Cargando…
Evaluation of the relationship between NIRS (near-infrared spectroscopy) and optic nerve sheath diameter measurement in children with increased intracranial pressure: a pilot study
BACKGROUND: The increased intracranial pressure (ICP) syndrome may emerge depending on many different neurological factors and the early diagnosis and treatment are important for the prevention of neurologic damage and related mortality. In recent years, the follow-up of increased ICP with non-invas...
Autores principales: | , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
BioMed Central
2021
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8035715/ https://www.ncbi.nlm.nih.gov/pubmed/33838667 http://dx.doi.org/10.1186/s13052-021-01035-2 |
_version_ | 1783676757859106816 |
---|---|
author | Arslan, Didar Yıldızdaş, Dinçer Horoz, Özden Özgür Aslan, Nagehan İncecik, Faruk |
author_facet | Arslan, Didar Yıldızdaş, Dinçer Horoz, Özden Özgür Aslan, Nagehan İncecik, Faruk |
author_sort | Arslan, Didar |
collection | PubMed |
description | BACKGROUND: The increased intracranial pressure (ICP) syndrome may emerge depending on many different neurological factors and the early diagnosis and treatment are important for the prevention of neurologic damage and related mortality. In recent years, the follow-up of increased ICP with non-invasive methods has been rising. In this study, our objective was to determine the significance and any possible correlation between Optic Nerve Sheath Diameter (ONSD) and Near Infrared Spectroscopy (NIRS) in children with increased ICP. METHODS: Patients who were hospitalized in our pediatric ICU at Çukurova University Medical Faculty between June 2018 and June 2019 due to the suspicion of increased ICP were included in this study. The demographic characteristics of patients, diagnosis at admission, results of the cranial CT and MRI examinations, and results of the simultaneous ONSD and NIRS measurements were recorded. RESULTS: A total of 36 patients were included in our study. With respect to the diagnosis, non-traumatic causes were at the forefront in 30 patients (83.3%), and the most common causes were meningoencephalitis (n = 9; 25%) and non-traumatic bleeding (n = 7; 19.4%). Six of the patients were under the age of one year (16.7%), and the mean values of ONSD and NIRS were 4.8 ± 0.7 mm and 71.1 ± 12.4% respectively in this group. Fourteen patients were in the one to ten year age group and the mean values of ONSD and NIRS were 6.1 ± 0.6 mm and 72.7 ± 9.3% respectively. Sixteen patients were over ten years of age (44.4%), and the mean values of ONSD and NIRS were 5.6 ± 0.7 mm and 74.2 ± 16% respectively. There was no correlation between the ONSD and NIRS values (r:0.307; p = 0.068). CONCLUSION: Our study showed that ONSD measurements were helpful in children with increased ICP and reflected the increase in ICP. However, our study also demonstrated that ONSD was not in correlation with the NIRS monitoring. We believe that there is a need for further studies focused on the use of ONSD and NIRS in the monitoring of increased ICP. |
format | Online Article Text |
id | pubmed-8035715 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2021 |
publisher | BioMed Central |
record_format | MEDLINE/PubMed |
spelling | pubmed-80357152021-04-12 Evaluation of the relationship between NIRS (near-infrared spectroscopy) and optic nerve sheath diameter measurement in children with increased intracranial pressure: a pilot study Arslan, Didar Yıldızdaş, Dinçer Horoz, Özden Özgür Aslan, Nagehan İncecik, Faruk Ital J Pediatr Research BACKGROUND: The increased intracranial pressure (ICP) syndrome may emerge depending on many different neurological factors and the early diagnosis and treatment are important for the prevention of neurologic damage and related mortality. In recent years, the follow-up of increased ICP with non-invasive methods has been rising. In this study, our objective was to determine the significance and any possible correlation between Optic Nerve Sheath Diameter (ONSD) and Near Infrared Spectroscopy (NIRS) in children with increased ICP. METHODS: Patients who were hospitalized in our pediatric ICU at Çukurova University Medical Faculty between June 2018 and June 2019 due to the suspicion of increased ICP were included in this study. The demographic characteristics of patients, diagnosis at admission, results of the cranial CT and MRI examinations, and results of the simultaneous ONSD and NIRS measurements were recorded. RESULTS: A total of 36 patients were included in our study. With respect to the diagnosis, non-traumatic causes were at the forefront in 30 patients (83.3%), and the most common causes were meningoencephalitis (n = 9; 25%) and non-traumatic bleeding (n = 7; 19.4%). Six of the patients were under the age of one year (16.7%), and the mean values of ONSD and NIRS were 4.8 ± 0.7 mm and 71.1 ± 12.4% respectively in this group. Fourteen patients were in the one to ten year age group and the mean values of ONSD and NIRS were 6.1 ± 0.6 mm and 72.7 ± 9.3% respectively. Sixteen patients were over ten years of age (44.4%), and the mean values of ONSD and NIRS were 5.6 ± 0.7 mm and 74.2 ± 16% respectively. There was no correlation between the ONSD and NIRS values (r:0.307; p = 0.068). CONCLUSION: Our study showed that ONSD measurements were helpful in children with increased ICP and reflected the increase in ICP. However, our study also demonstrated that ONSD was not in correlation with the NIRS monitoring. We believe that there is a need for further studies focused on the use of ONSD and NIRS in the monitoring of increased ICP. BioMed Central 2021-04-10 /pmc/articles/PMC8035715/ /pubmed/33838667 http://dx.doi.org/10.1186/s13052-021-01035-2 Text en © The Author(s) 2021 https://creativecommons.org/licenses/by/4.0/Open AccessThis article is licensed under a Creative Commons Attribution 4.0 International License, which permits use, sharing, adaptation, distribution and reproduction in any medium or format, as long as you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons licence, and indicate if changes were made. The images or other third party material in this article are included in the article's Creative Commons licence, unless indicated otherwise in a credit line to the material. If material is not included in the article's Creative Commons licence and your intended use is not permitted by statutory regulation or exceeds the permitted use, you will need to obtain permission directly from the copyright holder. To view a copy of this licence, visit http://creativecommons.org/licenses/by/4.0/ (https://creativecommons.org/licenses/by/4.0/) . The Creative Commons Public Domain Dedication waiver (http://creativecommons.org/publicdomain/zero/1.0/ (https://creativecommons.org/publicdomain/zero/1.0/) ) applies to the data made available in this article, unless otherwise stated in a credit line to the data. |
spellingShingle | Research Arslan, Didar Yıldızdaş, Dinçer Horoz, Özden Özgür Aslan, Nagehan İncecik, Faruk Evaluation of the relationship between NIRS (near-infrared spectroscopy) and optic nerve sheath diameter measurement in children with increased intracranial pressure: a pilot study |
title | Evaluation of the relationship between NIRS (near-infrared spectroscopy) and optic nerve sheath diameter measurement in children with increased intracranial pressure: a pilot study |
title_full | Evaluation of the relationship between NIRS (near-infrared spectroscopy) and optic nerve sheath diameter measurement in children with increased intracranial pressure: a pilot study |
title_fullStr | Evaluation of the relationship between NIRS (near-infrared spectroscopy) and optic nerve sheath diameter measurement in children with increased intracranial pressure: a pilot study |
title_full_unstemmed | Evaluation of the relationship between NIRS (near-infrared spectroscopy) and optic nerve sheath diameter measurement in children with increased intracranial pressure: a pilot study |
title_short | Evaluation of the relationship between NIRS (near-infrared spectroscopy) and optic nerve sheath diameter measurement in children with increased intracranial pressure: a pilot study |
title_sort | evaluation of the relationship between nirs (near-infrared spectroscopy) and optic nerve sheath diameter measurement in children with increased intracranial pressure: a pilot study |
topic | Research |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8035715/ https://www.ncbi.nlm.nih.gov/pubmed/33838667 http://dx.doi.org/10.1186/s13052-021-01035-2 |
work_keys_str_mv | AT arslandidar evaluationoftherelationshipbetweennirsnearinfraredspectroscopyandopticnervesheathdiametermeasurementinchildrenwithincreasedintracranialpressureapilotstudy AT yıldızdasdincer evaluationoftherelationshipbetweennirsnearinfraredspectroscopyandopticnervesheathdiametermeasurementinchildrenwithincreasedintracranialpressureapilotstudy AT horozozdenozgur evaluationoftherelationshipbetweennirsnearinfraredspectroscopyandopticnervesheathdiametermeasurementinchildrenwithincreasedintracranialpressureapilotstudy AT aslannagehan evaluationoftherelationshipbetweennirsnearinfraredspectroscopyandopticnervesheathdiametermeasurementinchildrenwithincreasedintracranialpressureapilotstudy AT incecikfaruk evaluationoftherelationshipbetweennirsnearinfraredspectroscopyandopticnervesheathdiametermeasurementinchildrenwithincreasedintracranialpressureapilotstudy |