Cargando…
Effectiveness and reliability of cannulated fenestrated screws augmented with polymethylmethacrylate cement in the surgical treatment of osteoporotic vertebral fractures
BACKGROUND: Implants' stability, especially in osteoporosis patients, is a challenging matter. Nowadays, the adoption of cannulated fenestrated screws augmented with polymethylmethacrylate cement (PMMA CSF) is described by some authors. This single-center, retrospective observational study aims...
Autores principales: | , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Wolters Kluwer - Medknow
2021
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8035586/ https://www.ncbi.nlm.nih.gov/pubmed/33850379 http://dx.doi.org/10.4103/jcvjs.JCVJS_188_20 |
_version_ | 1783676730337132544 |
---|---|
author | Coniglio, Angela Rava, Alessandro Fusini, Federico Colò, Gabriele Massè, Alessandro Girardo, Massimo |
author_facet | Coniglio, Angela Rava, Alessandro Fusini, Federico Colò, Gabriele Massè, Alessandro Girardo, Massimo |
author_sort | Coniglio, Angela |
collection | PubMed |
description | BACKGROUND: Implants' stability, especially in osteoporosis patients, is a challenging matter. Nowadays, the adoption of cannulated fenestrated screws augmented with polymethylmethacrylate cement (PMMA CSF) is described by some authors. This single-center, retrospective observational study aims to evaluate the long-term effectiveness, reliability, and mechanical performances of this type of screws in osteoporotic fractures. MATERIALS AND METHODS: All the patients surgically treated from January 2009 to December 2019 with PMMA CSF were evaluated and submitted to the inclusion and exclusion criteria. Clinical and radiological evaluations were performed at pre- and post-surgery time and at the follow-up (FU). Loss of correction in the sagittal plane (bisegmental Cobb angle), kyphosis angle of the fracture (fractured vertebral angle), loosening of pedicle screws (screw's apex vertebral body's anterior cortex mean gap called SAAC gap and screw's apex vertebral body's superior endplate mean gap called SASE gap), visual analog scale, and Oswestry disability index scores were evaluated. RESULTS: One hundred and sixty-three patients (58 males and 105 females) aged over 65 years affected by vertebral osteoporotic fractures were included in the study. At FU, we do not found significant differences in radiological items in respect to the postoperative period. Only one case of loosening and 18 cases of cement leaking (without neurological impairments) were found. Clinical scores improvement was significant in the interval between preoperative and FU. CONCLUSIONS: PMMA CSF seems to can guarantee good efficacy and effectiveness in the surgical treatment of vertebral fractures in osteoporosis. |
format | Online Article Text |
id | pubmed-8035586 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2021 |
publisher | Wolters Kluwer - Medknow |
record_format | MEDLINE/PubMed |
spelling | pubmed-80355862021-04-12 Effectiveness and reliability of cannulated fenestrated screws augmented with polymethylmethacrylate cement in the surgical treatment of osteoporotic vertebral fractures Coniglio, Angela Rava, Alessandro Fusini, Federico Colò, Gabriele Massè, Alessandro Girardo, Massimo J Craniovertebr Junction Spine Original Article BACKGROUND: Implants' stability, especially in osteoporosis patients, is a challenging matter. Nowadays, the adoption of cannulated fenestrated screws augmented with polymethylmethacrylate cement (PMMA CSF) is described by some authors. This single-center, retrospective observational study aims to evaluate the long-term effectiveness, reliability, and mechanical performances of this type of screws in osteoporotic fractures. MATERIALS AND METHODS: All the patients surgically treated from January 2009 to December 2019 with PMMA CSF were evaluated and submitted to the inclusion and exclusion criteria. Clinical and radiological evaluations were performed at pre- and post-surgery time and at the follow-up (FU). Loss of correction in the sagittal plane (bisegmental Cobb angle), kyphosis angle of the fracture (fractured vertebral angle), loosening of pedicle screws (screw's apex vertebral body's anterior cortex mean gap called SAAC gap and screw's apex vertebral body's superior endplate mean gap called SASE gap), visual analog scale, and Oswestry disability index scores were evaluated. RESULTS: One hundred and sixty-three patients (58 males and 105 females) aged over 65 years affected by vertebral osteoporotic fractures were included in the study. At FU, we do not found significant differences in radiological items in respect to the postoperative period. Only one case of loosening and 18 cases of cement leaking (without neurological impairments) were found. Clinical scores improvement was significant in the interval between preoperative and FU. CONCLUSIONS: PMMA CSF seems to can guarantee good efficacy and effectiveness in the surgical treatment of vertebral fractures in osteoporosis. Wolters Kluwer - Medknow 2021 2021-03-04 /pmc/articles/PMC8035586/ /pubmed/33850379 http://dx.doi.org/10.4103/jcvjs.JCVJS_188_20 Text en Copyright: © 2021 Journal of Craniovertebral Junction and Spine https://creativecommons.org/licenses/by-nc-sa/4.0/This is an open access journal, and articles are distributed under the terms of the Creative Commons Attribution-NonCommercial-ShareAlike 4.0 License, which allows others to remix, tweak, and build upon the work non-commercially, as long as appropriate credit is given and the new creations are licensed under the identical terms. |
spellingShingle | Original Article Coniglio, Angela Rava, Alessandro Fusini, Federico Colò, Gabriele Massè, Alessandro Girardo, Massimo Effectiveness and reliability of cannulated fenestrated screws augmented with polymethylmethacrylate cement in the surgical treatment of osteoporotic vertebral fractures |
title | Effectiveness and reliability of cannulated fenestrated screws augmented with polymethylmethacrylate cement in the surgical treatment of osteoporotic vertebral fractures |
title_full | Effectiveness and reliability of cannulated fenestrated screws augmented with polymethylmethacrylate cement in the surgical treatment of osteoporotic vertebral fractures |
title_fullStr | Effectiveness and reliability of cannulated fenestrated screws augmented with polymethylmethacrylate cement in the surgical treatment of osteoporotic vertebral fractures |
title_full_unstemmed | Effectiveness and reliability of cannulated fenestrated screws augmented with polymethylmethacrylate cement in the surgical treatment of osteoporotic vertebral fractures |
title_short | Effectiveness and reliability of cannulated fenestrated screws augmented with polymethylmethacrylate cement in the surgical treatment of osteoporotic vertebral fractures |
title_sort | effectiveness and reliability of cannulated fenestrated screws augmented with polymethylmethacrylate cement in the surgical treatment of osteoporotic vertebral fractures |
topic | Original Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8035586/ https://www.ncbi.nlm.nih.gov/pubmed/33850379 http://dx.doi.org/10.4103/jcvjs.JCVJS_188_20 |
work_keys_str_mv | AT coniglioangela effectivenessandreliabilityofcannulatedfenestratedscrewsaugmentedwithpolymethylmethacrylatecementinthesurgicaltreatmentofosteoporoticvertebralfractures AT ravaalessandro effectivenessandreliabilityofcannulatedfenestratedscrewsaugmentedwithpolymethylmethacrylatecementinthesurgicaltreatmentofosteoporoticvertebralfractures AT fusinifederico effectivenessandreliabilityofcannulatedfenestratedscrewsaugmentedwithpolymethylmethacrylatecementinthesurgicaltreatmentofosteoporoticvertebralfractures AT cologabriele effectivenessandreliabilityofcannulatedfenestratedscrewsaugmentedwithpolymethylmethacrylatecementinthesurgicaltreatmentofosteoporoticvertebralfractures AT massealessandro effectivenessandreliabilityofcannulatedfenestratedscrewsaugmentedwithpolymethylmethacrylatecementinthesurgicaltreatmentofosteoporoticvertebralfractures AT girardomassimo effectivenessandreliabilityofcannulatedfenestratedscrewsaugmentedwithpolymethylmethacrylatecementinthesurgicaltreatmentofosteoporoticvertebralfractures |