Analysis of prostate intensity‐ and volumetric‐modulated arc radiation therapy planning quality with PlanIQ(TM)
PURPOSE: The purpose of this study was to assess the quality of treatment planning using the PlanIQ(TM) software and to investigate whether it is possible to improve the quality of treatment planning using the “Feasibility dose‐volume histogram (DVH)(TM)” implemented in the PlanIQ(TM) software. METH...
Autores principales: | , , , , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
John Wiley and Sons Inc.
2021
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8035557/ https://www.ncbi.nlm.nih.gov/pubmed/33768648 http://dx.doi.org/10.1002/acm2.13233 |
_version_ | 1783676724300480512 |
---|---|
author | Sasaki, Motoharu Nakaguuchi, Yuji Kamomae, Takeshi Tsuzuki, Akira Kobuchi, Satoshi Kuwahara, Kenmei Ueda, Shoji Endo, Yuto Ikushima, Hitoshi |
author_facet | Sasaki, Motoharu Nakaguuchi, Yuji Kamomae, Takeshi Tsuzuki, Akira Kobuchi, Satoshi Kuwahara, Kenmei Ueda, Shoji Endo, Yuto Ikushima, Hitoshi |
author_sort | Sasaki, Motoharu |
collection | PubMed |
description | PURPOSE: The purpose of this study was to assess the quality of treatment planning using the PlanIQ(TM) software and to investigate whether it is possible to improve the quality of treatment planning using the “Feasibility dose‐volume histogram (DVH)(TM)” implemented in the PlanIQ(TM) software. METHODS: Using the PlanIQ(TM) software, we retrospectively analyzed the learning curve regarding the quality of the treatment plans for 148 patients of prostate intensity‐modulated radiation therapy and volumetric‐modulated radiation therapy performed at our institution over the past eight years. We also sought to examine the possibility of improving treatment planning quality by re‐planning in 47 patients where the quality of the target dose and the dose limits for organs at risk (OARs) were inadequate. The re‐planning treatment plans referred to the Feasibility DVH(TM) implemented in the PlanIQ(TM) software and modified the treatment planning system based on the target dose and OAR constraints. RESULTS: Analysis of the learning curve of the treatment plans quality using PlanIQ(TM) software retrospectively showed a trend of improvement in the treatment plan quality from year to year. The improvement in the treatment plans quality was more influenced by dose reduction in the OARs than by target coverage. In all cases where re‐planning was performed, the improvement in the treatment plan's quality resulted in a better treatment plan than the one adopted for delivery to patients in the clinical plan. CONCLUSIONS: The PlanIQ(TM) provided insights into the quality of the treatment plans at our institution and identified problems and areas for improvement in the treatment plans, allowing for the development of appropriate treatment plans for specific patients. |
format | Online Article Text |
id | pubmed-8035557 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2021 |
publisher | John Wiley and Sons Inc. |
record_format | MEDLINE/PubMed |
spelling | pubmed-80355572021-04-15 Analysis of prostate intensity‐ and volumetric‐modulated arc radiation therapy planning quality with PlanIQ(TM) Sasaki, Motoharu Nakaguuchi, Yuji Kamomae, Takeshi Tsuzuki, Akira Kobuchi, Satoshi Kuwahara, Kenmei Ueda, Shoji Endo, Yuto Ikushima, Hitoshi J Appl Clin Med Phys Radiation Oncology Physics PURPOSE: The purpose of this study was to assess the quality of treatment planning using the PlanIQ(TM) software and to investigate whether it is possible to improve the quality of treatment planning using the “Feasibility dose‐volume histogram (DVH)(TM)” implemented in the PlanIQ(TM) software. METHODS: Using the PlanIQ(TM) software, we retrospectively analyzed the learning curve regarding the quality of the treatment plans for 148 patients of prostate intensity‐modulated radiation therapy and volumetric‐modulated radiation therapy performed at our institution over the past eight years. We also sought to examine the possibility of improving treatment planning quality by re‐planning in 47 patients where the quality of the target dose and the dose limits for organs at risk (OARs) were inadequate. The re‐planning treatment plans referred to the Feasibility DVH(TM) implemented in the PlanIQ(TM) software and modified the treatment planning system based on the target dose and OAR constraints. RESULTS: Analysis of the learning curve of the treatment plans quality using PlanIQ(TM) software retrospectively showed a trend of improvement in the treatment plan quality from year to year. The improvement in the treatment plans quality was more influenced by dose reduction in the OARs than by target coverage. In all cases where re‐planning was performed, the improvement in the treatment plan's quality resulted in a better treatment plan than the one adopted for delivery to patients in the clinical plan. CONCLUSIONS: The PlanIQ(TM) provided insights into the quality of the treatment plans at our institution and identified problems and areas for improvement in the treatment plans, allowing for the development of appropriate treatment plans for specific patients. John Wiley and Sons Inc. 2021-03-25 /pmc/articles/PMC8035557/ /pubmed/33768648 http://dx.doi.org/10.1002/acm2.13233 Text en © 2021 The Authors. Journal of Applied Clinical Medical Physics published by Wiley Periodicals LLC on behalf of American Association of Physicists in Medicine https://creativecommons.org/licenses/by/4.0/This is an open access article under the terms of the http://creativecommons.org/licenses/by/4.0/ (https://creativecommons.org/licenses/by/4.0/) License, which permits use, distribution and reproduction in any medium, provided the original work is properly cited. |
spellingShingle | Radiation Oncology Physics Sasaki, Motoharu Nakaguuchi, Yuji Kamomae, Takeshi Tsuzuki, Akira Kobuchi, Satoshi Kuwahara, Kenmei Ueda, Shoji Endo, Yuto Ikushima, Hitoshi Analysis of prostate intensity‐ and volumetric‐modulated arc radiation therapy planning quality with PlanIQ(TM) |
title | Analysis of prostate intensity‐ and volumetric‐modulated arc radiation therapy planning quality with PlanIQ(TM)
|
title_full | Analysis of prostate intensity‐ and volumetric‐modulated arc radiation therapy planning quality with PlanIQ(TM)
|
title_fullStr | Analysis of prostate intensity‐ and volumetric‐modulated arc radiation therapy planning quality with PlanIQ(TM)
|
title_full_unstemmed | Analysis of prostate intensity‐ and volumetric‐modulated arc radiation therapy planning quality with PlanIQ(TM)
|
title_short | Analysis of prostate intensity‐ and volumetric‐modulated arc radiation therapy planning quality with PlanIQ(TM)
|
title_sort | analysis of prostate intensity‐ and volumetric‐modulated arc radiation therapy planning quality with planiq(tm) |
topic | Radiation Oncology Physics |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8035557/ https://www.ncbi.nlm.nih.gov/pubmed/33768648 http://dx.doi.org/10.1002/acm2.13233 |
work_keys_str_mv | AT sasakimotoharu analysisofprostateintensityandvolumetricmodulatedarcradiationtherapyplanningqualitywithplaniqtm AT nakaguuchiyuji analysisofprostateintensityandvolumetricmodulatedarcradiationtherapyplanningqualitywithplaniqtm AT kamomaetakeshi analysisofprostateintensityandvolumetricmodulatedarcradiationtherapyplanningqualitywithplaniqtm AT tsuzukiakira analysisofprostateintensityandvolumetricmodulatedarcradiationtherapyplanningqualitywithplaniqtm AT kobuchisatoshi analysisofprostateintensityandvolumetricmodulatedarcradiationtherapyplanningqualitywithplaniqtm AT kuwaharakenmei analysisofprostateintensityandvolumetricmodulatedarcradiationtherapyplanningqualitywithplaniqtm AT uedashoji analysisofprostateintensityandvolumetricmodulatedarcradiationtherapyplanningqualitywithplaniqtm AT endoyuto analysisofprostateintensityandvolumetricmodulatedarcradiationtherapyplanningqualitywithplaniqtm AT ikushimahitoshi analysisofprostateintensityandvolumetricmodulatedarcradiationtherapyplanningqualitywithplaniqtm |