Cargando…

Common-Mode Voltage Reduction in Capacitive Sensing of Biosignal Using Capacitive Grounding and DRL Electrode

A capacitive measurement of the biosignals is a very comfortable and unobtrusive way suitable for long-term and wearable monitoring of health conditions. This type of sensing is very susceptible to noise from the surroundings. One of the main noise sources is power-line noise, which acts as a common...

Descripción completa

Detalles Bibliográficos
Autores principales: Bednar, Tadeas, Babusiak, Branko, Labuda, Michal, Smetana, Milan, Borik, Stefan
Formato: Online Artículo Texto
Lenguaje:English
Publicado: MDPI 2021
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8038844/
https://www.ncbi.nlm.nih.gov/pubmed/33917589
http://dx.doi.org/10.3390/s21072568
_version_ 1783677469629349888
author Bednar, Tadeas
Babusiak, Branko
Labuda, Michal
Smetana, Milan
Borik, Stefan
author_facet Bednar, Tadeas
Babusiak, Branko
Labuda, Michal
Smetana, Milan
Borik, Stefan
author_sort Bednar, Tadeas
collection PubMed
description A capacitive measurement of the biosignals is a very comfortable and unobtrusive way suitable for long-term and wearable monitoring of health conditions. This type of sensing is very susceptible to noise from the surroundings. One of the main noise sources is power-line noise, which acts as a common-mode voltage at the input terminals of the acquisition unit. The origin and methods of noise reduction are described on electric models. Two methods of noise removal are modeled and experimentally verified in the paper. The first method uses a passive capacitive grounding electrode, and the second uses an active capacitive Driven Right Leg (DRL) electrode. The effect of grounding electrode size on noise suppression is experimentally investigated. The increasing electrode area reduces power-line noise: the power of power-line frequency within the measured signal is 70.96 dB, 59.13 dB, and 43.44 dB for a grounding electrode area of 1650 cm(2), 3300 cm(2), and 4950 cm(2), respectively. The capacitive DRL electrode shows better efficiency in common-mode noise rejection than the grounding electrode. When using an electrode area of 1650 cm(2), the DRL achieved 46.3 dB better attenuation than the grounding electrode at power-line frequency. In contrast to the grounding electrode, the DRL electrode reduces a capacitive measurement system’s financial costs due to the smaller electrode area made of the costly conductive textile.
format Online
Article
Text
id pubmed-8038844
institution National Center for Biotechnology Information
language English
publishDate 2021
publisher MDPI
record_format MEDLINE/PubMed
spelling pubmed-80388442021-04-12 Common-Mode Voltage Reduction in Capacitive Sensing of Biosignal Using Capacitive Grounding and DRL Electrode Bednar, Tadeas Babusiak, Branko Labuda, Michal Smetana, Milan Borik, Stefan Sensors (Basel) Article A capacitive measurement of the biosignals is a very comfortable and unobtrusive way suitable for long-term and wearable monitoring of health conditions. This type of sensing is very susceptible to noise from the surroundings. One of the main noise sources is power-line noise, which acts as a common-mode voltage at the input terminals of the acquisition unit. The origin and methods of noise reduction are described on electric models. Two methods of noise removal are modeled and experimentally verified in the paper. The first method uses a passive capacitive grounding electrode, and the second uses an active capacitive Driven Right Leg (DRL) electrode. The effect of grounding electrode size on noise suppression is experimentally investigated. The increasing electrode area reduces power-line noise: the power of power-line frequency within the measured signal is 70.96 dB, 59.13 dB, and 43.44 dB for a grounding electrode area of 1650 cm(2), 3300 cm(2), and 4950 cm(2), respectively. The capacitive DRL electrode shows better efficiency in common-mode noise rejection than the grounding electrode. When using an electrode area of 1650 cm(2), the DRL achieved 46.3 dB better attenuation than the grounding electrode at power-line frequency. In contrast to the grounding electrode, the DRL electrode reduces a capacitive measurement system’s financial costs due to the smaller electrode area made of the costly conductive textile. MDPI 2021-04-06 /pmc/articles/PMC8038844/ /pubmed/33917589 http://dx.doi.org/10.3390/s21072568 Text en © 2021 by the authors. https://creativecommons.org/licenses/by/4.0/Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (https://creativecommons.org/licenses/by/4.0/).
spellingShingle Article
Bednar, Tadeas
Babusiak, Branko
Labuda, Michal
Smetana, Milan
Borik, Stefan
Common-Mode Voltage Reduction in Capacitive Sensing of Biosignal Using Capacitive Grounding and DRL Electrode
title Common-Mode Voltage Reduction in Capacitive Sensing of Biosignal Using Capacitive Grounding and DRL Electrode
title_full Common-Mode Voltage Reduction in Capacitive Sensing of Biosignal Using Capacitive Grounding and DRL Electrode
title_fullStr Common-Mode Voltage Reduction in Capacitive Sensing of Biosignal Using Capacitive Grounding and DRL Electrode
title_full_unstemmed Common-Mode Voltage Reduction in Capacitive Sensing of Biosignal Using Capacitive Grounding and DRL Electrode
title_short Common-Mode Voltage Reduction in Capacitive Sensing of Biosignal Using Capacitive Grounding and DRL Electrode
title_sort common-mode voltage reduction in capacitive sensing of biosignal using capacitive grounding and drl electrode
topic Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8038844/
https://www.ncbi.nlm.nih.gov/pubmed/33917589
http://dx.doi.org/10.3390/s21072568
work_keys_str_mv AT bednartadeas commonmodevoltagereductionincapacitivesensingofbiosignalusingcapacitivegroundinganddrlelectrode
AT babusiakbranko commonmodevoltagereductionincapacitivesensingofbiosignalusingcapacitivegroundinganddrlelectrode
AT labudamichal commonmodevoltagereductionincapacitivesensingofbiosignalusingcapacitivegroundinganddrlelectrode
AT smetanamilan commonmodevoltagereductionincapacitivesensingofbiosignalusingcapacitivegroundinganddrlelectrode
AT borikstefan commonmodevoltagereductionincapacitivesensingofbiosignalusingcapacitivegroundinganddrlelectrode