Cargando…

Reliability of Imageless Computer-Assisted Navigation for Femoral Rotational Alignment in Total Knee Arthroplasty

INTRODUCTION: The aim of this study was to evaluate the reliability of the femoral component rotation on intra-operative data recorded in a computer-assisted navigation system (CAN-FRA) compared with the post-operative femoral component rotation observed on computed tomography (CT-FRA). MATERIAL AND...

Descripción completa

Detalles Bibliográficos
Autores principales: Leelasestaporn, C, Thuwapitchayanant, M, Sirithanapipat, P, Sa-ngasoongsong, P, Ruengsilsuwit, P
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Malaysian Orthopaedic Association 2021
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8043641/
https://www.ncbi.nlm.nih.gov/pubmed/33880152
http://dx.doi.org/10.5704/MOJ.2103.012
_version_ 1783678343506296832
author Leelasestaporn, C
Thuwapitchayanant, M
Sirithanapipat, P
Sa-ngasoongsong, P
Ruengsilsuwit, P
author_facet Leelasestaporn, C
Thuwapitchayanant, M
Sirithanapipat, P
Sa-ngasoongsong, P
Ruengsilsuwit, P
author_sort Leelasestaporn, C
collection PubMed
description INTRODUCTION: The aim of this study was to evaluate the reliability of the femoral component rotation on intra-operative data recorded in a computer-assisted navigation system (CAN-FRA) compared with the post-operative femoral component rotation observed on computed tomography (CT-FRA). MATERIAL AND METHOD: Computer-assisted total knee arthroplasty (TKA) or primary osteoarthritis of the knee was performed in 51 knees in 36 patients with a mean age of 69.51 years. All procedures were performed by a single surgeon using the same implant design. The intraclass correlation coefficient (ICC) was used to compare the intra-operative CAN-FRA with the post-operative CT-FRA. The angle between the anatomical epicondylar axis and the posterior condylar axis of the implant (CT-FRA) was measured at two separate timepoints by three observers who were blinded to the intra-operative CAN-FRA. Internal rotation was defined as rotation in the negative direction, while external rotation was defined as positive. RESULTS: The mean intra-operative CAN-FRA was 0.1° ± 2.8° (range -5.0° to 5.5°). The mean post-operative CT-FRA was -1.3° ± 2.1° (range -4.6° to 4.4°). The mean difference between the CAN-FRA and the CT-FRA was -1.3° ± 2.2° (range -7.9° to 2.4°). The respective ICC values for the three observers were 0.92, 0.94, and 0.93, while the respective intra-observer coefficients were 0.91, 0.85, and 0.90. The ICC for the intra-operative CAN-FRA versus the post-operative CT-FRA was 0.71. CONCLUSION: This study shows that using a computer-assisted navigation system in TKA achieves reliable results and helps to achieve optimal positioning of the femoral component and rotation alignment correction.
format Online
Article
Text
id pubmed-8043641
institution National Center for Biotechnology Information
language English
publishDate 2021
publisher Malaysian Orthopaedic Association
record_format MEDLINE/PubMed
spelling pubmed-80436412021-04-19 Reliability of Imageless Computer-Assisted Navigation for Femoral Rotational Alignment in Total Knee Arthroplasty Leelasestaporn, C Thuwapitchayanant, M Sirithanapipat, P Sa-ngasoongsong, P Ruengsilsuwit, P Malays Orthop J Original Study INTRODUCTION: The aim of this study was to evaluate the reliability of the femoral component rotation on intra-operative data recorded in a computer-assisted navigation system (CAN-FRA) compared with the post-operative femoral component rotation observed on computed tomography (CT-FRA). MATERIAL AND METHOD: Computer-assisted total knee arthroplasty (TKA) or primary osteoarthritis of the knee was performed in 51 knees in 36 patients with a mean age of 69.51 years. All procedures were performed by a single surgeon using the same implant design. The intraclass correlation coefficient (ICC) was used to compare the intra-operative CAN-FRA with the post-operative CT-FRA. The angle between the anatomical epicondylar axis and the posterior condylar axis of the implant (CT-FRA) was measured at two separate timepoints by three observers who were blinded to the intra-operative CAN-FRA. Internal rotation was defined as rotation in the negative direction, while external rotation was defined as positive. RESULTS: The mean intra-operative CAN-FRA was 0.1° ± 2.8° (range -5.0° to 5.5°). The mean post-operative CT-FRA was -1.3° ± 2.1° (range -4.6° to 4.4°). The mean difference between the CAN-FRA and the CT-FRA was -1.3° ± 2.2° (range -7.9° to 2.4°). The respective ICC values for the three observers were 0.92, 0.94, and 0.93, while the respective intra-observer coefficients were 0.91, 0.85, and 0.90. The ICC for the intra-operative CAN-FRA versus the post-operative CT-FRA was 0.71. CONCLUSION: This study shows that using a computer-assisted navigation system in TKA achieves reliable results and helps to achieve optimal positioning of the femoral component and rotation alignment correction. Malaysian Orthopaedic Association 2021-03 /pmc/articles/PMC8043641/ /pubmed/33880152 http://dx.doi.org/10.5704/MOJ.2103.012 Text en © 2021 Malaysian Orthopaedic Association MOA. All Rights Reserved https://creativecommons.org/licenses/by/3.0/This is an open-access article distributed under the terms of the Creative Commons Attribution License, which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited
spellingShingle Original Study
Leelasestaporn, C
Thuwapitchayanant, M
Sirithanapipat, P
Sa-ngasoongsong, P
Ruengsilsuwit, P
Reliability of Imageless Computer-Assisted Navigation for Femoral Rotational Alignment in Total Knee Arthroplasty
title Reliability of Imageless Computer-Assisted Navigation for Femoral Rotational Alignment in Total Knee Arthroplasty
title_full Reliability of Imageless Computer-Assisted Navigation for Femoral Rotational Alignment in Total Knee Arthroplasty
title_fullStr Reliability of Imageless Computer-Assisted Navigation for Femoral Rotational Alignment in Total Knee Arthroplasty
title_full_unstemmed Reliability of Imageless Computer-Assisted Navigation for Femoral Rotational Alignment in Total Knee Arthroplasty
title_short Reliability of Imageless Computer-Assisted Navigation for Femoral Rotational Alignment in Total Knee Arthroplasty
title_sort reliability of imageless computer-assisted navigation for femoral rotational alignment in total knee arthroplasty
topic Original Study
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8043641/
https://www.ncbi.nlm.nih.gov/pubmed/33880152
http://dx.doi.org/10.5704/MOJ.2103.012
work_keys_str_mv AT leelasestapornc reliabilityofimagelesscomputerassistednavigationforfemoralrotationalalignmentintotalkneearthroplasty
AT thuwapitchayanantm reliabilityofimagelesscomputerassistednavigationforfemoralrotationalalignmentintotalkneearthroplasty
AT sirithanapipatp reliabilityofimagelesscomputerassistednavigationforfemoralrotationalalignmentintotalkneearthroplasty
AT sangasoongsongp reliabilityofimagelesscomputerassistednavigationforfemoralrotationalalignmentintotalkneearthroplasty
AT ruengsilsuwitp reliabilityofimagelesscomputerassistednavigationforfemoralrotationalalignmentintotalkneearthroplasty