Comparison of VerifyNow, thromboelastography, and PL-12 in patients with minor ischemic stroke or transient ischemic attack

High on-treatment platelet reactivity (HOPR) is associated with stroke recurrence. It is important to find a reliable method to assess HOPR. We aimed to compare the correlations between VerifyNow™ system, thromboelastography (TEG), and Aggrestar platelet function analyzer (PL-12) on platelet activit...

Descripción completa

Detalles Bibliográficos
Autores principales: Ma, Lin, Chen, Weiqi, Pan, Yuesong, Yan, Hongyi, Li, Hao, Meng, Xia, Wang, Yongjun, Wang, Yilong
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Impact Journals 2021
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8034945/
https://www.ncbi.nlm.nih.gov/pubmed/33686963
http://dx.doi.org/10.18632/aging.202650
_version_ 1783676625631576064
author Ma, Lin
Chen, Weiqi
Pan, Yuesong
Yan, Hongyi
Li, Hao
Meng, Xia
Wang, Yongjun
Wang, Yilong
author_facet Ma, Lin
Chen, Weiqi
Pan, Yuesong
Yan, Hongyi
Li, Hao
Meng, Xia
Wang, Yongjun
Wang, Yilong
author_sort Ma, Lin
collection PubMed
description High on-treatment platelet reactivity (HOPR) is associated with stroke recurrence. It is important to find a reliable method to assess HOPR. We aimed to compare the correlations between VerifyNow™ system, thromboelastography (TEG), and Aggrestar platelet function analyzer (PL-12) on platelet activity in patients with minor ischemic stroke or transient ischemic attack (TIA) after dual antiplatelet therapy for 7 days. About 276 patients were included. Spearman’s correlation coefficient and the kappa coefficient were adopted to evaluate associations among the three test methods. An obvious correlation between VerifyNow and TEG on HOPR-ADP (r=0.64, p<0.001) was found. The correlations of HOPR-ADP between PL-12 and the other two platelet function analyzers were moderate (PL-12 versus VerifyNow, r=0.47, p<0.001; PL-12 versus TEG, r=0.25, p<0.001). The correlations of HOPR-AA were limited among these three platelet function analyzers (VerifyNow versus TEG, r=0.09, p=0.14; VerifyNow versus PL-12, r=0.15, p=0.01; PL-12 versus TEG, r=0.10, p=0.09). Correlations among different platelet function analyzers were varied. VerifyNow and TEG were more correlative than PL-12 on HOPR-ADP. The consistence of HOPR-AA was limited among VerifyNow, TEG and PL-12. The proportion of stroke recurrence and composite events in patients with HOPR-ADP assessing by PL-12 was higher than VerifyNow and TEG.
format Online
Article
Text
id pubmed-8034945
institution National Center for Biotechnology Information
language English
publishDate 2021
publisher Impact Journals
record_format MEDLINE/PubMed
spelling pubmed-80349452021-04-16 Comparison of VerifyNow, thromboelastography, and PL-12 in patients with minor ischemic stroke or transient ischemic attack Ma, Lin Chen, Weiqi Pan, Yuesong Yan, Hongyi Li, Hao Meng, Xia Wang, Yongjun Wang, Yilong Aging (Albany NY) Research Paper High on-treatment platelet reactivity (HOPR) is associated with stroke recurrence. It is important to find a reliable method to assess HOPR. We aimed to compare the correlations between VerifyNow™ system, thromboelastography (TEG), and Aggrestar platelet function analyzer (PL-12) on platelet activity in patients with minor ischemic stroke or transient ischemic attack (TIA) after dual antiplatelet therapy for 7 days. About 276 patients were included. Spearman’s correlation coefficient and the kappa coefficient were adopted to evaluate associations among the three test methods. An obvious correlation between VerifyNow and TEG on HOPR-ADP (r=0.64, p<0.001) was found. The correlations of HOPR-ADP between PL-12 and the other two platelet function analyzers were moderate (PL-12 versus VerifyNow, r=0.47, p<0.001; PL-12 versus TEG, r=0.25, p<0.001). The correlations of HOPR-AA were limited among these three platelet function analyzers (VerifyNow versus TEG, r=0.09, p=0.14; VerifyNow versus PL-12, r=0.15, p=0.01; PL-12 versus TEG, r=0.10, p=0.09). Correlations among different platelet function analyzers were varied. VerifyNow and TEG were more correlative than PL-12 on HOPR-ADP. The consistence of HOPR-AA was limited among VerifyNow, TEG and PL-12. The proportion of stroke recurrence and composite events in patients with HOPR-ADP assessing by PL-12 was higher than VerifyNow and TEG. Impact Journals 2021-03-03 /pmc/articles/PMC8034945/ /pubmed/33686963 http://dx.doi.org/10.18632/aging.202650 Text en Copyright: © 2021 Ma et al. https://creativecommons.org/licenses/by/3.0/This is an open access article distributed under the terms of the Creative Commons Attribution License (https://creativecommons.org/licenses/by/3.0/) (CC BY 3.0), which permits unrestricted use, distribution, and reproduction in any medium, provided the original author and source are credited.
spellingShingle Research Paper
Ma, Lin
Chen, Weiqi
Pan, Yuesong
Yan, Hongyi
Li, Hao
Meng, Xia
Wang, Yongjun
Wang, Yilong
Comparison of VerifyNow, thromboelastography, and PL-12 in patients with minor ischemic stroke or transient ischemic attack
title Comparison of VerifyNow, thromboelastography, and PL-12 in patients with minor ischemic stroke or transient ischemic attack
title_full Comparison of VerifyNow, thromboelastography, and PL-12 in patients with minor ischemic stroke or transient ischemic attack
title_fullStr Comparison of VerifyNow, thromboelastography, and PL-12 in patients with minor ischemic stroke or transient ischemic attack
title_full_unstemmed Comparison of VerifyNow, thromboelastography, and PL-12 in patients with minor ischemic stroke or transient ischemic attack
title_short Comparison of VerifyNow, thromboelastography, and PL-12 in patients with minor ischemic stroke or transient ischemic attack
title_sort comparison of verifynow, thromboelastography, and pl-12 in patients with minor ischemic stroke or transient ischemic attack
topic Research Paper
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8034945/
https://www.ncbi.nlm.nih.gov/pubmed/33686963
http://dx.doi.org/10.18632/aging.202650
work_keys_str_mv AT malin comparisonofverifynowthromboelastographyandpl12inpatientswithminorischemicstrokeortransientischemicattack
AT chenweiqi comparisonofverifynowthromboelastographyandpl12inpatientswithminorischemicstrokeortransientischemicattack
AT panyuesong comparisonofverifynowthromboelastographyandpl12inpatientswithminorischemicstrokeortransientischemicattack
AT yanhongyi comparisonofverifynowthromboelastographyandpl12inpatientswithminorischemicstrokeortransientischemicattack
AT lihao comparisonofverifynowthromboelastographyandpl12inpatientswithminorischemicstrokeortransientischemicattack
AT mengxia comparisonofverifynowthromboelastographyandpl12inpatientswithminorischemicstrokeortransientischemicattack
AT wangyongjun comparisonofverifynowthromboelastographyandpl12inpatientswithminorischemicstrokeortransientischemicattack
AT wangyilong comparisonofverifynowthromboelastographyandpl12inpatientswithminorischemicstrokeortransientischemicattack