Cargando…

Teleguided self-ultrasound scanning for longitudinal monitoring of muscle mass during spaceflight

Loss of muscle mass is a major concern for long duration spaceflight. However, due to the need for specialized equipment, muscle size has only been assessed before and after spaceflight where ~20% loss is observed. Here, we demonstrate the utility of teleguided self-ultrasound scanning (Tele-SUS) to...

Descripción completa

Detalles Bibliográficos
Autores principales: Scott, Jessica M., Downs, Meghan, Martin, David S., Hougland, Erik, Sarmiento, Laura, Arzeno, Natalia, Pettit, Donald R., Ploutz-Snyder, Robert, Cunningham, David, Jones, Lee W., Do, Richard, Ploutz-Snyder, Lori
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Elsevier 2021
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8047175/
https://www.ncbi.nlm.nih.gov/pubmed/33870138
http://dx.doi.org/10.1016/j.isci.2021.102344
_version_ 1783678993259560960
author Scott, Jessica M.
Downs, Meghan
Martin, David S.
Hougland, Erik
Sarmiento, Laura
Arzeno, Natalia
Pettit, Donald R.
Ploutz-Snyder, Robert
Cunningham, David
Jones, Lee W.
Do, Richard
Ploutz-Snyder, Lori
author_facet Scott, Jessica M.
Downs, Meghan
Martin, David S.
Hougland, Erik
Sarmiento, Laura
Arzeno, Natalia
Pettit, Donald R.
Ploutz-Snyder, Robert
Cunningham, David
Jones, Lee W.
Do, Richard
Ploutz-Snyder, Lori
author_sort Scott, Jessica M.
collection PubMed
description Loss of muscle mass is a major concern for long duration spaceflight. However, due to the need for specialized equipment, muscle size has only been assessed before and after spaceflight where ~20% loss is observed. Here, we demonstrate the utility of teleguided self-ultrasound scanning (Tele-SUS) to accurately monitor leg muscle size in astronauts during spaceflight. Over an average of 168 ± 57 days of spaceflight, 74 Tele-SUS sessions were performed. There were no significant differences between panoramic ultrasound images obtained by astronauts seven days prior to landing and expert sonographer after flight or between change in muscle size assessed by ultrasound and magnetic resonance imaging. These findings extend the current capabilities of ultrasound imaging to allow self-monitoring of muscle size with remote guidance.
format Online
Article
Text
id pubmed-8047175
institution National Center for Biotechnology Information
language English
publishDate 2021
publisher Elsevier
record_format MEDLINE/PubMed
spelling pubmed-80471752021-04-16 Teleguided self-ultrasound scanning for longitudinal monitoring of muscle mass during spaceflight Scott, Jessica M. Downs, Meghan Martin, David S. Hougland, Erik Sarmiento, Laura Arzeno, Natalia Pettit, Donald R. Ploutz-Snyder, Robert Cunningham, David Jones, Lee W. Do, Richard Ploutz-Snyder, Lori iScience Article Loss of muscle mass is a major concern for long duration spaceflight. However, due to the need for specialized equipment, muscle size has only been assessed before and after spaceflight where ~20% loss is observed. Here, we demonstrate the utility of teleguided self-ultrasound scanning (Tele-SUS) to accurately monitor leg muscle size in astronauts during spaceflight. Over an average of 168 ± 57 days of spaceflight, 74 Tele-SUS sessions were performed. There were no significant differences between panoramic ultrasound images obtained by astronauts seven days prior to landing and expert sonographer after flight or between change in muscle size assessed by ultrasound and magnetic resonance imaging. These findings extend the current capabilities of ultrasound imaging to allow self-monitoring of muscle size with remote guidance. Elsevier 2021-03-21 /pmc/articles/PMC8047175/ /pubmed/33870138 http://dx.doi.org/10.1016/j.isci.2021.102344 Text en © 2021 The Authors https://creativecommons.org/licenses/by-nc-nd/4.0/This is an open access article under the CC BY-NC-ND license (http://creativecommons.org/licenses/by-nc-nd/4.0/).
spellingShingle Article
Scott, Jessica M.
Downs, Meghan
Martin, David S.
Hougland, Erik
Sarmiento, Laura
Arzeno, Natalia
Pettit, Donald R.
Ploutz-Snyder, Robert
Cunningham, David
Jones, Lee W.
Do, Richard
Ploutz-Snyder, Lori
Teleguided self-ultrasound scanning for longitudinal monitoring of muscle mass during spaceflight
title Teleguided self-ultrasound scanning for longitudinal monitoring of muscle mass during spaceflight
title_full Teleguided self-ultrasound scanning for longitudinal monitoring of muscle mass during spaceflight
title_fullStr Teleguided self-ultrasound scanning for longitudinal monitoring of muscle mass during spaceflight
title_full_unstemmed Teleguided self-ultrasound scanning for longitudinal monitoring of muscle mass during spaceflight
title_short Teleguided self-ultrasound scanning for longitudinal monitoring of muscle mass during spaceflight
title_sort teleguided self-ultrasound scanning for longitudinal monitoring of muscle mass during spaceflight
topic Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8047175/
https://www.ncbi.nlm.nih.gov/pubmed/33870138
http://dx.doi.org/10.1016/j.isci.2021.102344
work_keys_str_mv AT scottjessicam teleguidedselfultrasoundscanningforlongitudinalmonitoringofmusclemassduringspaceflight
AT downsmeghan teleguidedselfultrasoundscanningforlongitudinalmonitoringofmusclemassduringspaceflight
AT martindavids teleguidedselfultrasoundscanningforlongitudinalmonitoringofmusclemassduringspaceflight
AT houglanderik teleguidedselfultrasoundscanningforlongitudinalmonitoringofmusclemassduringspaceflight
AT sarmientolaura teleguidedselfultrasoundscanningforlongitudinalmonitoringofmusclemassduringspaceflight
AT arzenonatalia teleguidedselfultrasoundscanningforlongitudinalmonitoringofmusclemassduringspaceflight
AT pettitdonaldr teleguidedselfultrasoundscanningforlongitudinalmonitoringofmusclemassduringspaceflight
AT ploutzsnyderrobert teleguidedselfultrasoundscanningforlongitudinalmonitoringofmusclemassduringspaceflight
AT cunninghamdavid teleguidedselfultrasoundscanningforlongitudinalmonitoringofmusclemassduringspaceflight
AT jonesleew teleguidedselfultrasoundscanningforlongitudinalmonitoringofmusclemassduringspaceflight
AT dorichard teleguidedselfultrasoundscanningforlongitudinalmonitoringofmusclemassduringspaceflight
AT ploutzsnyderlori teleguidedselfultrasoundscanningforlongitudinalmonitoringofmusclemassduringspaceflight