Cargando…

Intraoperative nerve monitoring in thyroid surgery: Analysis of recurrent laryngeal nerve identification and operative time

OBJECTIVE: To evaluate the clinical value of intraoperative nerve monitoring (IONM) by comparing the procedure times for thyroidectomies performed with and without IONM. METHODS: A prospective, randomized, controlled study was conducted on 32 patients (representing 41 nerves at risk) undergoing thyr...

Descripción completa

Detalles Bibliográficos
Autores principales: Maneeprasopchoke, Prachya, Chongkolwatana, Cheerasook, Pongsapich, Warut, Iwata, Ayaka J., Kamani, Dipti, Randolph, Gregory W.
Formato: Online Artículo Texto
Lenguaje:English
Publicado: John Wiley & Sons, Inc. 2021
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8035947/
https://www.ncbi.nlm.nih.gov/pubmed/33869769
http://dx.doi.org/10.1002/lio2.543
_version_ 1783676804385472512
author Maneeprasopchoke, Prachya
Chongkolwatana, Cheerasook
Pongsapich, Warut
Iwata, Ayaka J.
Kamani, Dipti
Randolph, Gregory W.
author_facet Maneeprasopchoke, Prachya
Chongkolwatana, Cheerasook
Pongsapich, Warut
Iwata, Ayaka J.
Kamani, Dipti
Randolph, Gregory W.
author_sort Maneeprasopchoke, Prachya
collection PubMed
description OBJECTIVE: To evaluate the clinical value of intraoperative nerve monitoring (IONM) by comparing the procedure times for thyroidectomies performed with and without IONM. METHODS: A prospective, randomized, controlled study was conducted on 32 patients (representing 41 nerves at risk) undergoing thyroidectomies carried out by two experienced head and neck surgeons (CC & WP). Sixteen thyroidectomies were performed without IONM (the “non‐IONM group”), while 16 thyroidectomies were performed with IONM (the “IONM group”). The measured datapoints were setup time, time to visual identification of the recurrent laryngeal nerve (RLN), time to confirm the RLN electrophysiologically, dissection time, and total operative time. RESULTS: With both surgeons, the IONM group had shorter visual times to RLN identification than the non‐IONM group (CC: 3.7 minutes vs 5.3 minutes; WP: 3.4 minutes vs 9.7 minutes). Additionally, the electrophysiological identification time for the IONM group was shorter than the visual identification time for the non‐IONM group. The setup times, dissection times, and total operative times of the 2 groups did not significantly differ (P > .05). No RLN injuries were observed. CONCLUSIONS: IONM reduces the time needed for RLN identification in thyroidectomies. Functional RLN confirmation can reassure surgeons of the operative results. Moreover, use of IONM does not significantly impact setup and total operative times. LEVEL OF EVIDENCE: 2.
format Online
Article
Text
id pubmed-8035947
institution National Center for Biotechnology Information
language English
publishDate 2021
publisher John Wiley & Sons, Inc.
record_format MEDLINE/PubMed
spelling pubmed-80359472021-04-15 Intraoperative nerve monitoring in thyroid surgery: Analysis of recurrent laryngeal nerve identification and operative time Maneeprasopchoke, Prachya Chongkolwatana, Cheerasook Pongsapich, Warut Iwata, Ayaka J. Kamani, Dipti Randolph, Gregory W. Laryngoscope Investig Otolaryngol Thyroid, Parathyroid, and Endocrine OBJECTIVE: To evaluate the clinical value of intraoperative nerve monitoring (IONM) by comparing the procedure times for thyroidectomies performed with and without IONM. METHODS: A prospective, randomized, controlled study was conducted on 32 patients (representing 41 nerves at risk) undergoing thyroidectomies carried out by two experienced head and neck surgeons (CC & WP). Sixteen thyroidectomies were performed without IONM (the “non‐IONM group”), while 16 thyroidectomies were performed with IONM (the “IONM group”). The measured datapoints were setup time, time to visual identification of the recurrent laryngeal nerve (RLN), time to confirm the RLN electrophysiologically, dissection time, and total operative time. RESULTS: With both surgeons, the IONM group had shorter visual times to RLN identification than the non‐IONM group (CC: 3.7 minutes vs 5.3 minutes; WP: 3.4 minutes vs 9.7 minutes). Additionally, the electrophysiological identification time for the IONM group was shorter than the visual identification time for the non‐IONM group. The setup times, dissection times, and total operative times of the 2 groups did not significantly differ (P > .05). No RLN injuries were observed. CONCLUSIONS: IONM reduces the time needed for RLN identification in thyroidectomies. Functional RLN confirmation can reassure surgeons of the operative results. Moreover, use of IONM does not significantly impact setup and total operative times. LEVEL OF EVIDENCE: 2. John Wiley & Sons, Inc. 2021-02-26 /pmc/articles/PMC8035947/ /pubmed/33869769 http://dx.doi.org/10.1002/lio2.543 Text en © 2021 The Authors. Laryngoscope Investigative Otolaryngology published by Wiley Periodicals LLC on behalf of The Triological Society. https://creativecommons.org/licenses/by-nc-nd/4.0/This is an open access article under the terms of the http://creativecommons.org/licenses/by-nc-nd/4.0/ (https://creativecommons.org/licenses/by-nc-nd/4.0/) License, which permits use and distribution in any medium, provided the original work is properly cited, the use is non‐commercial and no modifications or adaptations are made.
spellingShingle Thyroid, Parathyroid, and Endocrine
Maneeprasopchoke, Prachya
Chongkolwatana, Cheerasook
Pongsapich, Warut
Iwata, Ayaka J.
Kamani, Dipti
Randolph, Gregory W.
Intraoperative nerve monitoring in thyroid surgery: Analysis of recurrent laryngeal nerve identification and operative time
title Intraoperative nerve monitoring in thyroid surgery: Analysis of recurrent laryngeal nerve identification and operative time
title_full Intraoperative nerve monitoring in thyroid surgery: Analysis of recurrent laryngeal nerve identification and operative time
title_fullStr Intraoperative nerve monitoring in thyroid surgery: Analysis of recurrent laryngeal nerve identification and operative time
title_full_unstemmed Intraoperative nerve monitoring in thyroid surgery: Analysis of recurrent laryngeal nerve identification and operative time
title_short Intraoperative nerve monitoring in thyroid surgery: Analysis of recurrent laryngeal nerve identification and operative time
title_sort intraoperative nerve monitoring in thyroid surgery: analysis of recurrent laryngeal nerve identification and operative time
topic Thyroid, Parathyroid, and Endocrine
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8035947/
https://www.ncbi.nlm.nih.gov/pubmed/33869769
http://dx.doi.org/10.1002/lio2.543
work_keys_str_mv AT maneeprasopchokeprachya intraoperativenervemonitoringinthyroidsurgeryanalysisofrecurrentlaryngealnerveidentificationandoperativetime
AT chongkolwatanacheerasook intraoperativenervemonitoringinthyroidsurgeryanalysisofrecurrentlaryngealnerveidentificationandoperativetime
AT pongsapichwarut intraoperativenervemonitoringinthyroidsurgeryanalysisofrecurrentlaryngealnerveidentificationandoperativetime
AT iwataayakaj intraoperativenervemonitoringinthyroidsurgeryanalysisofrecurrentlaryngealnerveidentificationandoperativetime
AT kamanidipti intraoperativenervemonitoringinthyroidsurgeryanalysisofrecurrentlaryngealnerveidentificationandoperativetime
AT randolphgregoryw intraoperativenervemonitoringinthyroidsurgeryanalysisofrecurrentlaryngealnerveidentificationandoperativetime