Cargando…
The Correlation between Head of Bed Angle and Intra-Abdominal Pressure of Intubated Patients; a Pre-Post Clinical Trial
INTRODUCTION: The recommended position for measuring Intra-Abdominal Pressure (IAP) is the supine position. However, patients put in this position are prone to Ventilator-associated pneumonia. This study was done to evaluate the relationship between bed head angle and IAP measurements of intubated p...
Autores principales: | , , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Shahid Beheshti University of Medical Sciences
2021
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8035694/ https://www.ncbi.nlm.nih.gov/pubmed/33870210 http://dx.doi.org/10.22037/aaem.v9i1.1065 |
_version_ | 1783676754784681984 |
---|---|
author | Samimian, Sedigheh Ashrafi, Sadra Khaleghdoost Mohammadi, Tahereh Yeganeh, Mohammad Reza Ashraf, Ali Hakimi, Hamideh Dehghani, Maryam |
author_facet | Samimian, Sedigheh Ashrafi, Sadra Khaleghdoost Mohammadi, Tahereh Yeganeh, Mohammad Reza Ashraf, Ali Hakimi, Hamideh Dehghani, Maryam |
author_sort | Samimian, Sedigheh |
collection | PubMed |
description | INTRODUCTION: The recommended position for measuring Intra-Abdominal Pressure (IAP) is the supine position. However, patients put in this position are prone to Ventilator-associated pneumonia. This study was done to evaluate the relationship between bed head angle and IAP measurements of intubated patients in the intensive care unit. METHODS: In this clinical trial, seventy-six critically ill patients under mechanical ventilation were enrolled. IAP measurement was performed every 8 hours for 24 hours using the KORN method in three different degrees of the head of bed (HOB) elevation (0 [Formula: see text] , 15 [Formula: see text] , and 30 [Formula: see text]). Bland-Altman analysis was performed to identify the bias and limits of agreement among the three HOBs. According to World Society of the Abdominal Compartment Syndrome (WSACS), we can consider two IAP techniques equivalent if a bias of <1 mmHg and limits of agreement of - 4 to +4 were found between them. Data were analyzed using SPSS statistical software (v. 19), and the significance level was considered as 0.05. RESULTS: The prevalence of intra-abdominal hypertension was 18.42%. Mean ± standard deviation (SD) of IAP were 8.44 ± 4.02 mmHg for HOB angle 0°, 9.58 ± 4.52 for HOB angle 15 [Formula: see text] and 11.10 ± 4.73 for HOB angle 30(o) (p = 0.0001). The IAP measurement bias between HOB angle 0°and HOB angle 15° was 1.13 mmHg. This bias was 2.66 mmHg between HOB angle 0° and HOB angle 30°. CONCLUSION: Elevation of HOB angle from 0 to 30 degree significantly increases IAP. It seems that the measurement of IAP at HOB angle 15° was more reliable than 30°. |
format | Online Article Text |
id | pubmed-8035694 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2021 |
publisher | Shahid Beheshti University of Medical Sciences |
record_format | MEDLINE/PubMed |
spelling | pubmed-80356942021-04-16 The Correlation between Head of Bed Angle and Intra-Abdominal Pressure of Intubated Patients; a Pre-Post Clinical Trial Samimian, Sedigheh Ashrafi, Sadra Khaleghdoost Mohammadi, Tahereh Yeganeh, Mohammad Reza Ashraf, Ali Hakimi, Hamideh Dehghani, Maryam Arch Acad Emerg Med Original Research INTRODUCTION: The recommended position for measuring Intra-Abdominal Pressure (IAP) is the supine position. However, patients put in this position are prone to Ventilator-associated pneumonia. This study was done to evaluate the relationship between bed head angle and IAP measurements of intubated patients in the intensive care unit. METHODS: In this clinical trial, seventy-six critically ill patients under mechanical ventilation were enrolled. IAP measurement was performed every 8 hours for 24 hours using the KORN method in three different degrees of the head of bed (HOB) elevation (0 [Formula: see text] , 15 [Formula: see text] , and 30 [Formula: see text]). Bland-Altman analysis was performed to identify the bias and limits of agreement among the three HOBs. According to World Society of the Abdominal Compartment Syndrome (WSACS), we can consider two IAP techniques equivalent if a bias of <1 mmHg and limits of agreement of - 4 to +4 were found between them. Data were analyzed using SPSS statistical software (v. 19), and the significance level was considered as 0.05. RESULTS: The prevalence of intra-abdominal hypertension was 18.42%. Mean ± standard deviation (SD) of IAP were 8.44 ± 4.02 mmHg for HOB angle 0°, 9.58 ± 4.52 for HOB angle 15 [Formula: see text] and 11.10 ± 4.73 for HOB angle 30(o) (p = 0.0001). The IAP measurement bias between HOB angle 0°and HOB angle 15° was 1.13 mmHg. This bias was 2.66 mmHg between HOB angle 0° and HOB angle 30°. CONCLUSION: Elevation of HOB angle from 0 to 30 degree significantly increases IAP. It seems that the measurement of IAP at HOB angle 15° was more reliable than 30°. Shahid Beheshti University of Medical Sciences 2021-03-06 /pmc/articles/PMC8035694/ /pubmed/33870210 http://dx.doi.org/10.22037/aaem.v9i1.1065 Text en https://creativecommons.org/licenses/by/3.0/This is an Open Access article distributed under the terms of the Creative Commons Attribution License, (http://creativecommons.org/licenses/by/3.0/ (https://creativecommons.org/licenses/by/3.0/) ) which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited. |
spellingShingle | Original Research Samimian, Sedigheh Ashrafi, Sadra Khaleghdoost Mohammadi, Tahereh Yeganeh, Mohammad Reza Ashraf, Ali Hakimi, Hamideh Dehghani, Maryam The Correlation between Head of Bed Angle and Intra-Abdominal Pressure of Intubated Patients; a Pre-Post Clinical Trial |
title | The Correlation between Head of Bed Angle and Intra-Abdominal Pressure of Intubated Patients; a Pre-Post Clinical Trial |
title_full | The Correlation between Head of Bed Angle and Intra-Abdominal Pressure of Intubated Patients; a Pre-Post Clinical Trial |
title_fullStr | The Correlation between Head of Bed Angle and Intra-Abdominal Pressure of Intubated Patients; a Pre-Post Clinical Trial |
title_full_unstemmed | The Correlation between Head of Bed Angle and Intra-Abdominal Pressure of Intubated Patients; a Pre-Post Clinical Trial |
title_short | The Correlation between Head of Bed Angle and Intra-Abdominal Pressure of Intubated Patients; a Pre-Post Clinical Trial |
title_sort | correlation between head of bed angle and intra-abdominal pressure of intubated patients; a pre-post clinical trial |
topic | Original Research |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8035694/ https://www.ncbi.nlm.nih.gov/pubmed/33870210 http://dx.doi.org/10.22037/aaem.v9i1.1065 |
work_keys_str_mv | AT samimiansedigheh thecorrelationbetweenheadofbedangleandintraabdominalpressureofintubatedpatientsaprepostclinicaltrial AT ashrafisadra thecorrelationbetweenheadofbedangleandintraabdominalpressureofintubatedpatientsaprepostclinicaltrial AT khaleghdoostmohammaditahereh thecorrelationbetweenheadofbedangleandintraabdominalpressureofintubatedpatientsaprepostclinicaltrial AT yeganehmohammadreza thecorrelationbetweenheadofbedangleandintraabdominalpressureofintubatedpatientsaprepostclinicaltrial AT ashrafali thecorrelationbetweenheadofbedangleandintraabdominalpressureofintubatedpatientsaprepostclinicaltrial AT hakimihamideh thecorrelationbetweenheadofbedangleandintraabdominalpressureofintubatedpatientsaprepostclinicaltrial AT dehghanimaryam thecorrelationbetweenheadofbedangleandintraabdominalpressureofintubatedpatientsaprepostclinicaltrial AT samimiansedigheh correlationbetweenheadofbedangleandintraabdominalpressureofintubatedpatientsaprepostclinicaltrial AT ashrafisadra correlationbetweenheadofbedangleandintraabdominalpressureofintubatedpatientsaprepostclinicaltrial AT khaleghdoostmohammaditahereh correlationbetweenheadofbedangleandintraabdominalpressureofintubatedpatientsaprepostclinicaltrial AT yeganehmohammadreza correlationbetweenheadofbedangleandintraabdominalpressureofintubatedpatientsaprepostclinicaltrial AT ashrafali correlationbetweenheadofbedangleandintraabdominalpressureofintubatedpatientsaprepostclinicaltrial AT hakimihamideh correlationbetweenheadofbedangleandintraabdominalpressureofintubatedpatientsaprepostclinicaltrial AT dehghanimaryam correlationbetweenheadofbedangleandintraabdominalpressureofintubatedpatientsaprepostclinicaltrial |