Cargando…

A novel and efficient surgical knotting technique for high-tension closures

BACKGROUND: The closure of high-tension incisions without any assistance can be difficult and challenging for surgeons. A common practice is to fix the first knot with a clamp and then tie a reverse locking knot; however, this practice has certain disadvantages. The aim of this study was to introduc...

Descripción completa

Detalles Bibliográficos
Autores principales: Chang, Yongyun, Yu, Degang, Wang, Liao, Zhang, Jingwei, Yan, Mengning, Li, Huiwu, Mao, Yuanqing, Zhai, Zanjing
Formato: Online Artículo Texto
Lenguaje:English
Publicado: AME Publishing Company 2021
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8033369/
https://www.ncbi.nlm.nih.gov/pubmed/33842596
http://dx.doi.org/10.21037/atm-20-6332
_version_ 1783676399720071168
author Chang, Yongyun
Yu, Degang
Wang, Liao
Zhang, Jingwei
Yan, Mengning
Li, Huiwu
Mao, Yuanqing
Zhai, Zanjing
author_facet Chang, Yongyun
Yu, Degang
Wang, Liao
Zhang, Jingwei
Yan, Mengning
Li, Huiwu
Mao, Yuanqing
Zhai, Zanjing
author_sort Chang, Yongyun
collection PubMed
description BACKGROUND: The closure of high-tension incisions without any assistance can be difficult and challenging for surgeons. A common practice is to fix the first knot with a clamp and then tie a reverse locking knot; however, this practice has certain disadvantages. The aim of this study was to introduce a novel and efficient surgical knotting technique with various advantages. METHODS: The two knotting methods used in this study were the absorbable braided suture where the first suture was fixed with a clamp (with assistance) and the SH-9Hospital knotting technique (without assistance) applied on the smooth surface of a cylinder. Mechanical testing was performed using a universal material testing machine. The load-elongation curve and ultimate tensile load (UTL) were recorded. RESULTS: The mean knotting time was 36.40±1.50 s (range, 32–41 s) and 24.80±1.16 s (range, 21–28 s) in the clamp and SH-9Hosptial groups, respectively. The mean UTL was 120.8±10.14 N (range, 81.11–136.55 N)and 126.5±6.29 N (range, 104.88–139.56 N) in the clamp and SH-9Hospital groups, respectively. The knot strength of the SH-9Hospital technique was not inferior to traditional clinical practice. CONCLUSIONS: The SH-9Hospital knotting technique was a secure, convenient, and efficient method for high-tension closure.
format Online
Article
Text
id pubmed-8033369
institution National Center for Biotechnology Information
language English
publishDate 2021
publisher AME Publishing Company
record_format MEDLINE/PubMed
spelling pubmed-80333692021-04-09 A novel and efficient surgical knotting technique for high-tension closures Chang, Yongyun Yu, Degang Wang, Liao Zhang, Jingwei Yan, Mengning Li, Huiwu Mao, Yuanqing Zhai, Zanjing Ann Transl Med Original Article BACKGROUND: The closure of high-tension incisions without any assistance can be difficult and challenging for surgeons. A common practice is to fix the first knot with a clamp and then tie a reverse locking knot; however, this practice has certain disadvantages. The aim of this study was to introduce a novel and efficient surgical knotting technique with various advantages. METHODS: The two knotting methods used in this study were the absorbable braided suture where the first suture was fixed with a clamp (with assistance) and the SH-9Hospital knotting technique (without assistance) applied on the smooth surface of a cylinder. Mechanical testing was performed using a universal material testing machine. The load-elongation curve and ultimate tensile load (UTL) were recorded. RESULTS: The mean knotting time was 36.40±1.50 s (range, 32–41 s) and 24.80±1.16 s (range, 21–28 s) in the clamp and SH-9Hosptial groups, respectively. The mean UTL was 120.8±10.14 N (range, 81.11–136.55 N)and 126.5±6.29 N (range, 104.88–139.56 N) in the clamp and SH-9Hospital groups, respectively. The knot strength of the SH-9Hospital technique was not inferior to traditional clinical practice. CONCLUSIONS: The SH-9Hospital knotting technique was a secure, convenient, and efficient method for high-tension closure. AME Publishing Company 2021-03 /pmc/articles/PMC8033369/ /pubmed/33842596 http://dx.doi.org/10.21037/atm-20-6332 Text en 2021 Annals of Translational Medicine. All rights reserved. https://creativecommons.org/licenses/by-nc-nd/4.0/Open Access Statement: This is an Open Access article distributed in accordance with the Creative Commons Attribution-NonCommercial-NoDerivs 4.0 International License (CC BY-NC-ND 4.0), which permits the non-commercial replication and distribution of the article with the strict proviso that no changes or edits are made and the original work is properly cited (including links to both the formal publication through the relevant DOI and the license). See: https://creativecommons.org/licenses/by-nc-nd/4.0 (https://creativecommons.org/licenses/by-nc-nd/4.0/) .
spellingShingle Original Article
Chang, Yongyun
Yu, Degang
Wang, Liao
Zhang, Jingwei
Yan, Mengning
Li, Huiwu
Mao, Yuanqing
Zhai, Zanjing
A novel and efficient surgical knotting technique for high-tension closures
title A novel and efficient surgical knotting technique for high-tension closures
title_full A novel and efficient surgical knotting technique for high-tension closures
title_fullStr A novel and efficient surgical knotting technique for high-tension closures
title_full_unstemmed A novel and efficient surgical knotting technique for high-tension closures
title_short A novel and efficient surgical knotting technique for high-tension closures
title_sort novel and efficient surgical knotting technique for high-tension closures
topic Original Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8033369/
https://www.ncbi.nlm.nih.gov/pubmed/33842596
http://dx.doi.org/10.21037/atm-20-6332
work_keys_str_mv AT changyongyun anovelandefficientsurgicalknottingtechniqueforhightensionclosures
AT yudegang anovelandefficientsurgicalknottingtechniqueforhightensionclosures
AT wangliao anovelandefficientsurgicalknottingtechniqueforhightensionclosures
AT zhangjingwei anovelandefficientsurgicalknottingtechniqueforhightensionclosures
AT yanmengning anovelandefficientsurgicalknottingtechniqueforhightensionclosures
AT lihuiwu anovelandefficientsurgicalknottingtechniqueforhightensionclosures
AT maoyuanqing anovelandefficientsurgicalknottingtechniqueforhightensionclosures
AT zhaizanjing anovelandefficientsurgicalknottingtechniqueforhightensionclosures
AT changyongyun novelandefficientsurgicalknottingtechniqueforhightensionclosures
AT yudegang novelandefficientsurgicalknottingtechniqueforhightensionclosures
AT wangliao novelandefficientsurgicalknottingtechniqueforhightensionclosures
AT zhangjingwei novelandefficientsurgicalknottingtechniqueforhightensionclosures
AT yanmengning novelandefficientsurgicalknottingtechniqueforhightensionclosures
AT lihuiwu novelandefficientsurgicalknottingtechniqueforhightensionclosures
AT maoyuanqing novelandefficientsurgicalknottingtechniqueforhightensionclosures
AT zhaizanjing novelandefficientsurgicalknottingtechniqueforhightensionclosures