Cargando…
A novel and efficient surgical knotting technique for high-tension closures
BACKGROUND: The closure of high-tension incisions without any assistance can be difficult and challenging for surgeons. A common practice is to fix the first knot with a clamp and then tie a reverse locking knot; however, this practice has certain disadvantages. The aim of this study was to introduc...
Autores principales: | , , , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
AME Publishing Company
2021
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8033369/ https://www.ncbi.nlm.nih.gov/pubmed/33842596 http://dx.doi.org/10.21037/atm-20-6332 |
_version_ | 1783676399720071168 |
---|---|
author | Chang, Yongyun Yu, Degang Wang, Liao Zhang, Jingwei Yan, Mengning Li, Huiwu Mao, Yuanqing Zhai, Zanjing |
author_facet | Chang, Yongyun Yu, Degang Wang, Liao Zhang, Jingwei Yan, Mengning Li, Huiwu Mao, Yuanqing Zhai, Zanjing |
author_sort | Chang, Yongyun |
collection | PubMed |
description | BACKGROUND: The closure of high-tension incisions without any assistance can be difficult and challenging for surgeons. A common practice is to fix the first knot with a clamp and then tie a reverse locking knot; however, this practice has certain disadvantages. The aim of this study was to introduce a novel and efficient surgical knotting technique with various advantages. METHODS: The two knotting methods used in this study were the absorbable braided suture where the first suture was fixed with a clamp (with assistance) and the SH-9Hospital knotting technique (without assistance) applied on the smooth surface of a cylinder. Mechanical testing was performed using a universal material testing machine. The load-elongation curve and ultimate tensile load (UTL) were recorded. RESULTS: The mean knotting time was 36.40±1.50 s (range, 32–41 s) and 24.80±1.16 s (range, 21–28 s) in the clamp and SH-9Hosptial groups, respectively. The mean UTL was 120.8±10.14 N (range, 81.11–136.55 N)and 126.5±6.29 N (range, 104.88–139.56 N) in the clamp and SH-9Hospital groups, respectively. The knot strength of the SH-9Hospital technique was not inferior to traditional clinical practice. CONCLUSIONS: The SH-9Hospital knotting technique was a secure, convenient, and efficient method for high-tension closure. |
format | Online Article Text |
id | pubmed-8033369 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2021 |
publisher | AME Publishing Company |
record_format | MEDLINE/PubMed |
spelling | pubmed-80333692021-04-09 A novel and efficient surgical knotting technique for high-tension closures Chang, Yongyun Yu, Degang Wang, Liao Zhang, Jingwei Yan, Mengning Li, Huiwu Mao, Yuanqing Zhai, Zanjing Ann Transl Med Original Article BACKGROUND: The closure of high-tension incisions without any assistance can be difficult and challenging for surgeons. A common practice is to fix the first knot with a clamp and then tie a reverse locking knot; however, this practice has certain disadvantages. The aim of this study was to introduce a novel and efficient surgical knotting technique with various advantages. METHODS: The two knotting methods used in this study were the absorbable braided suture where the first suture was fixed with a clamp (with assistance) and the SH-9Hospital knotting technique (without assistance) applied on the smooth surface of a cylinder. Mechanical testing was performed using a universal material testing machine. The load-elongation curve and ultimate tensile load (UTL) were recorded. RESULTS: The mean knotting time was 36.40±1.50 s (range, 32–41 s) and 24.80±1.16 s (range, 21–28 s) in the clamp and SH-9Hosptial groups, respectively. The mean UTL was 120.8±10.14 N (range, 81.11–136.55 N)and 126.5±6.29 N (range, 104.88–139.56 N) in the clamp and SH-9Hospital groups, respectively. The knot strength of the SH-9Hospital technique was not inferior to traditional clinical practice. CONCLUSIONS: The SH-9Hospital knotting technique was a secure, convenient, and efficient method for high-tension closure. AME Publishing Company 2021-03 /pmc/articles/PMC8033369/ /pubmed/33842596 http://dx.doi.org/10.21037/atm-20-6332 Text en 2021 Annals of Translational Medicine. All rights reserved. https://creativecommons.org/licenses/by-nc-nd/4.0/Open Access Statement: This is an Open Access article distributed in accordance with the Creative Commons Attribution-NonCommercial-NoDerivs 4.0 International License (CC BY-NC-ND 4.0), which permits the non-commercial replication and distribution of the article with the strict proviso that no changes or edits are made and the original work is properly cited (including links to both the formal publication through the relevant DOI and the license). See: https://creativecommons.org/licenses/by-nc-nd/4.0 (https://creativecommons.org/licenses/by-nc-nd/4.0/) . |
spellingShingle | Original Article Chang, Yongyun Yu, Degang Wang, Liao Zhang, Jingwei Yan, Mengning Li, Huiwu Mao, Yuanqing Zhai, Zanjing A novel and efficient surgical knotting technique for high-tension closures |
title | A novel and efficient surgical knotting technique for high-tension closures |
title_full | A novel and efficient surgical knotting technique for high-tension closures |
title_fullStr | A novel and efficient surgical knotting technique for high-tension closures |
title_full_unstemmed | A novel and efficient surgical knotting technique for high-tension closures |
title_short | A novel and efficient surgical knotting technique for high-tension closures |
title_sort | novel and efficient surgical knotting technique for high-tension closures |
topic | Original Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8033369/ https://www.ncbi.nlm.nih.gov/pubmed/33842596 http://dx.doi.org/10.21037/atm-20-6332 |
work_keys_str_mv | AT changyongyun anovelandefficientsurgicalknottingtechniqueforhightensionclosures AT yudegang anovelandefficientsurgicalknottingtechniqueforhightensionclosures AT wangliao anovelandefficientsurgicalknottingtechniqueforhightensionclosures AT zhangjingwei anovelandefficientsurgicalknottingtechniqueforhightensionclosures AT yanmengning anovelandefficientsurgicalknottingtechniqueforhightensionclosures AT lihuiwu anovelandefficientsurgicalknottingtechniqueforhightensionclosures AT maoyuanqing anovelandefficientsurgicalknottingtechniqueforhightensionclosures AT zhaizanjing anovelandefficientsurgicalknottingtechniqueforhightensionclosures AT changyongyun novelandefficientsurgicalknottingtechniqueforhightensionclosures AT yudegang novelandefficientsurgicalknottingtechniqueforhightensionclosures AT wangliao novelandefficientsurgicalknottingtechniqueforhightensionclosures AT zhangjingwei novelandefficientsurgicalknottingtechniqueforhightensionclosures AT yanmengning novelandefficientsurgicalknottingtechniqueforhightensionclosures AT lihuiwu novelandefficientsurgicalknottingtechniqueforhightensionclosures AT maoyuanqing novelandefficientsurgicalknottingtechniqueforhightensionclosures AT zhaizanjing novelandefficientsurgicalknottingtechniqueforhightensionclosures |