Establishment of reference intervals for Platelet Function Analyzer -100 closure time in Algerian adults

INTRODUCTION: The Platelet Function Analyzer-100 (PFA-100) is a point of care instrument that simulates plug formation under high shear flow. The PFA-100 measures the time required to occlude the aperture in a biochemically active cartridge and is expressed in a term of closure time (CT). In Algeria...

Descripción completa

Detalles Bibliográficos
Autores principales: Belkacemi, Malika, Merad, Yassine, Merbouh, Mohamed Amine
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Public Library of Science 2021
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8041198/
https://www.ncbi.nlm.nih.gov/pubmed/33844690
http://dx.doi.org/10.1371/journal.pone.0249402
_version_ 1783677897239691264
author Belkacemi, Malika
Merad, Yassine
Merbouh, Mohamed Amine
author_facet Belkacemi, Malika
Merad, Yassine
Merbouh, Mohamed Amine
author_sort Belkacemi, Malika
collection PubMed
description INTRODUCTION: The Platelet Function Analyzer-100 (PFA-100) is a point of care instrument that simulates plug formation under high shear flow. The PFA-100 measures the time required to occlude the aperture in a biochemically active cartridge and is expressed in a term of closure time (CT). In Algeria, the reference values used in clinical laboratories are of Western origin. However, ethnic, genetic, dietary environmental, and diet differences between populations may affect reference intervals. We established the reference intervals of PFA-100 closure times in healthy Algerian adults according to the International Federation of Clinical Chemistry method, and we compared them with those of Western and Asian countries. MATERIAL AND METHODS: We enrolled 303 healthy blood donors in the study. 218 subjects met inclusion criteria. We analyzed the blood sample on the PFA-100 for CT with both the collagen epinephrine and collagen ADP cartridges. RESULTS: The reference intervals of PFA-100 collagen epinephrine CT and PFA-100 collagen ADP CT were 91–207 seconds and 71–144 seconds, respectively. Compared to Western and Asian populations, there were significant differences. The upper limits of CTs were higher for Algerians in this study. Our findings show that many healthy Algerians would be incorrectly identified as having a primary hemostasis abnormality according to the reference intervals of the manufacturer and scientific literature. CONCLUSION: This report provides the first reference intervals for PFA-100 CTs in healthy Algerian adults. These results improve the accuracy of diagnosis and patient care in Algeria.
format Online
Article
Text
id pubmed-8041198
institution National Center for Biotechnology Information
language English
publishDate 2021
publisher Public Library of Science
record_format MEDLINE/PubMed
spelling pubmed-80411982021-04-20 Establishment of reference intervals for Platelet Function Analyzer -100 closure time in Algerian adults Belkacemi, Malika Merad, Yassine Merbouh, Mohamed Amine PLoS One Research Article INTRODUCTION: The Platelet Function Analyzer-100 (PFA-100) is a point of care instrument that simulates plug formation under high shear flow. The PFA-100 measures the time required to occlude the aperture in a biochemically active cartridge and is expressed in a term of closure time (CT). In Algeria, the reference values used in clinical laboratories are of Western origin. However, ethnic, genetic, dietary environmental, and diet differences between populations may affect reference intervals. We established the reference intervals of PFA-100 closure times in healthy Algerian adults according to the International Federation of Clinical Chemistry method, and we compared them with those of Western and Asian countries. MATERIAL AND METHODS: We enrolled 303 healthy blood donors in the study. 218 subjects met inclusion criteria. We analyzed the blood sample on the PFA-100 for CT with both the collagen epinephrine and collagen ADP cartridges. RESULTS: The reference intervals of PFA-100 collagen epinephrine CT and PFA-100 collagen ADP CT were 91–207 seconds and 71–144 seconds, respectively. Compared to Western and Asian populations, there were significant differences. The upper limits of CTs were higher for Algerians in this study. Our findings show that many healthy Algerians would be incorrectly identified as having a primary hemostasis abnormality according to the reference intervals of the manufacturer and scientific literature. CONCLUSION: This report provides the first reference intervals for PFA-100 CTs in healthy Algerian adults. These results improve the accuracy of diagnosis and patient care in Algeria. Public Library of Science 2021-04-12 /pmc/articles/PMC8041198/ /pubmed/33844690 http://dx.doi.org/10.1371/journal.pone.0249402 Text en © 2021 Belkacemi et al https://creativecommons.org/licenses/by/4.0/This is an open access article distributed under the terms of the Creative Commons Attribution License (https://creativecommons.org/licenses/by/4.0/) , which permits unrestricted use, distribution, and reproduction in any medium, provided the original author and source are credited.
spellingShingle Research Article
Belkacemi, Malika
Merad, Yassine
Merbouh, Mohamed Amine
Establishment of reference intervals for Platelet Function Analyzer -100 closure time in Algerian adults
title Establishment of reference intervals for Platelet Function Analyzer -100 closure time in Algerian adults
title_full Establishment of reference intervals for Platelet Function Analyzer -100 closure time in Algerian adults
title_fullStr Establishment of reference intervals for Platelet Function Analyzer -100 closure time in Algerian adults
title_full_unstemmed Establishment of reference intervals for Platelet Function Analyzer -100 closure time in Algerian adults
title_short Establishment of reference intervals for Platelet Function Analyzer -100 closure time in Algerian adults
title_sort establishment of reference intervals for platelet function analyzer -100 closure time in algerian adults
topic Research Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8041198/
https://www.ncbi.nlm.nih.gov/pubmed/33844690
http://dx.doi.org/10.1371/journal.pone.0249402
work_keys_str_mv AT belkacemimalika establishmentofreferenceintervalsforplateletfunctionanalyzer100closuretimeinalgerianadults
AT meradyassine establishmentofreferenceintervalsforplateletfunctionanalyzer100closuretimeinalgerianadults
AT merbouhmohamedamine establishmentofreferenceintervalsforplateletfunctionanalyzer100closuretimeinalgerianadults