Cargando…
Electrical Performance of Polymer-Insulated Rail Brackets of DC Transit Subjected to Lightning Induced Overvoltage
The fourth rail transit is an interesting topic to be shared and accessed by the community within that area of expertise. Several ongoing works are currently being conducted especially in the aspects of system technical performances including the rail bracket component and the sensitivity analyses o...
Autores principales: | , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
MDPI
2021
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8036920/ https://www.ncbi.nlm.nih.gov/pubmed/33805583 http://dx.doi.org/10.3390/ma14071684 |
_version_ | 1783677022712627200 |
---|---|
author | Abd Rahman, Farah Asyikin Ab Kadir, Mohd Zainal Abidin Ungku Amirulddin, Ungku Anisa Osman, Miszaina |
author_facet | Abd Rahman, Farah Asyikin Ab Kadir, Mohd Zainal Abidin Ungku Amirulddin, Ungku Anisa Osman, Miszaina |
author_sort | Abd Rahman, Farah Asyikin |
collection | PubMed |
description | The fourth rail transit is an interesting topic to be shared and accessed by the community within that area of expertise. Several ongoing works are currently being conducted especially in the aspects of system technical performances including the rail bracket component and the sensitivity analyses on the various rail designs. Furthermore, the lightning surge study on railway electrification is significant due to the fact that only a handful of publications are available in this regard, especially on the fourth rail transit. For this reason, this paper presents a study on the electrical performance of a fourth rail Direct Current (DC) urban transit affected by an indirect lightning strike. The indirect lightning strike was modelled by means of the Rusck model and the sum of two Heidler functions. The simulations were carried out using the EMTP-RV software which included the performance comparison of polymer-insulated rail brackets, namely the Cast Epoxy (CE), the Cycloaliphatic Epoxy A (CEA), and the Glass Reinforced Plastic (GRP) together with the station arresters when subjected by 30 kA (5/80 µs) and 90 kA (9/200 µs) lightning currents. The results obtained demonstrated that the GRP material has been able to slightly lower its induced overvoltage as compared to other materials, especially for the case of 90 kA (9/200 µs), and thus serves better coordination with the station arresters. This improvement has also reflected on the recorded residual voltage and energy absorption capacity of the arrester, respectively. |
format | Online Article Text |
id | pubmed-8036920 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2021 |
publisher | MDPI |
record_format | MEDLINE/PubMed |
spelling | pubmed-80369202021-04-12 Electrical Performance of Polymer-Insulated Rail Brackets of DC Transit Subjected to Lightning Induced Overvoltage Abd Rahman, Farah Asyikin Ab Kadir, Mohd Zainal Abidin Ungku Amirulddin, Ungku Anisa Osman, Miszaina Materials (Basel) Article The fourth rail transit is an interesting topic to be shared and accessed by the community within that area of expertise. Several ongoing works are currently being conducted especially in the aspects of system technical performances including the rail bracket component and the sensitivity analyses on the various rail designs. Furthermore, the lightning surge study on railway electrification is significant due to the fact that only a handful of publications are available in this regard, especially on the fourth rail transit. For this reason, this paper presents a study on the electrical performance of a fourth rail Direct Current (DC) urban transit affected by an indirect lightning strike. The indirect lightning strike was modelled by means of the Rusck model and the sum of two Heidler functions. The simulations were carried out using the EMTP-RV software which included the performance comparison of polymer-insulated rail brackets, namely the Cast Epoxy (CE), the Cycloaliphatic Epoxy A (CEA), and the Glass Reinforced Plastic (GRP) together with the station arresters when subjected by 30 kA (5/80 µs) and 90 kA (9/200 µs) lightning currents. The results obtained demonstrated that the GRP material has been able to slightly lower its induced overvoltage as compared to other materials, especially for the case of 90 kA (9/200 µs), and thus serves better coordination with the station arresters. This improvement has also reflected on the recorded residual voltage and energy absorption capacity of the arrester, respectively. MDPI 2021-03-29 /pmc/articles/PMC8036920/ /pubmed/33805583 http://dx.doi.org/10.3390/ma14071684 Text en © 2021 by the authors. https://creativecommons.org/licenses/by/4.0/Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (http://creativecommons.org/licenses/by/4.0/ (https://creativecommons.org/licenses/by/4.0/) ). |
spellingShingle | Article Abd Rahman, Farah Asyikin Ab Kadir, Mohd Zainal Abidin Ungku Amirulddin, Ungku Anisa Osman, Miszaina Electrical Performance of Polymer-Insulated Rail Brackets of DC Transit Subjected to Lightning Induced Overvoltage |
title | Electrical Performance of Polymer-Insulated Rail Brackets of DC Transit Subjected to Lightning Induced Overvoltage |
title_full | Electrical Performance of Polymer-Insulated Rail Brackets of DC Transit Subjected to Lightning Induced Overvoltage |
title_fullStr | Electrical Performance of Polymer-Insulated Rail Brackets of DC Transit Subjected to Lightning Induced Overvoltage |
title_full_unstemmed | Electrical Performance of Polymer-Insulated Rail Brackets of DC Transit Subjected to Lightning Induced Overvoltage |
title_short | Electrical Performance of Polymer-Insulated Rail Brackets of DC Transit Subjected to Lightning Induced Overvoltage |
title_sort | electrical performance of polymer-insulated rail brackets of dc transit subjected to lightning induced overvoltage |
topic | Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8036920/ https://www.ncbi.nlm.nih.gov/pubmed/33805583 http://dx.doi.org/10.3390/ma14071684 |
work_keys_str_mv | AT abdrahmanfarahasyikin electricalperformanceofpolymerinsulatedrailbracketsofdctransitsubjectedtolightninginducedovervoltage AT abkadirmohdzainalabidin electricalperformanceofpolymerinsulatedrailbracketsofdctransitsubjectedtolightninginducedovervoltage AT ungkuamirulddinungkuanisa electricalperformanceofpolymerinsulatedrailbracketsofdctransitsubjectedtolightninginducedovervoltage AT osmanmiszaina electricalperformanceofpolymerinsulatedrailbracketsofdctransitsubjectedtolightninginducedovervoltage |