Post Fire Residual Strength of the Wall-Slab Using Siliceous Concrete
It is very important to understand the residual performance of a structure for repair, retrofit, and reuse of a building after a fire. In this study, an experiment is conducted on the residual performance of real-scale siliceous aggregates-based reinforced concrete (RC) wall-slab connection (WSC) af...
Autores principales: | , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
MDPI
2021
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8038594/ https://www.ncbi.nlm.nih.gov/pubmed/33916382 http://dx.doi.org/10.3390/ma14071793 |
_version_ | 1783677411598008320 |
---|---|
author | Lee, Su-Hyeon Choi, Byong-Jeong |
author_facet | Lee, Su-Hyeon Choi, Byong-Jeong |
author_sort | Lee, Su-Hyeon |
collection | PubMed |
description | It is very important to understand the residual performance of a structure for repair, retrofit, and reuse of a building after a fire. In this study, an experiment is conducted on the residual performance of real-scale siliceous aggregates-based reinforced concrete (RC) wall-slab connection (WSC) after the fire, using the simple calculation method (SCM) of standards (Eurocode, ACI, and NIST) for comparison and analysis. A description of the WSC specimen and detailed methods for the experiment are introduced. The fire test is conducted according to the fire scenario by dividing it into one-sided and two-sided heating based on the wall. In the post-fire residual performance test, the load–displacement and moment-deflection angle relationship according to the fire time are derived and discussed. In addition, the residual mechanical properties after the fire are derived for the 35 MPa siliceous concrete used in the wall-slab specimen. The load and moment, derived using SCM, are compared with the experimental results. Our results show that the one-sided heating test result is close to that of Eurocode’s SCM, and the two-sided heating test result is close to that of ACI (NIST)’s SCM. This study provides a database on the residual strength through a real-scale fire test and standard comparison. |
format | Online Article Text |
id | pubmed-8038594 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2021 |
publisher | MDPI |
record_format | MEDLINE/PubMed |
spelling | pubmed-80385942021-04-12 Post Fire Residual Strength of the Wall-Slab Using Siliceous Concrete Lee, Su-Hyeon Choi, Byong-Jeong Materials (Basel) Article It is very important to understand the residual performance of a structure for repair, retrofit, and reuse of a building after a fire. In this study, an experiment is conducted on the residual performance of real-scale siliceous aggregates-based reinforced concrete (RC) wall-slab connection (WSC) after the fire, using the simple calculation method (SCM) of standards (Eurocode, ACI, and NIST) for comparison and analysis. A description of the WSC specimen and detailed methods for the experiment are introduced. The fire test is conducted according to the fire scenario by dividing it into one-sided and two-sided heating based on the wall. In the post-fire residual performance test, the load–displacement and moment-deflection angle relationship according to the fire time are derived and discussed. In addition, the residual mechanical properties after the fire are derived for the 35 MPa siliceous concrete used in the wall-slab specimen. The load and moment, derived using SCM, are compared with the experimental results. Our results show that the one-sided heating test result is close to that of Eurocode’s SCM, and the two-sided heating test result is close to that of ACI (NIST)’s SCM. This study provides a database on the residual strength through a real-scale fire test and standard comparison. MDPI 2021-04-05 /pmc/articles/PMC8038594/ /pubmed/33916382 http://dx.doi.org/10.3390/ma14071793 Text en © 2021 by the authors. https://creativecommons.org/licenses/by/4.0/Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (https://creativecommons.org/licenses/by/4.0/). |
spellingShingle | Article Lee, Su-Hyeon Choi, Byong-Jeong Post Fire Residual Strength of the Wall-Slab Using Siliceous Concrete |
title | Post Fire Residual Strength of the Wall-Slab Using Siliceous Concrete |
title_full | Post Fire Residual Strength of the Wall-Slab Using Siliceous Concrete |
title_fullStr | Post Fire Residual Strength of the Wall-Slab Using Siliceous Concrete |
title_full_unstemmed | Post Fire Residual Strength of the Wall-Slab Using Siliceous Concrete |
title_short | Post Fire Residual Strength of the Wall-Slab Using Siliceous Concrete |
title_sort | post fire residual strength of the wall-slab using siliceous concrete |
topic | Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8038594/ https://www.ncbi.nlm.nih.gov/pubmed/33916382 http://dx.doi.org/10.3390/ma14071793 |
work_keys_str_mv | AT leesuhyeon postfireresidualstrengthofthewallslabusingsiliceousconcrete AT choibyongjeong postfireresidualstrengthofthewallslabusingsiliceousconcrete |