarction (MI), or clinically driven target vessel revascularization (cd-TVR). Propensity analysis was used to adjust for differences in baseline variables and a landmark analysis at day-3 to account for differences in periprocedural MI definitions. RESULTS: MACE at 2 years occurred in 6.65% CoCr-BP-BES versus 13.23% SS-BP-BES groups (unadjusted HR 0.48 [0.31–0.73]; P=0.0005). Following propensity analysis, 2-year adjusted MACE rates were 7.4% versus 13.3% (HR 0.53 [0.35–0.79]; P=0.004). Definite or probable stent thrombosis, adjudicated using identical criteria in both studies, occurred less frequently with CoCr-BP-BES (1.12% vs. 3.22%; adjusted HR 0.32 [0.11–0.9]; P=0.034). In day-3 landmark analysis, the difference in 2-year MACE was no longer significant but there was a lower patient-orientated composite endpoint (11.7% vs. 18.4%; HR 0.6 [0.43–0.83]; P=0.006) and a trend to lower target vessel failure (5.8% vs. 9.1%; HR 0.63 [0.4–1.00]; P=0.078). CONCLUSION: At 2-year follow-up, propensity-adjusted analysis showed the thin strut (84–88um) Biomatrix Alpha CoCr-BP-BES was associated with improved clinical outcomes compared with the thicker strut (114–120um) Biomatrix Flex SS-BP-BES. Hindawi 2021-04-01 /pmc/articles/PMC8032541/ /pubmed/33880087 http://dx.doi.org/10.1155/2021/6654515 Text en Copyright © 2021 Ian B. A. Menown et al. https://creativecommons.org/licenses/by/4.0/This is an open access article distributed under the Creative Commons Attribution License, which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited. |
spellingShingle | Research Article Menown, Ian B. A. Mamas, Mamas A. Cotton, James M. Hildick-Smith, David Eberli, Franz R. Leibundgut, Gregor Tresukosol, Damras Macaya, Carlos Copt, Samuel Slama, Sara Sadozai Oldroyd, Keith G. Thin Strut CoCr Biodegradable Polymer Biolimus A9-Eluting Stents versus Thicker Strut Stainless Steel Biodegradable Polymer Biolimus A9-Eluting Stents: Two-Year Clinical Outcomes |
title | Thin Strut CoCr Biodegradable Polymer Biolimus A9-Eluting Stents versus Thicker Strut Stainless Steel Biodegradable Polymer Biolimus A9-Eluting Stents: Two-Year Clinical Outcomes |
title_full | Thin Strut CoCr Biodegradable Polymer Biolimus A9-Eluting Stents versus Thicker Strut Stainless Steel Biodegradable Polymer Biolimus A9-Eluting Stents: Two-Year Clinical Outcomes |
title_fullStr | Thin Strut CoCr Biodegradable Polymer Biolimus A9-Eluting Stents versus Thicker Strut Stainless Steel Biodegradable Polymer Biolimus A9-Eluting Stents: Two-Year Clinical Outcomes |
title_full_unstemmed | Thin Strut CoCr Biodegradable Polymer Biolimus A9-Eluting Stents versus Thicker Strut Stainless Steel Biodegradable Polymer Biolimus A9-Eluting Stents: Two-Year Clinical Outcomes |
title_short | Thin Strut CoCr Biodegradable Polymer Biolimus A9-Eluting Stents versus Thicker Strut Stainless Steel Biodegradable Polymer Biolimus A9-Eluting Stents: Two-Year Clinical Outcomes |
title_sort | thin strut cocr biodegradable polymer biolimus a9-eluting stents versus thicker strut stainless steel biodegradable polymer biolimus a9-eluting stents: two-year clinical outcomes |
topic | Research Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8032541/ https://www.ncbi.nlm.nih.gov/pubmed/33880087 http://dx.doi.org/10.1155/2021/6654515 |
work_keys_str_mv | AT menownianba thinstrutcocrbiodegradablepolymerbiolimusa9elutingstentsversusthickerstrutstainlesssteelbiodegradablepolymerbiolimusa9elutingstentstwoyearclinicaloutcomes AT mamasmamasa thinstrutcocrbiodegradablepolymerbiolimusa9elutingstentsversusthickerstrutstainlesssteelbiodegradablepolymerbiolimusa9elutingstentstwoyearclinicaloutcomes AT cottonjamesm thinstrutcocrbiodegradablepolymerbiolimusa9elutingstentsversusthickerstrutstainlesssteelbiodegradablepolymerbiolimusa9elutingstentstwoyearclinicaloutcomes AT hildicksmithdavid thinstrutcocrbiodegradablepolymerbiolimusa9elutingstentsversusthickerstrutstainlesssteelbiodegradablepolymerbiolimusa9elutingstentstwoyearclinicaloutcomes AT eberlifranzr thinstrutcocrbiodegradablepolymerbiolimusa9elutingstentsversusthickerstrutstainlesssteelbiodegradablepolymerbiolimusa9elutingstentstwoyearclinicaloutcomes AT leibundgutgregor thinstrutcocrbiodegradablepolymerbiolimusa9elutingstentsversusthickerstrutstainlesssteelbiodegradablepolymerbiolimusa9elutingstentstwoyearclinicaloutcomes AT tresukosoldamras thinstrutcocrbiodegradablepolymerbiolimusa9elutingstentsversusthickerstrutstainlesssteelbiodegradablepolymerbiolimusa9elutingstentstwoyearclinicaloutcomes AT macayacarlos thinstrutcocrbiodegradablepolymerbiolimusa9elutingstentsversusthickerstrutstainlesssteelbiodegradablepolymerbiolimusa9elutingstentstwoyearclinicaloutcomes AT coptsamuel thinstrutcocrbiodegradablepolymerbiolimusa9elutingstentsversusthickerstrutstainlesssteelbiodegradablepolymerbiolimusa9elutingstentstwoyearclinicaloutcomes AT slamasarasadozai thinstrutcocrbiodegradablepolymerbiolimusa9elutingstentsversusthickerstrutstainlesssteelbiodegradablepolymerbiolimusa9elutingstentstwoyearclinicaloutcomes AT oldroydkeithg thinstrutcocrbiodegradablepolymerbiolimusa9elutingstentsversusthickerstrutstainlesssteelbiodegradablepolymerbiolimusa9elutingstentstwoyearclinicaloutcomes |