Cargando…

Real-World Performance of a Self-Operated Home Monitoring System for Early Detection of Neovascular Age-Related Macular Degeneration

The real-world performance of a home telemonitoring strategy (ForeseeHome AMD Monitoring System(®), Notal Vision, Inc.,Manassas VA, USA) was evaluated and compared to the device arm of the AREDS2-HOME study among patients with intermediate AMD (iAMD) who converted to neovascular AMD (nAMD). All pati...

Descripción completa

Detalles Bibliográficos
Autores principales: Ho, Allen C., Heier, Jeffrey S., Holekamp, Nancy M., Garfinkel, Richard A., Ladd, Byron, Awh, Carl C., Singh, Rishi P., Sanborn, George E., Jacobs, Jennifer H., Elman, Michael J., Loewenstein, Anat, Eichenbaum, David A.
Formato: Online Artículo Texto
Lenguaje:English
Publicado: MDPI 2021
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8036735/
https://www.ncbi.nlm.nih.gov/pubmed/33806058
http://dx.doi.org/10.3390/jcm10071355
_version_ 1783676979761905664
author Ho, Allen C.
Heier, Jeffrey S.
Holekamp, Nancy M.
Garfinkel, Richard A.
Ladd, Byron
Awh, Carl C.
Singh, Rishi P.
Sanborn, George E.
Jacobs, Jennifer H.
Elman, Michael J.
Loewenstein, Anat
Eichenbaum, David A.
author_facet Ho, Allen C.
Heier, Jeffrey S.
Holekamp, Nancy M.
Garfinkel, Richard A.
Ladd, Byron
Awh, Carl C.
Singh, Rishi P.
Sanborn, George E.
Jacobs, Jennifer H.
Elman, Michael J.
Loewenstein, Anat
Eichenbaum, David A.
author_sort Ho, Allen C.
collection PubMed
description The real-world performance of a home telemonitoring strategy (ForeseeHome AMD Monitoring System(®), Notal Vision, Inc.,Manassas VA, USA) was evaluated and compared to the device arm of the AREDS2-HOME study among patients with intermediate AMD (iAMD) who converted to neovascular AMD (nAMD). All patients with confirmed conversion to nAMD who used the home monitoring system from 10/2009 through 9/2018 were identified by Notal Vision Diagnostic Clinic’s medical records. Selected outcome variables were evaluated, including visual acuity (VA) at baseline and at conversion, and change in visual acuity (VA) from baseline to time of conversion. In total, 8991 patients performed 3,200,999 tests at a frequency of 5.6 ± 3.2 times/week. The 306 eyes that converted from iAMD to nAMD over the study period (a 2.7% annual rate) were included in the analyses. There was a median (interquartile range) change of −3.0 (0.0–(−10.0)) letters among converted eyes, 81% [95% confidence interval (72–88%)] maintained a VA ≥ 20/40 at the time of conversion, while 69% of the conversion detections were triggered by system alerts. The real-world performance of an at-home testing strategy was similar to that reported for the device arm of the AREDS2-HOME study. The home telemonitoring system can markedly increase early detection of conversion to nAMD.
format Online
Article
Text
id pubmed-8036735
institution National Center for Biotechnology Information
language English
publishDate 2021
publisher MDPI
record_format MEDLINE/PubMed
spelling pubmed-80367352021-04-12 Real-World Performance of a Self-Operated Home Monitoring System for Early Detection of Neovascular Age-Related Macular Degeneration Ho, Allen C. Heier, Jeffrey S. Holekamp, Nancy M. Garfinkel, Richard A. Ladd, Byron Awh, Carl C. Singh, Rishi P. Sanborn, George E. Jacobs, Jennifer H. Elman, Michael J. Loewenstein, Anat Eichenbaum, David A. J Clin Med Article The real-world performance of a home telemonitoring strategy (ForeseeHome AMD Monitoring System(®), Notal Vision, Inc.,Manassas VA, USA) was evaluated and compared to the device arm of the AREDS2-HOME study among patients with intermediate AMD (iAMD) who converted to neovascular AMD (nAMD). All patients with confirmed conversion to nAMD who used the home monitoring system from 10/2009 through 9/2018 were identified by Notal Vision Diagnostic Clinic’s medical records. Selected outcome variables were evaluated, including visual acuity (VA) at baseline and at conversion, and change in visual acuity (VA) from baseline to time of conversion. In total, 8991 patients performed 3,200,999 tests at a frequency of 5.6 ± 3.2 times/week. The 306 eyes that converted from iAMD to nAMD over the study period (a 2.7% annual rate) were included in the analyses. There was a median (interquartile range) change of −3.0 (0.0–(−10.0)) letters among converted eyes, 81% [95% confidence interval (72–88%)] maintained a VA ≥ 20/40 at the time of conversion, while 69% of the conversion detections were triggered by system alerts. The real-world performance of an at-home testing strategy was similar to that reported for the device arm of the AREDS2-HOME study. The home telemonitoring system can markedly increase early detection of conversion to nAMD. MDPI 2021-03-25 /pmc/articles/PMC8036735/ /pubmed/33806058 http://dx.doi.org/10.3390/jcm10071355 Text en © 2021 by the authors. https://creativecommons.org/licenses/by/4.0/Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (http://creativecommons.org/licenses/by/4.0/ (https://creativecommons.org/licenses/by/4.0/) ).
spellingShingle Article
Ho, Allen C.
Heier, Jeffrey S.
Holekamp, Nancy M.
Garfinkel, Richard A.
Ladd, Byron
Awh, Carl C.
Singh, Rishi P.
Sanborn, George E.
Jacobs, Jennifer H.
Elman, Michael J.
Loewenstein, Anat
Eichenbaum, David A.
Real-World Performance of a Self-Operated Home Monitoring System for Early Detection of Neovascular Age-Related Macular Degeneration
title Real-World Performance of a Self-Operated Home Monitoring System for Early Detection of Neovascular Age-Related Macular Degeneration
title_full Real-World Performance of a Self-Operated Home Monitoring System for Early Detection of Neovascular Age-Related Macular Degeneration
title_fullStr Real-World Performance of a Self-Operated Home Monitoring System for Early Detection of Neovascular Age-Related Macular Degeneration
title_full_unstemmed Real-World Performance of a Self-Operated Home Monitoring System for Early Detection of Neovascular Age-Related Macular Degeneration
title_short Real-World Performance of a Self-Operated Home Monitoring System for Early Detection of Neovascular Age-Related Macular Degeneration
title_sort real-world performance of a self-operated home monitoring system for early detection of neovascular age-related macular degeneration
topic Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8036735/
https://www.ncbi.nlm.nih.gov/pubmed/33806058
http://dx.doi.org/10.3390/jcm10071355
work_keys_str_mv AT hoallenc realworldperformanceofaselfoperatedhomemonitoringsystemforearlydetectionofneovascularagerelatedmaculardegeneration
AT heierjeffreys realworldperformanceofaselfoperatedhomemonitoringsystemforearlydetectionofneovascularagerelatedmaculardegeneration
AT holekampnancym realworldperformanceofaselfoperatedhomemonitoringsystemforearlydetectionofneovascularagerelatedmaculardegeneration
AT garfinkelricharda realworldperformanceofaselfoperatedhomemonitoringsystemforearlydetectionofneovascularagerelatedmaculardegeneration
AT laddbyron realworldperformanceofaselfoperatedhomemonitoringsystemforearlydetectionofneovascularagerelatedmaculardegeneration
AT awhcarlc realworldperformanceofaselfoperatedhomemonitoringsystemforearlydetectionofneovascularagerelatedmaculardegeneration
AT singhriship realworldperformanceofaselfoperatedhomemonitoringsystemforearlydetectionofneovascularagerelatedmaculardegeneration
AT sanborngeorgee realworldperformanceofaselfoperatedhomemonitoringsystemforearlydetectionofneovascularagerelatedmaculardegeneration
AT jacobsjenniferh realworldperformanceofaselfoperatedhomemonitoringsystemforearlydetectionofneovascularagerelatedmaculardegeneration
AT elmanmichaelj realworldperformanceofaselfoperatedhomemonitoringsystemforearlydetectionofneovascularagerelatedmaculardegeneration
AT loewensteinanat realworldperformanceofaselfoperatedhomemonitoringsystemforearlydetectionofneovascularagerelatedmaculardegeneration
AT eichenbaumdavida realworldperformanceofaselfoperatedhomemonitoringsystemforearlydetectionofneovascularagerelatedmaculardegeneration