Comparison Between a Standard and SalivaDirect RNA Extraction Protocol for Molecular Diagnosis of SARS-CoV-2 Using Nasopharyngeal Swab and Saliva Clinical Samples
During the COVID-19 pandemic, a certified laboratory of Tamaulipas, Mexico has processed over 100,000 samples of COVID-19 suspected patients, working a minimum of 100 tests daily. Thus, it would be beneficial for such certified laboratories nationwide to reduce the time and cost involved in performi...
Autores principales: | , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Frontiers Media S.A.
2021
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8040950/ https://www.ncbi.nlm.nih.gov/pubmed/33855014 http://dx.doi.org/10.3389/fbioe.2021.638902 |
_version_ | 1783677865440575488 |
---|---|
author | Rodríguez Flores, Sofía N. Rodríguez-Martínez, Luis Mario Reyes-Berrones, Bernardita L. Fernández-Santos, Nadia A. Sierra-Moncada, Elthon J. Rodríguez-Pérez, Mario A. |
author_facet | Rodríguez Flores, Sofía N. Rodríguez-Martínez, Luis Mario Reyes-Berrones, Bernardita L. Fernández-Santos, Nadia A. Sierra-Moncada, Elthon J. Rodríguez-Pérez, Mario A. |
author_sort | Rodríguez Flores, Sofía N. |
collection | PubMed |
description | During the COVID-19 pandemic, a certified laboratory of Tamaulipas, Mexico has processed over 100,000 samples of COVID-19 suspected patients, working a minimum of 100 tests daily. Thus, it would be beneficial for such certified laboratories nationwide to reduce the time and cost involved in performing the diagnosis of COVID-19, from sample collection, transportation to local lab, processing of samples, and data acquisition. Here, 30 nasopharyngeal swab and saliva samples from the same COVID-19 individuals were assessed by a standard nucleic acid extraction protocol, including protein lysis with proteinase K followed by binding to column, washing, and elution, and by the SalivaDirect protocol based on protein lysis, skipping the other steps to reduce processing time and costs. The genomic RNA was amplified using a SARS-CoV-2 Real-Time PCR kit. A variation (P > 0.05) in the 95% CIs = 72.6%–96.7% was noted by using the SalivaDirect protocol and saliva samples (sensitivity of 88.2%) in comparison to those of standard protocol with oropharyngeal swab samples (95% CIs = 97.5%–100%; sensitivity of 100%) as reported elsewhere. However, when using nasopharyngeal swab samples in the SalivaDirect protocol (sensitivity of 93.6%; 95% CIs = 79.2%–99.2%), it was in concordance (P < 0.05) with those of the standard one. The logical explanation to this was that two samples with Ct values of 38, and 40 cycles for gene E produced two false negatives in the SalivaDirect protocol in relation to the standard one; thus, there was a reduction of the sensitivity of 6.4% in the overall assay performance. |
format | Online Article Text |
id | pubmed-8040950 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2021 |
publisher | Frontiers Media S.A. |
record_format | MEDLINE/PubMed |
spelling | pubmed-80409502021-04-13 Comparison Between a Standard and SalivaDirect RNA Extraction Protocol for Molecular Diagnosis of SARS-CoV-2 Using Nasopharyngeal Swab and Saliva Clinical Samples Rodríguez Flores, Sofía N. Rodríguez-Martínez, Luis Mario Reyes-Berrones, Bernardita L. Fernández-Santos, Nadia A. Sierra-Moncada, Elthon J. Rodríguez-Pérez, Mario A. Front Bioeng Biotechnol Bioengineering and Biotechnology During the COVID-19 pandemic, a certified laboratory of Tamaulipas, Mexico has processed over 100,000 samples of COVID-19 suspected patients, working a minimum of 100 tests daily. Thus, it would be beneficial for such certified laboratories nationwide to reduce the time and cost involved in performing the diagnosis of COVID-19, from sample collection, transportation to local lab, processing of samples, and data acquisition. Here, 30 nasopharyngeal swab and saliva samples from the same COVID-19 individuals were assessed by a standard nucleic acid extraction protocol, including protein lysis with proteinase K followed by binding to column, washing, and elution, and by the SalivaDirect protocol based on protein lysis, skipping the other steps to reduce processing time and costs. The genomic RNA was amplified using a SARS-CoV-2 Real-Time PCR kit. A variation (P > 0.05) in the 95% CIs = 72.6%–96.7% was noted by using the SalivaDirect protocol and saliva samples (sensitivity of 88.2%) in comparison to those of standard protocol with oropharyngeal swab samples (95% CIs = 97.5%–100%; sensitivity of 100%) as reported elsewhere. However, when using nasopharyngeal swab samples in the SalivaDirect protocol (sensitivity of 93.6%; 95% CIs = 79.2%–99.2%), it was in concordance (P < 0.05) with those of the standard one. The logical explanation to this was that two samples with Ct values of 38, and 40 cycles for gene E produced two false negatives in the SalivaDirect protocol in relation to the standard one; thus, there was a reduction of the sensitivity of 6.4% in the overall assay performance. Frontiers Media S.A. 2021-03-29 /pmc/articles/PMC8040950/ /pubmed/33855014 http://dx.doi.org/10.3389/fbioe.2021.638902 Text en Copyright © 2021 Rodríguez Flores, Rodríguez-Martínez, Reyes-Berrones, Fernández-Santos, Sierra-Moncada and Rodríguez-Pérez. https://creativecommons.org/licenses/by/4.0/This is an open-access article distributed under the terms of the Creative Commons Attribution License (CC BY). The use, distribution or reproduction in other forums is permitted, provided the original author(s) and the copyright owner(s) are credited and that the original publication in this journal is cited, in accordance with accepted academic practice. No use, distribution or reproduction is permitted which does not comply with these terms. |
spellingShingle | Bioengineering and Biotechnology Rodríguez Flores, Sofía N. Rodríguez-Martínez, Luis Mario Reyes-Berrones, Bernardita L. Fernández-Santos, Nadia A. Sierra-Moncada, Elthon J. Rodríguez-Pérez, Mario A. Comparison Between a Standard and SalivaDirect RNA Extraction Protocol for Molecular Diagnosis of SARS-CoV-2 Using Nasopharyngeal Swab and Saliva Clinical Samples |
title | Comparison Between a Standard and SalivaDirect RNA Extraction Protocol for Molecular Diagnosis of SARS-CoV-2 Using Nasopharyngeal Swab and Saliva Clinical Samples |
title_full | Comparison Between a Standard and SalivaDirect RNA Extraction Protocol for Molecular Diagnosis of SARS-CoV-2 Using Nasopharyngeal Swab and Saliva Clinical Samples |
title_fullStr | Comparison Between a Standard and SalivaDirect RNA Extraction Protocol for Molecular Diagnosis of SARS-CoV-2 Using Nasopharyngeal Swab and Saliva Clinical Samples |
title_full_unstemmed | Comparison Between a Standard and SalivaDirect RNA Extraction Protocol for Molecular Diagnosis of SARS-CoV-2 Using Nasopharyngeal Swab and Saliva Clinical Samples |
title_short | Comparison Between a Standard and SalivaDirect RNA Extraction Protocol for Molecular Diagnosis of SARS-CoV-2 Using Nasopharyngeal Swab and Saliva Clinical Samples |
title_sort | comparison between a standard and salivadirect rna extraction protocol for molecular diagnosis of sars-cov-2 using nasopharyngeal swab and saliva clinical samples |
topic | Bioengineering and Biotechnology |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8040950/ https://www.ncbi.nlm.nih.gov/pubmed/33855014 http://dx.doi.org/10.3389/fbioe.2021.638902 |
work_keys_str_mv | AT rodriguezfloressofian comparisonbetweenastandardandsalivadirectrnaextractionprotocolformoleculardiagnosisofsarscov2usingnasopharyngealswabandsalivaclinicalsamples AT rodriguezmartinezluismario comparisonbetweenastandardandsalivadirectrnaextractionprotocolformoleculardiagnosisofsarscov2usingnasopharyngealswabandsalivaclinicalsamples AT reyesberronesbernardital comparisonbetweenastandardandsalivadirectrnaextractionprotocolformoleculardiagnosisofsarscov2usingnasopharyngealswabandsalivaclinicalsamples AT fernandezsantosnadiaa comparisonbetweenastandardandsalivadirectrnaextractionprotocolformoleculardiagnosisofsarscov2usingnasopharyngealswabandsalivaclinicalsamples AT sierramoncadaelthonj comparisonbetweenastandardandsalivadirectrnaextractionprotocolformoleculardiagnosisofsarscov2usingnasopharyngealswabandsalivaclinicalsamples AT rodriguezperezmarioa comparisonbetweenastandardandsalivadirectrnaextractionprotocolformoleculardiagnosisofsarscov2usingnasopharyngealswabandsalivaclinicalsamples |