Cargando…
Systematic Review of Clinical Applications of CAD/CAM Technology for Craniofacial Implants Placement and Manufacturing of Nasal Prostheses
The aim of this systematic review was to gather the clinical and laboratory applications of CAD/CAM technology for preoperative planning, designing of an attachment system, and manufacturing of nasal prostheses. According to Preferred Reporting Items for Systematic Reviews and Meta-Analyses (PRISMA)...
Autores principales: | , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
MDPI
2021
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8038514/ https://www.ncbi.nlm.nih.gov/pubmed/33916853 http://dx.doi.org/10.3390/ijerph18073756 |
_version_ | 1783677393166139392 |
---|---|
author | Tanveer, Waqas Ridwan-Pramana, Angela Molinero-Mourelle, Pedro Koolstra, Jan Harm Forouzanfar, Tymour |
author_facet | Tanveer, Waqas Ridwan-Pramana, Angela Molinero-Mourelle, Pedro Koolstra, Jan Harm Forouzanfar, Tymour |
author_sort | Tanveer, Waqas |
collection | PubMed |
description | The aim of this systematic review was to gather the clinical and laboratory applications of CAD/CAM technology for preoperative planning, designing of an attachment system, and manufacturing of nasal prostheses. According to Preferred Reporting Items for Systematic Reviews and Meta-Analyses (PRISMA) guidelines, an electronic search was carried out. Only human clinical studies involving digital planning for the rehabilitation of facial defects were included. A total of 21 studies were included with 23 patients, which were virtually planned through different planning software. The most common preoperative data for digital planning were CT scans in nine cases, CBCT in six cases, and laser scans in six cases. The reported planning softwares were Mimics in six cases, Geomagic Studio software in six cases, ZBrush in four cases, and Freeform plus software in four cases. Ten surgical templates were designed and printed to place 36 implants after digital planning, while post-operative assessment was done in two cases to check the accuracy of planned implants. Digital 3D planning software was reported for presurgical planning and craniofacial implants placement, fabrication of molds, designing of implants, designing of retentive attachments, and printing of silicone prostheses. Digital technology has been claimed to reduce the clinical and laboratory time; however, the equipment cost is still one of the limitations. |
format | Online Article Text |
id | pubmed-8038514 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2021 |
publisher | MDPI |
record_format | MEDLINE/PubMed |
spelling | pubmed-80385142021-04-12 Systematic Review of Clinical Applications of CAD/CAM Technology for Craniofacial Implants Placement and Manufacturing of Nasal Prostheses Tanveer, Waqas Ridwan-Pramana, Angela Molinero-Mourelle, Pedro Koolstra, Jan Harm Forouzanfar, Tymour Int J Environ Res Public Health Review The aim of this systematic review was to gather the clinical and laboratory applications of CAD/CAM technology for preoperative planning, designing of an attachment system, and manufacturing of nasal prostheses. According to Preferred Reporting Items for Systematic Reviews and Meta-Analyses (PRISMA) guidelines, an electronic search was carried out. Only human clinical studies involving digital planning for the rehabilitation of facial defects were included. A total of 21 studies were included with 23 patients, which were virtually planned through different planning software. The most common preoperative data for digital planning were CT scans in nine cases, CBCT in six cases, and laser scans in six cases. The reported planning softwares were Mimics in six cases, Geomagic Studio software in six cases, ZBrush in four cases, and Freeform plus software in four cases. Ten surgical templates were designed and printed to place 36 implants after digital planning, while post-operative assessment was done in two cases to check the accuracy of planned implants. Digital 3D planning software was reported for presurgical planning and craniofacial implants placement, fabrication of molds, designing of implants, designing of retentive attachments, and printing of silicone prostheses. Digital technology has been claimed to reduce the clinical and laboratory time; however, the equipment cost is still one of the limitations. MDPI 2021-04-03 /pmc/articles/PMC8038514/ /pubmed/33916853 http://dx.doi.org/10.3390/ijerph18073756 Text en © 2021 by the authors. https://creativecommons.org/licenses/by/4.0/Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (https://creativecommons.org/licenses/by/4.0/). |
spellingShingle | Review Tanveer, Waqas Ridwan-Pramana, Angela Molinero-Mourelle, Pedro Koolstra, Jan Harm Forouzanfar, Tymour Systematic Review of Clinical Applications of CAD/CAM Technology for Craniofacial Implants Placement and Manufacturing of Nasal Prostheses |
title | Systematic Review of Clinical Applications of CAD/CAM Technology for Craniofacial Implants Placement and Manufacturing of Nasal Prostheses |
title_full | Systematic Review of Clinical Applications of CAD/CAM Technology for Craniofacial Implants Placement and Manufacturing of Nasal Prostheses |
title_fullStr | Systematic Review of Clinical Applications of CAD/CAM Technology for Craniofacial Implants Placement and Manufacturing of Nasal Prostheses |
title_full_unstemmed | Systematic Review of Clinical Applications of CAD/CAM Technology for Craniofacial Implants Placement and Manufacturing of Nasal Prostheses |
title_short | Systematic Review of Clinical Applications of CAD/CAM Technology for Craniofacial Implants Placement and Manufacturing of Nasal Prostheses |
title_sort | systematic review of clinical applications of cad/cam technology for craniofacial implants placement and manufacturing of nasal prostheses |
topic | Review |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8038514/ https://www.ncbi.nlm.nih.gov/pubmed/33916853 http://dx.doi.org/10.3390/ijerph18073756 |
work_keys_str_mv | AT tanveerwaqas systematicreviewofclinicalapplicationsofcadcamtechnologyforcraniofacialimplantsplacementandmanufacturingofnasalprostheses AT ridwanpramanaangela systematicreviewofclinicalapplicationsofcadcamtechnologyforcraniofacialimplantsplacementandmanufacturingofnasalprostheses AT molineromourellepedro systematicreviewofclinicalapplicationsofcadcamtechnologyforcraniofacialimplantsplacementandmanufacturingofnasalprostheses AT koolstrajanharm systematicreviewofclinicalapplicationsofcadcamtechnologyforcraniofacialimplantsplacementandmanufacturingofnasalprostheses AT forouzanfartymour systematicreviewofclinicalapplicationsofcadcamtechnologyforcraniofacialimplantsplacementandmanufacturingofnasalprostheses |