The Association of Central Corneal Thickness and Intraocular Pressure Measures by Non-Contact Tonometry and Goldmann Applanation Tonometry among Glaucoma Patients
BACKGROUND: The aim of this study was to determine whether Central Corneal Thickness (CCT) is associated with intraocular pressure measurement (IOP) with a Non-contact tonometer and the Goldmann applanation tonometer in glaucoma patients. MATERIALS AND METHODS: The study involved two hundred and thi...
Autores principales: | Kyei, Samuel, Assiamah, Frank, Kwarteng, Michael Agyemang, Gboglu, Cynthia Pakyennu |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Research and Publications Office of Jimma University
2020
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8047243/ https://www.ncbi.nlm.nih.gov/pubmed/33883845 http://dx.doi.org/10.4314/ejhs.v30i6.18 |
Ejemplares similares
-
Comparative Assessment of The Goldmann Applanation and Noncontact Tonometers in Intraocular Pressure Measurements in a Sample of Glaucoma Patients in the Cape Coast Metropolis, Ghana
por: Kyei, Samuel, et al.
Publicado: (2020) -
Comparison of rebound tonometry and non-contact airpuff tonometry to Goldmann applanation tonometry
por: Demirci, Goktug, et al.
Publicado: (2019) -
Comparison of Goldmann applanation tonometry and Pascal dynamic contour tonometry in relation to central corneal thickness and corneal curvature
por: Andreanos, Konstantinos, et al.
Publicado: (2016) -
The influence of corneal density and thickness on tonometry measurement with goldmann applanation, non-contact and iCare tonometry methods
por: Lubbad, Ahmed, et al.
Publicado: (2022) -
Tonometry in corneal edema after cataract surgery: dynamic contour tonometry versus Goldmann applanation tonometry
por: Herr, Anne, et al.
Publicado: (2013)