Cargando…

An Embedded-Sensor Approach for Concrete Resistivity Measurement in On-Site Corrosion Monitoring: Cell Constants Determination

The concrete electrical resistivity is a prominent parameter in structural health monitoring, since, along with corrosion potential, it provides relevant qualitative diagnosis of the reinforcement corrosion. This study proposes a simple expression to reliable determine resistivity from the concrete...

Descripción completa

Detalles Bibliográficos
Autores principales: Ramón, Jose Enrique, Martínez, Isabel, Gandía-Romero, José Manuel, Soto, Juan
Formato: Online Artículo Texto
Lenguaje:English
Publicado: MDPI 2021
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8038218/
https://www.ncbi.nlm.nih.gov/pubmed/33918485
http://dx.doi.org/10.3390/s21072481
_version_ 1783677324404719616
author Ramón, Jose Enrique
Martínez, Isabel
Gandía-Romero, José Manuel
Soto, Juan
author_facet Ramón, Jose Enrique
Martínez, Isabel
Gandía-Romero, José Manuel
Soto, Juan
author_sort Ramón, Jose Enrique
collection PubMed
description The concrete electrical resistivity is a prominent parameter in structural health monitoring, since, along with corrosion potential, it provides relevant qualitative diagnosis of the reinforcement corrosion. This study proposes a simple expression to reliable determine resistivity from the concrete electrical resistance (R(E)) provided by the corrosion sensor of the Integrated Network of Sensors for Smart Corrosion Monitoring (INESSCOM) we have developed. The novelty here is that distinct from common resistivity sensors, the cell constants obtained by the proposed expression are intended to be valid for any sensor implementation scenario. This was ensured by studying most significant geometrical features of the sensor in a wide set of calibration solutions. This embedded-sensor approach is intended to be applicable for R(E) measurements obtained both using potential step voltammetry (PSV, used in the INESSCOM sensor for corrosion rate measurement) and alternating current methods. In this regard, we present a simple protocol to reliably determine R(E), and therefore resistivity, from PSV measurements. It consists in adding a very short potentiostatic pulse to the original technique. In this way, we are able to easy monitor resistivity along with corrosion rate through a single sensor, an advantage which is not usual in structural health monitoring.
format Online
Article
Text
id pubmed-8038218
institution National Center for Biotechnology Information
language English
publishDate 2021
publisher MDPI
record_format MEDLINE/PubMed
spelling pubmed-80382182021-04-12 An Embedded-Sensor Approach for Concrete Resistivity Measurement in On-Site Corrosion Monitoring: Cell Constants Determination Ramón, Jose Enrique Martínez, Isabel Gandía-Romero, José Manuel Soto, Juan Sensors (Basel) Article The concrete electrical resistivity is a prominent parameter in structural health monitoring, since, along with corrosion potential, it provides relevant qualitative diagnosis of the reinforcement corrosion. This study proposes a simple expression to reliable determine resistivity from the concrete electrical resistance (R(E)) provided by the corrosion sensor of the Integrated Network of Sensors for Smart Corrosion Monitoring (INESSCOM) we have developed. The novelty here is that distinct from common resistivity sensors, the cell constants obtained by the proposed expression are intended to be valid for any sensor implementation scenario. This was ensured by studying most significant geometrical features of the sensor in a wide set of calibration solutions. This embedded-sensor approach is intended to be applicable for R(E) measurements obtained both using potential step voltammetry (PSV, used in the INESSCOM sensor for corrosion rate measurement) and alternating current methods. In this regard, we present a simple protocol to reliably determine R(E), and therefore resistivity, from PSV measurements. It consists in adding a very short potentiostatic pulse to the original technique. In this way, we are able to easy monitor resistivity along with corrosion rate through a single sensor, an advantage which is not usual in structural health monitoring. MDPI 2021-04-02 /pmc/articles/PMC8038218/ /pubmed/33918485 http://dx.doi.org/10.3390/s21072481 Text en © 2021 by the authors. https://creativecommons.org/licenses/by/4.0/Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (https://creativecommons.org/licenses/by/4.0/).
spellingShingle Article
Ramón, Jose Enrique
Martínez, Isabel
Gandía-Romero, José Manuel
Soto, Juan
An Embedded-Sensor Approach for Concrete Resistivity Measurement in On-Site Corrosion Monitoring: Cell Constants Determination
title An Embedded-Sensor Approach for Concrete Resistivity Measurement in On-Site Corrosion Monitoring: Cell Constants Determination
title_full An Embedded-Sensor Approach for Concrete Resistivity Measurement in On-Site Corrosion Monitoring: Cell Constants Determination
title_fullStr An Embedded-Sensor Approach for Concrete Resistivity Measurement in On-Site Corrosion Monitoring: Cell Constants Determination
title_full_unstemmed An Embedded-Sensor Approach for Concrete Resistivity Measurement in On-Site Corrosion Monitoring: Cell Constants Determination
title_short An Embedded-Sensor Approach for Concrete Resistivity Measurement in On-Site Corrosion Monitoring: Cell Constants Determination
title_sort embedded-sensor approach for concrete resistivity measurement in on-site corrosion monitoring: cell constants determination
topic Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8038218/
https://www.ncbi.nlm.nih.gov/pubmed/33918485
http://dx.doi.org/10.3390/s21072481
work_keys_str_mv AT ramonjoseenrique anembeddedsensorapproachforconcreteresistivitymeasurementinonsitecorrosionmonitoringcellconstantsdetermination
AT martinezisabel anembeddedsensorapproachforconcreteresistivitymeasurementinonsitecorrosionmonitoringcellconstantsdetermination
AT gandiaromerojosemanuel anembeddedsensorapproachforconcreteresistivitymeasurementinonsitecorrosionmonitoringcellconstantsdetermination
AT sotojuan anembeddedsensorapproachforconcreteresistivitymeasurementinonsitecorrosionmonitoringcellconstantsdetermination
AT ramonjoseenrique embeddedsensorapproachforconcreteresistivitymeasurementinonsitecorrosionmonitoringcellconstantsdetermination
AT martinezisabel embeddedsensorapproachforconcreteresistivitymeasurementinonsitecorrosionmonitoringcellconstantsdetermination
AT gandiaromerojosemanuel embeddedsensorapproachforconcreteresistivitymeasurementinonsitecorrosionmonitoringcellconstantsdetermination
AT sotojuan embeddedsensorapproachforconcreteresistivitymeasurementinonsitecorrosionmonitoringcellconstantsdetermination