Cargando…
Reliability of Imageless Computer-Assisted Navigation for Femoral Rotational Alignment in Total Knee Arthroplasty
INTRODUCTION: The aim of this study was to evaluate the reliability of the femoral component rotation on intra-operative data recorded in a computer-assisted navigation system (CAN-FRA) compared with the post-operative femoral component rotation observed on computed tomography (CT-FRA). MATERIAL AND...
Autores principales: | , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Malaysian Orthopaedic Association
2021
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8043641/ https://www.ncbi.nlm.nih.gov/pubmed/33880152 http://dx.doi.org/10.5704/MOJ.2103.012 |
_version_ | 1783678343506296832 |
---|---|
author | Leelasestaporn, C Thuwapitchayanant, M Sirithanapipat, P Sa-ngasoongsong, P Ruengsilsuwit, P |
author_facet | Leelasestaporn, C Thuwapitchayanant, M Sirithanapipat, P Sa-ngasoongsong, P Ruengsilsuwit, P |
author_sort | Leelasestaporn, C |
collection | PubMed |
description | INTRODUCTION: The aim of this study was to evaluate the reliability of the femoral component rotation on intra-operative data recorded in a computer-assisted navigation system (CAN-FRA) compared with the post-operative femoral component rotation observed on computed tomography (CT-FRA). MATERIAL AND METHOD: Computer-assisted total knee arthroplasty (TKA) or primary osteoarthritis of the knee was performed in 51 knees in 36 patients with a mean age of 69.51 years. All procedures were performed by a single surgeon using the same implant design. The intraclass correlation coefficient (ICC) was used to compare the intra-operative CAN-FRA with the post-operative CT-FRA. The angle between the anatomical epicondylar axis and the posterior condylar axis of the implant (CT-FRA) was measured at two separate timepoints by three observers who were blinded to the intra-operative CAN-FRA. Internal rotation was defined as rotation in the negative direction, while external rotation was defined as positive. RESULTS: The mean intra-operative CAN-FRA was 0.1° ± 2.8° (range -5.0° to 5.5°). The mean post-operative CT-FRA was -1.3° ± 2.1° (range -4.6° to 4.4°). The mean difference between the CAN-FRA and the CT-FRA was -1.3° ± 2.2° (range -7.9° to 2.4°). The respective ICC values for the three observers were 0.92, 0.94, and 0.93, while the respective intra-observer coefficients were 0.91, 0.85, and 0.90. The ICC for the intra-operative CAN-FRA versus the post-operative CT-FRA was 0.71. CONCLUSION: This study shows that using a computer-assisted navigation system in TKA achieves reliable results and helps to achieve optimal positioning of the femoral component and rotation alignment correction. |
format | Online Article Text |
id | pubmed-8043641 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2021 |
publisher | Malaysian Orthopaedic Association |
record_format | MEDLINE/PubMed |
spelling | pubmed-80436412021-04-19 Reliability of Imageless Computer-Assisted Navigation for Femoral Rotational Alignment in Total Knee Arthroplasty Leelasestaporn, C Thuwapitchayanant, M Sirithanapipat, P Sa-ngasoongsong, P Ruengsilsuwit, P Malays Orthop J Original Study INTRODUCTION: The aim of this study was to evaluate the reliability of the femoral component rotation on intra-operative data recorded in a computer-assisted navigation system (CAN-FRA) compared with the post-operative femoral component rotation observed on computed tomography (CT-FRA). MATERIAL AND METHOD: Computer-assisted total knee arthroplasty (TKA) or primary osteoarthritis of the knee was performed in 51 knees in 36 patients with a mean age of 69.51 years. All procedures were performed by a single surgeon using the same implant design. The intraclass correlation coefficient (ICC) was used to compare the intra-operative CAN-FRA with the post-operative CT-FRA. The angle between the anatomical epicondylar axis and the posterior condylar axis of the implant (CT-FRA) was measured at two separate timepoints by three observers who were blinded to the intra-operative CAN-FRA. Internal rotation was defined as rotation in the negative direction, while external rotation was defined as positive. RESULTS: The mean intra-operative CAN-FRA was 0.1° ± 2.8° (range -5.0° to 5.5°). The mean post-operative CT-FRA was -1.3° ± 2.1° (range -4.6° to 4.4°). The mean difference between the CAN-FRA and the CT-FRA was -1.3° ± 2.2° (range -7.9° to 2.4°). The respective ICC values for the three observers were 0.92, 0.94, and 0.93, while the respective intra-observer coefficients were 0.91, 0.85, and 0.90. The ICC for the intra-operative CAN-FRA versus the post-operative CT-FRA was 0.71. CONCLUSION: This study shows that using a computer-assisted navigation system in TKA achieves reliable results and helps to achieve optimal positioning of the femoral component and rotation alignment correction. Malaysian Orthopaedic Association 2021-03 /pmc/articles/PMC8043641/ /pubmed/33880152 http://dx.doi.org/10.5704/MOJ.2103.012 Text en © 2021 Malaysian Orthopaedic Association MOA. All Rights Reserved https://creativecommons.org/licenses/by/3.0/This is an open-access article distributed under the terms of the Creative Commons Attribution License, which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited |
spellingShingle | Original Study Leelasestaporn, C Thuwapitchayanant, M Sirithanapipat, P Sa-ngasoongsong, P Ruengsilsuwit, P Reliability of Imageless Computer-Assisted Navigation for Femoral Rotational Alignment in Total Knee Arthroplasty |
title | Reliability of Imageless Computer-Assisted Navigation for Femoral Rotational Alignment in Total Knee Arthroplasty |
title_full | Reliability of Imageless Computer-Assisted Navigation for Femoral Rotational Alignment in Total Knee Arthroplasty |
title_fullStr | Reliability of Imageless Computer-Assisted Navigation for Femoral Rotational Alignment in Total Knee Arthroplasty |
title_full_unstemmed | Reliability of Imageless Computer-Assisted Navigation for Femoral Rotational Alignment in Total Knee Arthroplasty |
title_short | Reliability of Imageless Computer-Assisted Navigation for Femoral Rotational Alignment in Total Knee Arthroplasty |
title_sort | reliability of imageless computer-assisted navigation for femoral rotational alignment in total knee arthroplasty |
topic | Original Study |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8043641/ https://www.ncbi.nlm.nih.gov/pubmed/33880152 http://dx.doi.org/10.5704/MOJ.2103.012 |
work_keys_str_mv | AT leelasestapornc reliabilityofimagelesscomputerassistednavigationforfemoralrotationalalignmentintotalkneearthroplasty AT thuwapitchayanantm reliabilityofimagelesscomputerassistednavigationforfemoralrotationalalignmentintotalkneearthroplasty AT sirithanapipatp reliabilityofimagelesscomputerassistednavigationforfemoralrotationalalignmentintotalkneearthroplasty AT sangasoongsongp reliabilityofimagelesscomputerassistednavigationforfemoralrotationalalignmentintotalkneearthroplasty AT ruengsilsuwitp reliabilityofimagelesscomputerassistednavigationforfemoralrotationalalignmentintotalkneearthroplasty |