Cargando…

Endoscopic Ultrasound-Guided Fine Needle Biopsy Needles Provide Higher Diagnostic Yield Compared to Endoscopic Ultrasound-Guided Fine Needle Aspiration Needles When Sampling Solid Pancreatic Lesions: A Meta-Analysis

BACKGROUND/AIMS: Studies comparing the utility of endoscopic ultrasound-guided fine needle aspiration (EUS-FNA) and endoscopic ultrasound-guided fine needle biopsy (EUS-FNB) for solid pancreatic lesions have been inconclusive with no clear superiority. The aim of this meta-analysis was to compare th...

Descripción completa

Detalles Bibliográficos
Autores principales: Renelus, Benjamin D., Jamorabo, Daniel S., Boston, Iman, Briggs, William M., Poneros, John M.
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Korean Society of Gastrointestinal Endoscopy 2021
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8039752/
https://www.ncbi.nlm.nih.gov/pubmed/32892519
http://dx.doi.org/10.5946/ce.2020.101
_version_ 1783677663130419200
author Renelus, Benjamin D.
Jamorabo, Daniel S.
Boston, Iman
Briggs, William M.
Poneros, John M.
author_facet Renelus, Benjamin D.
Jamorabo, Daniel S.
Boston, Iman
Briggs, William M.
Poneros, John M.
author_sort Renelus, Benjamin D.
collection PubMed
description BACKGROUND/AIMS: Studies comparing the utility of endoscopic ultrasound-guided fine needle aspiration (EUS-FNA) and endoscopic ultrasound-guided fine needle biopsy (EUS-FNB) for solid pancreatic lesions have been inconclusive with no clear superiority. The aim of this meta-analysis was to compare the diagnostic accuracy and safety between the two sampling techniques. METHODS: We performed a systematic search of randomized controlled trials published between 2012 and 2019. The primary outcome was overall diagnostic accuracy. Secondary outcomes included adverse event rates, cytopathologic and histopathologic accuracy, and the mean number of passes required to obtain adequate tissue between FNA and FNB needles. Fixed and random effect models with pooled estimates of target outcomes were developed. RESULTS: Eleven studies involving 1,365 participants were included for analysis. When compared to FNB, FNA had a significant reduction in diagnostic accuracy (81% and 87%, p=0.005). In addition, FNA provided reduced cytopathologic accuracy (82% and 89%, p=0.04) and an increased number of mean passes required compared to FNB (2.3 and 1.6, respectively, p<0.0001). There was no difference in adverse event rate between FNA and FNB needles (1.8% and 2.3% respectively, p=0.64). CONCLUSIONS: FNB provides superior diagnostic accuracy without compromising safety when compared to FNA. FNB should be readily considered by endosonographers when evaluating solid pancreatic masses.
format Online
Article
Text
id pubmed-8039752
institution National Center for Biotechnology Information
language English
publishDate 2021
publisher Korean Society of Gastrointestinal Endoscopy
record_format MEDLINE/PubMed
spelling pubmed-80397522021-04-19 Endoscopic Ultrasound-Guided Fine Needle Biopsy Needles Provide Higher Diagnostic Yield Compared to Endoscopic Ultrasound-Guided Fine Needle Aspiration Needles When Sampling Solid Pancreatic Lesions: A Meta-Analysis Renelus, Benjamin D. Jamorabo, Daniel S. Boston, Iman Briggs, William M. Poneros, John M. Clin Endosc Original Article BACKGROUND/AIMS: Studies comparing the utility of endoscopic ultrasound-guided fine needle aspiration (EUS-FNA) and endoscopic ultrasound-guided fine needle biopsy (EUS-FNB) for solid pancreatic lesions have been inconclusive with no clear superiority. The aim of this meta-analysis was to compare the diagnostic accuracy and safety between the two sampling techniques. METHODS: We performed a systematic search of randomized controlled trials published between 2012 and 2019. The primary outcome was overall diagnostic accuracy. Secondary outcomes included adverse event rates, cytopathologic and histopathologic accuracy, and the mean number of passes required to obtain adequate tissue between FNA and FNB needles. Fixed and random effect models with pooled estimates of target outcomes were developed. RESULTS: Eleven studies involving 1,365 participants were included for analysis. When compared to FNB, FNA had a significant reduction in diagnostic accuracy (81% and 87%, p=0.005). In addition, FNA provided reduced cytopathologic accuracy (82% and 89%, p=0.04) and an increased number of mean passes required compared to FNB (2.3 and 1.6, respectively, p<0.0001). There was no difference in adverse event rate between FNA and FNB needles (1.8% and 2.3% respectively, p=0.64). CONCLUSIONS: FNB provides superior diagnostic accuracy without compromising safety when compared to FNA. FNB should be readily considered by endosonographers when evaluating solid pancreatic masses. Korean Society of Gastrointestinal Endoscopy 2021-03 2020-08-31 /pmc/articles/PMC8039752/ /pubmed/32892519 http://dx.doi.org/10.5946/ce.2020.101 Text en Copyright © 2021 Korean Society of Gastrointestinal Endoscopy https://creativecommons.org/licenses/by-nc/3.0/This is an Open Access article distributed under the terms of the Creative Commons Attribution Non-Commercial License (http://creativecommons.org/licenses/by-nc/3.0/ (https://creativecommons.org/licenses/by-nc/3.0/) ) which permits unrestricted non-commercial use, distribution, and reproduction in any medium, provided the original work is properly cited.
spellingShingle Original Article
Renelus, Benjamin D.
Jamorabo, Daniel S.
Boston, Iman
Briggs, William M.
Poneros, John M.
Endoscopic Ultrasound-Guided Fine Needle Biopsy Needles Provide Higher Diagnostic Yield Compared to Endoscopic Ultrasound-Guided Fine Needle Aspiration Needles When Sampling Solid Pancreatic Lesions: A Meta-Analysis
title Endoscopic Ultrasound-Guided Fine Needle Biopsy Needles Provide Higher Diagnostic Yield Compared to Endoscopic Ultrasound-Guided Fine Needle Aspiration Needles When Sampling Solid Pancreatic Lesions: A Meta-Analysis
title_full Endoscopic Ultrasound-Guided Fine Needle Biopsy Needles Provide Higher Diagnostic Yield Compared to Endoscopic Ultrasound-Guided Fine Needle Aspiration Needles When Sampling Solid Pancreatic Lesions: A Meta-Analysis
title_fullStr Endoscopic Ultrasound-Guided Fine Needle Biopsy Needles Provide Higher Diagnostic Yield Compared to Endoscopic Ultrasound-Guided Fine Needle Aspiration Needles When Sampling Solid Pancreatic Lesions: A Meta-Analysis
title_full_unstemmed Endoscopic Ultrasound-Guided Fine Needle Biopsy Needles Provide Higher Diagnostic Yield Compared to Endoscopic Ultrasound-Guided Fine Needle Aspiration Needles When Sampling Solid Pancreatic Lesions: A Meta-Analysis
title_short Endoscopic Ultrasound-Guided Fine Needle Biopsy Needles Provide Higher Diagnostic Yield Compared to Endoscopic Ultrasound-Guided Fine Needle Aspiration Needles When Sampling Solid Pancreatic Lesions: A Meta-Analysis
title_sort endoscopic ultrasound-guided fine needle biopsy needles provide higher diagnostic yield compared to endoscopic ultrasound-guided fine needle aspiration needles when sampling solid pancreatic lesions: a meta-analysis
topic Original Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8039752/
https://www.ncbi.nlm.nih.gov/pubmed/32892519
http://dx.doi.org/10.5946/ce.2020.101
work_keys_str_mv AT renelusbenjamind endoscopicultrasoundguidedfineneedlebiopsyneedlesprovidehigherdiagnosticyieldcomparedtoendoscopicultrasoundguidedfineneedleaspirationneedleswhensamplingsolidpancreaticlesionsametaanalysis
AT jamorabodaniels endoscopicultrasoundguidedfineneedlebiopsyneedlesprovidehigherdiagnosticyieldcomparedtoendoscopicultrasoundguidedfineneedleaspirationneedleswhensamplingsolidpancreaticlesionsametaanalysis
AT bostoniman endoscopicultrasoundguidedfineneedlebiopsyneedlesprovidehigherdiagnosticyieldcomparedtoendoscopicultrasoundguidedfineneedleaspirationneedleswhensamplingsolidpancreaticlesionsametaanalysis
AT briggswilliamm endoscopicultrasoundguidedfineneedlebiopsyneedlesprovidehigherdiagnosticyieldcomparedtoendoscopicultrasoundguidedfineneedleaspirationneedleswhensamplingsolidpancreaticlesionsametaanalysis
AT ponerosjohnm endoscopicultrasoundguidedfineneedlebiopsyneedlesprovidehigherdiagnosticyieldcomparedtoendoscopicultrasoundguidedfineneedleaspirationneedleswhensamplingsolidpancreaticlesionsametaanalysis